• Modern Log Carbines System 1
  • Modern Log Carbines System 2
  • Modern Log Carbines System 3
Modern Log Carbines

Modern Log Carbines

Ref Price:
get latest price
Loading Port:
Main port, China
Payment Terms:
TT or LC
Min Order Qty:
1 Set m²
Supply Capability:
10 million square meters per year m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications of Modern Log Carbines

The Countryside Log Cabines with a unique style make the people, who are tired of the cold breath of the steel-brick structures, rekindle the elegant, quiet, and natural rural emotional appeal, which has been lost for a long time.

Technology Systems

Steel and Wood Composite Structure System: This system is suitable for 1-3 storeys building

This system is developed by light steel structure and wooden enclosure, connected and fixed by different metal connections and tenon joints method. The stability and the ability of termites preventing of this system are better than wood system. The original nature is also fully displayed by Steel and Wood Composite Structure System with 30% cost reduced. It is especially suitable for vacation hotels, clubs, etc.

 

 

 

Features & Advantages of Modern Log Carbines

1. Seismic and Wind Resistance

Withstand the shock of 9 on the Richter scale.

The dense light gauge steel and column are connected in flexible method with screws and bolts, which can absorb the energy of earthquake. There are fittings between foundation and wall, which are resistant to pull out and shear. The total weight of the house is light, which is only 1/6 of traditional concrete houses. Therefore it has better anti-seismic performance.

Can endure typhoon of 12 levels

There are special fittings among roof, floor, wall and basement. The strong connection can help resist typhoon of 12 levels.

2. Roof Load-bearing and Fireproof

The roof can withstand 1500mm thickness snow.

The structure can be designed according to climate requirements.

Low-rise building fire resistance meet 2.5h (Grade Ⅱ) design standard.

High-rise building fire resistance meet 3h (Grade Ⅰ) design standard.

Wall and floor slab use special technology which can meet 3h refractory limit.

3. Thermal Insulation

The advanced exterior overall thermal insulation meets the updated state energy-saving standards for buildings. It refrains from the cold and thermal bridges phenomenon, and keeps buildings away from damages such as dampness, distortion, mildew and corrosion.

The unique heat reflection and ventilation layer design can make better insulation effects. Temperature can be reduced by five to eight degrees.

4. Sound Insulation

Improved technology on sound insulation and shock absorption meet the state building standards for sound insulation. Special methods are performed, especially towards the audio frequency ranging from 250 to 1000 Hz which is the most sensitive to ears, in order to create a quiet and comfortable living environment.

5. Moisture-proof and Ventilation

There is a gap between wall and roof truss, so the air can flow inside.

There is a one-way ventilation layer in the composite wall, which is able to make the wall ‘breathing’. This means moisture can be reduced inside of the door.

6. Durable

90 years structure safety guarantee

Special coating technology enables the structural materials to have the self-restoration function to prevent rust and corrosion.

Envelope materials using new lightweight building materials to achieve fire resistant,anti-corrosion and anti-moth.

7. Energy Efficient and Environmental Protection

Energy Saving65% -90% energy reduction.

Water Saving The dry construction consumes 10% of water used in traditional construction.

Material Saving 90% of used materials are recycled.

Land Saving The inside usable area increases 10%.

Environment ProtectionPollution–free construction system.

Operation Capability of Modern Log Carbines

Design: Grade A building design certificate

Production: The annual production capacity is 10 million square meters

CAD and CAM software provides the safeguard for the factory mass production and high precision of constructional element, for the convenient installationall of which improve production efficiency.

Construction

Dozens of experienced project teams, hundreds technical guidance engineers

15 days to complete a 100square meters residence.

60 days to complete a 200square meters villa.

100 days to complete a 10000square meters public building.

 

Q: Villa room function how to divide the most appropriate?
Garage, entrance, TV room, restaurant, living room, kitchen, kitchen, breakfast room, bathroom, bedroom, master bedroom, study,
Q: 100 square meters villa size how to calculate?
showing the villa style, and the process is not complicated, Laying roofing materials on a triangular roof truss
Q: How to build self-built villa?
First of all have a legitimate order, the legitimate process is to be approved by the relevant departments reported to build, and so get the relevant documents can be started.
Q: What is the difference between a house and a villa?
the house belongs to the class villa, but the quality of living or lower than the villa, the villa into the door all belong to their own space, and independence. Bungalows generally a layer of 2, there is a flat area
Q: Buy second-hand villa need to pay attention to what?
Whether it is the plot of the internal landscape or landscape and other external resources are the value of product preservation and value-added value
Q: Villa (self-built buildings) feng shui to pay attention to what?
1. Villa houses can not be built on the ridge, or the valley of the entrance, or not only can not get the geographical Fukuzawa
Q: What is the thickness of the villa's floor and the maximum load it can bear?
Said the floor of the bearing capacity of the problem, because the national standard provides the carrying capacity
Q: How much height does the height of the fence of the villa terrace?
Villa terrace fence height should not be less than 1.05m. According to:General Principles for the Design of Civil Buildings GB 50352-2005
Q: What is the height of the villa house?
Villas and other large units of the indoor door selection need to pay attention to the following aspects
Q: What are the characteristics and requirements of villa property management?
the need to pay attention to the quality of services and requirements, and must be much higher than the general residential property
After decades of exploration and development, IN-HOUSE. has gradually formed own intellectual properties and core specialties, possessed professional operation capability, taking environment-protecting and energy-saving houses as main business, and taking development and design light gauge steel structure, building envelop, interior and exterior decorating materials, thermal insulation, water ,heating and electricity system, as well as construction equipment as core technologies.

1. Manufacturer Overview

Location Beijing,China
Year Established 2008
Annual Output Value Above US$1.5 Billion
Main Markets North America, East Europe, Middle East, South Asian, South America, South Pacific Islands and African countries
Company Certifications ISO9001:2008;ISO14001:2004

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port TIANJIN PORT
Export Percentage 40%
No.of Employees in Trade Department 40 People
Language Spoken: English;Chinese
b) Factory Information
Factory Size: Above 150,000 square meters
No. of Production Lines Above 2
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range Average, High

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords