HVAC Ventilation Ducting Flexible Air Hose Pipe
- Loading Port:
- Shekou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
HVAC Ventilation Ducting Flexible Air Hose Pipe
1.Structure of HVAC Ventilation Ducting Flexible Air Hose Pipe:
Flexible air ducts are typically made of flexible plastic over a metal wire coil to shape a tube. And they have a variety of configurations. Flexible ducts are very convenient for attaching air outlets to the rigid ductwork. It is commonly attached with long zip ties or metal band claps. Besides, flexible ducts can tolerate moderate negative pressures.
2.Main Features of HVAC Ventilation Ducting Flexible Air Hose Pipe:
-Applied in air conditioning/ventilation systems
-Tear and puncture resistant
-Corrosion resistant
-High flexibility
-Convenient installation
-No toxic gas emission
3. HVAC Ventilation Ducting Flexible Air Hose Pipe Images
4. HVAC Ventilation Ducting Flexible Air Hose Pipe Specification
Insulated Flexible Duct
Structure: 1 layer of Aluminum Foil+1 layer PET film+insulated glass wool
Outer jacket: 1 layer of Aluminum Foil
Glass Wool Density: 16kg/m3; Thickness: 25mm
Insulated Acoustic Flexible Duct
Structure: 1 layer of Aluminum Foil +1 layer PET film+ insulated glass wool
Outer jacket: 1 layer of Aluminum Foil + 1 layer of PET film
Glass Wool Density: 32kg/m3; Thickness: 25mm
Specification
Type 1
Material | Aluminum foil |
Structure | Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. |
Application | Suitable for medium-low air speed |
Technical Parameter
Size | 4”-16” |
Standard Length | 10m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
Type 2
Material | Aluminum foil 25mm thickness ,16kg/m3 glass wool. |
Structure | Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. Insulating layer is covered by 25mm thickness ,16kg/m3 glass wool. Outside layer: Reinforced aluminum foil; Inside layer: Glass fiber mesh |
Application | Suitable for medium-low air speed and low temperature difference. |
Technical Parameter
Size | 4”-5”, 6”-12”, 14”-16” |
Standard Length | 7m, 10m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
Type 3
Material | ·Aluminum foil · 25mm thickness ,24kg/m3 glass wool. |
Structure | · Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. · Insulating layer is covered by 25mm thickness ,24kg/m3 glass wool. · Outside layer: Reinforced aluminum foil; Inside layer: Glass fiber mesh |
Application | Suitable for medium-low air speed and large temperature difference. |
Technical Parameter
Size | 6”-12” |
Standard Length | 7m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
1.How long for the delivery time?
Delivery time: 10-30 days, it depends on the ordered quantity.
2.What’s the usage?
Practicality: suitable for the densely-populated area(such as school, supermarket, office, stadium, theater, factory.),high requirement of the environment area, such as hospital, laboratory, howff, bus, train, broadcasting studio. main usage: 1) Cold, hot water supply facilities for public buildings 2) Food, chemical, electronic industrial pipeline networks such as pipeline networks for transporting all kinds of corrosive liquid 3) Drinking water production system pipeline networks such as pure water and mineral water 4) Air conditioning facility pipeline 5) Compressed gas pipeline networks for industry 6) Pipeline network for swimming pool 7) Pipeline network for solar energy facility 8) Agriculture and garden production Additional information
③How you control the quality?
During the production of fiberglass insulation, material is sampled at a number of locations in the process to maintain quality.
- Q: Such as the problem, and now air-conditioning technology is mature, the market a lot of air conditioning are cold and warm, and I would like to be able to put my home that the end of the century loaded Mitsubishi air conditioning (split single cold) into a cold Before the conversion of ordinary TV to the remote control, that air conditioning can be modified? How much does it cost? Where is this technology? More
- So good, then you recommend more. Give an address. You are not layman, too modest.
- Q: Air conditioning ventilation when the sound is a big reason
- Buried plastic pipe under external load, the diameter of the vertical diameter deformation rate should be less than the allowable diameter of the pipe deformation rate The diameter of the allowable diameter of the pipe shall not be greater than 5% The diameter deformation rate of the pipe and the allowable diameter deformation rate are calculated as follows: ε ΔD / D0 × 100% [ε] ε0 / K where: εΔD pipe in the combined load (Mm) [ε] Permissible diameter Deformation rate ε0 Elastic diameter Deformation rate (%) of pipe, by the flattening of the diameter of the pipe diameter (mm) The test determines the K safety factor, generally desirable 15
- Q: US direct mail dysonhp01 Dyson air purification cooling machine triple in the country to warranty it
- Embedded stove, such as the use of rubber tube connection, then the rubber tube in the platen, often subject to heat radiation easily aging; and aging, falling more difficult to find, so many local poisoning and other vicious accidents
- Q: Gree air conditioning 50 heating and cooling mechanism heat when the host cooling network is how the matter
- Not the ,,, mobile air conditioning inside the compressor, the winter heating also need the compressor, but also a ventilation pipe, charged heating Well?
- Q: Do 3cm thick wall insulation how much kilogram of slurry and how many kilograms of polystyrene particles
- From the outside: ① rigid waterproof casing is only composed of steel casing and wing ring, simple structure; ② flexible waterproof casing mainly by: flange casing, seals, flange pressure plate, wing ring, bolts, nuts Composition, complex structure From the waterproof performance up to choose: ① rigid waterproof casing is outside the wing (ring made of steel ring on the steel pipe), installed in the wall (mostly concrete wall), for the general pipe wall, ; ② flexible waterproof casing in addition to the external wing ring, the internal file ring and the like, the flange wire, there are sets of sales, but also their own processing, for the need for shock absorption pipeline, such as and pump connected When the pipe is through the wall In other words, if the wall on both sides of the waterproof performance, it is necessary to use flexible waterproof casing; if only to consider the pipe through the wall, without considering the wall, the wall on both sides of the waterproof performance and displacement of the pipeline deformation You can use rigid waterproof casing
- Q: I added the space 18 degrees opened for 5 hours or not cold, we all know how is it? More
- The general level of more than 12 layers when you need to use.
- Q: What is the whole heat exchange fresh air ventilator?
- (GJG130 - Fan Jutang Duanjie Daojie Juejiao 2001) will be replaced by (GJG130-2011) is expected to begin the implementation of the construction of this year, the construction of fastener steel scaffolding safety technical specifications (GJG130), the construction of fastening steel pipe scaffolding safety technical specifications (GJG130- -2011)
- Q: External wall insulation method of operation There are several combinations of materials
- 30-150 per square meter has, mainly to see the material, thickness and so on
- Q: Ventilation is very good, why still have to install fresh air system
- Also known as foam board, EPS board, is containing volatile liquid blowing agent of the polystyrene beads can be preheated by heating, heated in the mold and the formation of white objects
- Q: HVAC Heating: What are the main components of the air distribution system?
- Geothermal construction, the heating pipe spacing can not be less than 100mm, the construction can not be achieved, big brother!
Send your message to us
HVAC Ventilation Ducting Flexible Air Hose Pipe
- Loading Port:
- Shekou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords