intelligent high frequency radar level transmitter/gauge
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.
Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.
Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.
Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel.
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.
Input:
the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.
When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)
Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.
4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire)
CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.
- Q: What are the commonly used rotor types for power tools?
- Electric tools commonly used bearing type: 606, 607, 608, 626, 627, 628, 629, 6000, 6001, 6003, 6004, 6200, 6201, 6202, 6203, 6303, 61907, 688 commonly used carbon brush models: 50#, 408#, 43#, 44#, 303#, 21#, 6M etc.
- Q: Which is good between pneumatic tools and power tools?
- The use of pneumatic tools:1., the air is easy to obtain, and the work pressure is low, the used air can be discharged locally, without the need to recover the pipeline2. gas viscosity is small, flow resistance loss is small, easy to central gas supply and long-distance transportation3. pneumatic actuator, high movement speed4. the pneumatic system has a strong adaptability to the environment. It can work reliably in a wide temperature range, humid and dusty environment, with a slight leakage, no pollution to the environment, no fire and explosion hazards, and safe use5., simple structure, convenient maintenance and low cost6. long life of pneumatic components7. pneumatic actuators of the hydraulic output than small, fast, strong adaptability, can exercise in the flammable, explosive, heavy, damp, the impact of the harsh environment, no environmental pollution, long service life, simple structure, easy maintenance, low price.
- Q: What kind of power tools are hand drills? 1, 2 or 3?
- I class: in the prevention of electric shock protection, in addition to relying on basic insulation, but also the need for zero protection.Class II: the tool itself has double insulation or insulation without the need to protect the ground.Class III: Powered by a secure, ultra low voltage power supply, no voltage higher than the safety supply voltage is generated within the tool.The above is the classification of insulation categories.
- Q: What safety problems should we pay attention to when using electric drills or hand-held power tools?
- All conducting parts must be well insulated,
- Q: How are the I, II, and III classes of power tools classified?
- The popular point is that:The 1 type of tool is metal housing with ground wire.The 2 type of tool is the insulated housing.The 3 type is low voltageOfficial point of explanation can be searched for power tool category ~!
- Q: Power tools are power tools?
- Divided into electric, pneumatic, gasoline tools, currently on the market these 3 main types. I've been a tool for over 10 years
- Q: Why hand grinding sand turbine, electric drill, impact drill and other power tools plug is two, plug is not three plug
- Each of these devices has a "back" logo indicating double insulation protection, and the double insulated layer forms insulation protection between the outer shell and the inner part of the tool, thereby preventing the occurrence of electric shock. So no three plug in,
- Q: What's the difference between a flashlight and an electric screwdriver?
- Equipped with torque regulation and restriction mechanism, electric tool for screwing and unscrewing screws, the electric tool, mainly used for assembly line. Is one of the necessary tools for most manufacturing enterprises.
- Q: What material does the power tool housing fit?
- Power tools are mainly divided into metal cutting, power tools, grinding power tools, assembly of power tools and railway power tools. Common electric tools have electricityElectric drill, grinder, electric wrench and electric screwdriver and hammer, impact drill, concrete vibrator, planer.
- Q: What devices must be available for all hand held electric tools?
- Anti leakage, splash prevention, anti movement, anti overheating
Send your message to us
intelligent high frequency radar level transmitter/gauge
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords