• Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free System 1
  • Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free System 2
  • Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free System 3
  • Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free System 4
Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free

Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 set
Supply Capability:
1000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Description and specifications of Lead Acid AGM Battery 12V 150AH Rechargeable Storage Maintenance free
Application: Home Appliances, Consumer Electronics, Electric Power Systems, Solar Energy Storage Systems, Uninterruptible Power Supplies
Battery Type: deep cycle sealed AGM
Model Number: 12V150AH AGM
Certification: CE, IEC, ISO
Battery Size: 485*170*240/240
Place of Origin: Jiangsu, China
Weight: 42KG
Warranty: 3years

2. Main features of Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free
- Maintenance-free, absorbent glass pad technology
- Wide ambient temperature range
- Low self-discharge
- Design long service life
- Good discharge performance
- Environmentally friendly

3. Application field of Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free

Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free
- Solar and wind energy storage systems
- EPS and UPS backup batteries
- Signaling system, emergency lighting system and security system
- Telecommunications equipment
- Power supply for portable devices or tools


4. Package details
Sea transport package: carton, pallet

Lead Acid AGM Battery 12V150AH Rechargeable Storage Maintenance free 

Q: How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q: How is the capacity of the battery defined?
The capacity of the battery unit is AH (safety) is the product of current and time.
Q: How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q: What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q: 80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q: The role of the battery?
Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.
Q: How does the battery increase the voltage?
The so-called battery is the storage of chemical energy, if necessary, the release of electrical energy of an electrical chemical equipment.
Q: What is a maintenanceable battery?
It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Q: Battery 200ah / 104 what does that mean?
2V battery capacity (from 200AH-3000AH have) long design, good stability, the price is also expensive; 12V battery capacity is generally the largest 250AH, design life as 2V, price economy, high current discharge better.
Q: Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.