lead acid battery 2 v 600 ah for solar system
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 450000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: Jiangsu, China (Mainland)
Brand Name: Oliter lead acid battery
Model Number: GFM600-2
Usage: UPS
Voltage: 2v
Sealed Type: Sealed
Maintenance Type: Free
Size: 301*175*366(mm)
Weight: 34kg
Nominal Capacity: 600AH
type: lead acid battery
self-discharge: <3%/month
packing: cartoon
HS Code: 8507200000
product capacity: 150000pcs/day
Factory: 400000 square meter
export markets: America, Africa,Mid-east,Asia,South-America,Europe
Certificate:
ISO9001
ISO14001
ISO18001
CE
CGC
TLC
Standards:
GB/T 19638.2-2005
YD/T799-2002
JISC8704-2:1999
IEC60896-2,2000
Specification:
Rated Voltage | 2V |
Capacity(10hr,1.80V/Cell,25℃) | 600ah |
Weight | 32kg±0.5 |
Max.Discharge Current | 30I10A (3min) |
Self-Discharge(25℃) | <3%/month |
Using Temperature | Discharge: -45℃~50℃ Charge: -20℃~45℃ Storage: -30℃~40℃ |
Recommended Using Temperature | 15℃~30℃ |
Max.Charge Current | ≤0.25C10 |
Charge Voltage (25℃) | Float Charge: 2.25V-2.3V
Average Charge: 2.4V-2.45V |
Cover Material | ABS Engineering Plastic |
Charge Mode(25℃) | Float Charge:2.275±0.025V/Cell Temperature Compensation Coefficient :±3 mV/Cell ℃ Cycle Charge:2.45±0.05V/Cell Temperature Compensation Coefficient: ±5 mV/Cell ℃ |
Capacity Affected by Temperature | 105 % @ 40℃ 85 % @ 0℃ 60 % @ -20℃ |
Cycle life |
100%DOD 520times 50%DOD 1350 times 30%DOD 2188times
|
- Q: How to repair the battery?
- Connect the positive and negative output of the repair instrument to the positive and negative pole of the battery, open the repair instrument, repair the battery. The first repair time should be no less than 48 hours.
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
- Q: How to determine the battery is good or bad?
- If less than 9V but the pointer is in a certain value does not move that the battery is in a state of loss, need to add charge.
- Q: What are the hazards of battery over discharge?
- The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
- Q: What battery does the van use?
- General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
- Q: What are the advantages of maintenance-free batteries?
- Maintenance-free battery using lead-calcium alloy grille, the amount of water generated when charging less water evaporation is low, with the shell with a sealed structure, the release of sulfuric acid gas is also very little, so with the above advantages.
- Q: What is the meaning of the battery above 12v65Ah?
- 12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
- Q: 80ah how much battery storage capacity?
- The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
- Q: The role of the battery?
- It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
- Q: How does the battery increase the voltage?
- You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
Send your message to us
lead acid battery 2 v 600 ah for solar system
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 450000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords