• lead-acid battery Toyo AGM VRLA deep cycle 12V 90AH System 1
  • lead-acid battery Toyo AGM VRLA deep cycle 12V 90AH System 2
lead-acid battery Toyo AGM VRLA deep cycle 12V 90AH

lead-acid battery Toyo AGM VRLA deep cycle 12V 90AH

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Place of Origin: Jiangsu, China (Mainland)

  • Model Number: LCPA90-12

  • Usage: UPS

  • Voltage: 12v

  • Sealed Type: Sealed

  • Maintenance Type: Free

  • Size: 406*174*238(mm)

  • Weight: 30±0.5KG

  • Nominal Capacity: 90AH

  • Model: 12V90AH

  • size: 406*174*238(mm)

  • Nominal Capacity: 90AH

  • 100%DOD: 572times

  • 50%DOD: 1485times

  • 30%DOD: 2406times

  • self-discharge: <3%/month

  • packing: carton and plywood made in china

  • use: 12v battery

  • mode: 12v battery

Packaging & Delivery

Packaging Details:the packing of battery carton and plywood packing or recording to our clients' demand.
Delivery Detail:15-20 weekdays after receiving the deposit

Specifications

Toyo AGM VRLA deep cycle 12V 90AH lead-acid battery 
1)Germany material 
2)ce,ul,msds ,cgc,tlc 
3)export experience 15 years 

 

Battery Features:

1.The whole series are medium size sealed battery.

2.Long service life; designed life is six years.

3.Positive grid is thickened type.

4.Anode and cathode wrapping technology shall be adopted.

5.CW-M-101 sealant shall be adopted and it has the characteristics of good air-tightness, anti-vibration and corrosion resistance.

6.Calcium base hexabasic alloy particularly owned by the enterprise and scientific direction shall be adopted.

7.Proprietary formula of electrolytic solution shall guarantee excellent charge acceptance.

8.Japanese original additives shall guarantee excellent recovery capacity of battery after discharge.

5.

Q: How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q: What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q: What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q: What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q: Maintenance-free battery how to detect it?
Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
Q: What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q: How should the battery be well maintained?
Battery Pile The battery pile head is part of the battery connected to the vehicle. If the corrosion or poor connection occurs, the battery will work poorly. The owner can check whether there is a white powder near the pile head, which is the sign of the pile head corrosion. If the white powder is more, you can use boiling water to burn it off, and then its anti-corrosion treatment, in the pile head smear some grease or preservatives can, but should not be too much to apply, so as not to affect the use.
Q: What kind of battery is divided into?
Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
Q: Battery 200ah / 104 what does that mean?
2V battery capacity (from 200AH-3000AH have) long design, good stability, the price is also expensive; 12V battery capacity is generally the largest 250AH, design life as 2V, price economy, high current discharge better.
Q: How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.

Send your message to us