Lead Acid Battery TT Series Battery TT12V42

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
500000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Range  summary:

NARADA TT series valve regulated lead acid batteries  are designed with AGM(Absorbent Glass Mat) technology,    high performance plates and electrolyte to gain  extra power output for common power backup system applications widely used in the field of communication  power, military and broadcast and television system.
                               

The TT series batteries are ensured the quality  with NARADA's QA system according to the ISO9001 and ISO14001 standard.

Lead Acid Battery TT Series Battery  TT12V42

Technical feature:

 

  1. Reliable Seal Technology

  2. Special Patented grid alloy

  3. Excellent high rate discharge performance

  4. Low internal resistance AGM separator

  5. Flame retardant ABS material container and cover compliant with UL94 V-0

  6. Self-regulating pressure relief valve

  7. The design float life is 12 years at 68oF(20oC)

 

Type:

  TT12V42

Voltage:

  12V

Nominal Capacity:

  52Ah(C10)  52Ah(10 hours rate:)

Length:

  220mm

Width:

  121mm

Height:

  243mm

Height  with termial:

  246mm

Weight:

  17.8Kg

Compliant standards :

  • IEC60896-21/22

  • Eurobatt guide

  • UL

  • Manufactured under system ISO9001(TUV)

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main application:

  • Cable Television

  • Communication Equipment

  • Security System

  • UPS

  • Control Equipment

  • Medical Equipment

  • Emergency Power System

Products characteristics:

  • Recommended float charge voltage for 12V  battery:

  • 2.25Vpc at 77oF(25oC)

  • Self discharge rate: < 2% per month at   25oC

  • Shelf life: six months at 68oF(20oC)

  • Valve regulated system, no water addition  needed.

FAQ

Is there a maximum temperature for charging lead acid batteries?

When charging lead acid batteries, the temperature should not exceed 120ĄăF. At this point the battery should be taken off charge and allowed to cool before resuming the charge process.

Are lead acid batteries recyclable?

Lead acid batteries are 100% recyclable. Lead is the most recycled metal in the world today. The plastic containers and covers of old batteries are neutralized, reground and used in the manufacture of new battery cases. The electrolyte can be processed for recycled waste water uses. In some cases, the electrolyte is cleaned and reprocessed and sold as battery grade electrolyte. In other instances, the sulfate content is removed as Ammonia Sulfate and used in fertilizers. The separators are often used as a fuel source for the recycling process.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .


 

Q: What is the difference between a maintenance-free battery and a conventional battery?
As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
Q: What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q: How to deal with waste batteries?
Laboratory recycling method: ordinary dry battery is cylindrical, the outer cylinder made of zinc, the zinc cylinder is the battery negative; tube central carbon rod for the positive; tube for the manganese dioxide, ammonium chloride and chlorination Zinc.
Q: Maintenance-free battery how to detect it?
Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
Q: What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q: What is the meaning of the battery above 12v65Ah?
12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
Q: How should the battery be well maintained?
Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
Q: 80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q: What kind of battery is divided into?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.
Q: Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.