Parameters | ||||
Product Model | ES-BOX12 | ES-BOX12 PRO | ES-BOX12 PLUS | ES-BOX12 MAX |
Product Specification | 51.2V 100Ah | 51.2V 150Ah | 51.2V 200Ah | 51.2V 280Ah |
Nominal Voltage | 51.2V | 51.2V | 51.2V | 51.2V |
Nominal Capacity | 100Ah | 150Ah | 202Ah | 280Ah |
Cell Type | (LFP) | (LFP) | (LFP) | (LFP) |
Standard Charge Voltage | 58.4V(adjustable) | 58.4V(adjustable) | 58.4V(adjustable) | 58.4V(adjustable) |
Max Charge Current | 100A | 150A | 150A | 200A |
Discharge Cut-off Voltage | 40V(adjustable) | 40V(adjustable) | 40V(adjustable) | 40V(adjustable) |
Max Discharge Current | 100A | 150A | 150A | 200A |
Display | LED | |||
Parallel Function | Support 10 Units In Parallel | Support 15 units In Parallel | Support 15 Units In Parallel | Support 15Units In Parallel |
Communication interface | RS485、RS232.CAN(Optional) | |||
Cycle Life | ≥6000 Cycles (80%DOD) | |||
Charge Temperature Range | 0~65℃ | |||
Discharge Temperature Range | -20~65C | |||
Dimensions | 480*600*15OMM | 480*650*18OMM | 480*650*225MM | 480*650*225MM |
Weight | 47Kg | 80Kg | 93Kg | 130Kg |
Installation Method | Wall Mounted / Stand |
Source with confidence
√ Direct from Verified Custom Manufacturer
Order!Order!Order!
CONVENIENT AND BEAUTIFUL ENERGY STORAGE DEVICE, TO ENSURE THAT YOU CAN GET THE LIGHT AT ANY TIME AND PLACE. TO ORDER IT, QUALITY SERVICE, REASONABLE PRICE AND PERFECT AFTER-SALES.
FAQ:
Q1. Can I have a sample order?
A. Yes, welcome sample order to test and check quality.
Q2. How about after-sales service?
A. We will provide you with a 3 years warranty. If there are any problems, please let us know and we will provide you with a positive solution.
Q3. What about the lead time?
A. Sample 5-10 days, mass production time 3-5 weeks depending on order quantity.
Q4. Do you have any MOQ limit?
A. Yes, but low MOQ, 10pcs order is available.
Q5. How do you ship the goods and how long does it take to arrive?
A. We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Bigger order shipped by air or by sea.
Q6. How to proceed with an order?
A. 1st, please let us know your requirements or application. 2nd, We offer our quotation. 3rd, customer confirms the samples and make a deposit for formal order. 4th, We produce your order.
Q7. Can you print my logo on the product?
A. Yes. Please supply us the artwork before mass production.
- Q: What are the technical parameters of the battery?
- Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
- Q: How to deal with waste batteries?
- The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
- Q: What battery does the van use?
- The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
- Q: What are the advantages of maintenance-free batteries?
- Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
- Q: How should the battery be well maintained?
- Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
- Q: 80ah how much battery storage capacity?
- Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
- Q: The role of the battery?
- Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
- Q: What kind of battery is divided into?
- Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
- Q: Battery 200ah / 104 what does that mean?
- This should be refers to 2V200AH battery 104, power with the 220V.
- Q: Lead-acid battery how to maintain?
- After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.
Send your message to us
lithium ion battery 51.2V 200Ah LiFePO4 battery Server Rack LiFePO4 Battery NCQ
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords