• metal sprinkler hanger and pipe clamps System 1
  • metal sprinkler hanger and pipe clamps System 2
metal sprinkler hanger and pipe clamps

metal sprinkler hanger and pipe clamps

Ref Price:
$0.03 / pc get latest price
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days
Q: How to auto discharge clamp current meter
The clamp type meter works like a transformer.A primary coil is a traverse through a clamp core, equivalent to the primary coil of a transformer with 1 turns, which is a step-up transformer. The two coil and the ammeter used for measurement constitute the two loop. When the wire is AC current through the coil, which is the alternating magnetic field, induction current is generated in the two loop, the size of the current and a current ratio, the equivalent of a number of turns and two coil inverse. The clamp type ammeter is used for measuring high current. If the current is not large enough, the primary wire can increase the number of turns through the clamp table and divide the measured current by the number of turns.
Q: DC screen operation of the display voltage imbalance, what reason, divided into operation, reported
There is a ground fault in the switch or cable or switch. Check the ground.
Q: Can the 5 (20) A meter withstand the current of 30A?
5 (20) A stands for this meter, allowing long running currents not exceeding 20A, instead of representing 20A for a short period of time. As for the meaning of that 5, nor is it representative of the rated current, but should be called the reference current. It is a benchmark used in the inspection and test of electric meters, such as detecting the light load of electric meters. The full load。 Starting current. And so on, that's the percentage of this 5A. For example, when the current reaches 1% of 5A, it can measure accurately, and achieve the standard of accuracy, such as measuring the accuracy of the meter under the ratio of 1%, 10%, 50%, 70%, 100%, etc. of 5A. As a reference, this parameter is meaningless to the user.
Q: I would like to ask the relationship between the power of the water pump motor and the flow of water
As long as the motor eats, it doesn't matter. You test it with a caliper watch. The current is not over loaded
Q: How to use the correct measuring clamp current meter
Using the graphic method of current clampClamp meter AC DC current measurementClamp meter measuring voltage clamp meter surge current measurement
Q: Emerson DC panel
The current imbalance, see the information monitoring module, 1.3A module and current, and the clamp type table card under the battery load current, see Holzer 's are not allowed, no output voltage clamp meter, Holzer scale to see how much is MV, can be converted into the hypothesis correctly, that the question in the module I guess, you have a floating voltage module, the fault code E31
Q: What is the current clamp? What are the main points on ammeter selection?
Clamp ammeters also called clamp table, Taiwan more named hook table. Clamp meter is clamped in the wire, cut off the circuit state, current detection convenient testing instrument (also known as nondestructive measurement). Analog pointer multimeter and digital multimeter is current detection circuit is cut off, and the clamp meter just caught in the electric wire sheath, current can be detected.
Q: But after 3 minutes on the machine, there is no electricity, what's the matter?
At first glance, under cooling state, adjust the temperature controller to the user, set the temperature 6 degrees lower than room temperature time temperature to 8 DEG C in 15 minutes after running, the normal air conditioning in the indoor machine hydraulic pipe should be no frosting phenomenon, if this phenomenon if there is leakage of fluorine failure. If there is a hydraulic pipe connector of indoor machine oil, which also shows that air conditioning has produced fluorine leakage phenomenon.Followed by touch, touch the air conditioning after the condenser shutter fan, if the hand temperature is not changed, and the compressor at work, which means that the fluorine has been run. Because the compressor is working, there is no heating or cooling.If you find that the compressor has been working since it started, there is no vibration of the compressor, and the sound of the compressor self shock is larger than that of the newly purchased air conditioner. This may be the abnormal sound caused by leakage of fluorine.Finally, temperature measurement. Find a thermometer, close to the air outlet, look at the thermometer indicates whether 6 to 8 DEG C lower than room temperature, as shown in the temperature lower than the indoor temperature less than 5 degrees even at room temperature and not much difference between, continues and the compressor work, it shows that air conditioning fluoride may have leaked.
Q: Automatic tripping of circuit breaker often, this is why, what to do?
Second reason is the load, cite a simple example, if the current line is 200A, and the frame current circuit breaker 100A, access motor, the normal line, but for the circuit breaker has obvious overload, it will cause the circuit breaker has been tripping. As for load tripping, the most common is that in our daily life, the current leakage caused by excessive current (such as DZ47le-32 leakage circuit breaker) tripped. Generally speaking, tripping due to load should not occur, and the parameters such as rated current of the line should be known when the model is selected. Here is also added a little knowledge: if the circuit breaker in the starting instant trip occurs, is caused by short-circuit. In the start process, tripping is caused by overload.
Q: What's the reason for the leak on the air conditioner? The pipes outside are changed, but the air conditioner is nearby
Central air-conditioning settings are also very important. Hot customers home after open air conditioning, often want to step to set the temperature at 25 DEG C, if the air conditioning installation company to set reasonable, so even if the air conditioning on a set at 25 DEG C, but after the start but will be out of the wind, a little chilly, and then to gradually cooling the air outlet. The panel temperature decreases gradually, in order to adapt to the indoor temperature is higher, and will not be a step in the air outlet panel temperature drop caused by condensation.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords