• Hong Rui Long distance multiplexer communication fiber optic cable System 1
  • Hong Rui Long distance multiplexer communication fiber optic cable System 2
Hong Rui Long distance multiplexer communication fiber optic cable

Hong Rui Long distance multiplexer communication fiber optic cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
10000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:


Brand Name:


Model Number:

HRDV-16VZ1DF-2

Type:

communication fiber optic cable

Certificates:

CE/FCC/RoHs

Audio Channel:

Forward/ Reverse Audio

Fiber Mode:

single mode or multi mode

Video Interface:

BNC

Video input/output impedance:

75ohm(unbalanced)

Working Temperature:

-30 C ~ +75 C

Video Channel:

16 channel

Video Digital Bit Width:

8/10 bit

Input Rating Voltage:

AC220V/50Hz





Packaging & Delivery

Packaging Detail:Carton lined with pearl cotton
Delivery Detail:3-7 working days after payment

Specifications

communication fiber optic cable 
1. Manufacturer, factory price 
2. In stock, fast shipping 
3. CE/FCC/RoHS 
4. OEM service

 

long distance multiplexer communication fiber optic cable features

 

1. 8-bit or 10-bit digitally encoded and non-compression video transmission

2. Directly compatible with NTSC, PAL and SECAM CCTV camera systems and support RS-232, RS-422

    and RS-482 data protocols

3. Power supply and other parameter state indication, which can monitor the operation condition of system

4. Support no-damage regenerative trunk of video

5. Constant input optical power, and large dynamic range, no electrical or optical adjustments required

6. Special ASIC design

7. Industry-grade of operating temperature from 10 to 75, which is applied to the different working environment

8. Hot-swap function

9. Stand-alone type or card-type installed in 19" 2U or 4U rack-mount chassis

10. Optical interface: FC, ST, SC(optional)

11. Abundant signal interface, such as video, data, audio, telephone, Ethernet, binary input/ output and talkback

 

* Application

 

1. City traffic monitoring system 

2. Police and safe city monitoring system 

3. High way security protection and toll station system 

4. Building and campus monitoring system 

5. Industrial monitoring(airport, chemical plant, steel, oil, railway, irrigation works, mine and so on) 

6. Military monitoring(storage, frontier defense, guard, national defense and so on) 

7. Electronic power oil field, TV station program broadcasting system 

8. Gymnasium (live video and audio transmission)

 

* Order Information

 

Part No

Description of product

Transmission Distance

HRDV-16VZ-2

Multimode and 16 CH video

0-2KM

HRDV-16VZ-20/40/60/80

Single mode and 416 CH video

0-80KM

HRDV-16VZ1DF-2

Multimode and 16 CH video + 1 CH reverse data    

0-2KM

HRDV-16VZ1DF-20/40/60/80

Single mode and 16 CH video + 1 CH reverse data 

0-80KM

 

Special Specification: Video+Data+Audio+Ethernet+Phone+Alarm, Long transmission distance.

Our Multi-function products have competitive price! Can be customized according to your personal requirements !

 

* Accessories in the package

 

User Manual

maintenance card

Qualified Certification

Power Adapter

Device

1 copy

1 copy

1 copy

1 pcs

 

1 pair

 

 

* Video Feature

 

Video Interface: BNC
Video input/output impedance: 75Ω (unbalanced)
Video input/output Voltage: 1VP - P (peak value),Max 1.2Vpp
Video Bandwidth: 10MHz
Video sampling: 15MHz high speed sampling
Video digit bit width: 10 bit
Differential gain: ( 10%-90%APL) DG <1%( Typical value)
Differential phase: ( 10%-90%APL) DP <0.8°( Typical value)
Video SNR: S/N ≥ 70dB (Maximum optical link path loss)

 

* Audio Features

 

Audio interface: Forward Direction, Reverse Direction or Bi-directional Audio
Interface terminal: standard industrial connecting terminals or lotus terminals
Audio input/output electric level typical: 0dBm
Audio input/output impedance: 600Ω (balanced/unbalanced)
Audio input/output amplitude: 2VP-P(peak value)
Audio bandwidth: 20Hz~20kHz
Sample rate: 58.6K
Nonlinear distortion coefficient: ≤ 1 %
Audio SNR: S/N≥85db

 

* Data Features


Interface:standard industrial connecting terminals
Controlling Equipments: PTZ decoder, Keyboard ,data interface of Matrix, High speed dome camera, industrial equipments
Interface Signals: RS-485(2 lines),RS232,RS422 and so on


Q:What is the difference between wires and cables?
The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
Q:Wire and cable fire resistance to meet what standards, which can provide about, thank you!
Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!
Q:Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q:This cable or accessory has not been certified and may not be able to work with this iphone reliably
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
If you need an unqualified wire, you can contact this part
Q:If you want to sell wire and cable, then what to do in advance to detect? The The The The The
If you use the color component output, you have to have the color difference component interface. With the color line facing the same color on the line. AV line of the yellow plug is the video, red and white is the audio delay Han silhouette cellar jealous of the tea, according to the same color received TV
Q:Why does the bird stand on the wire without anything, but if people touch it,
Please provide air-conditioned three-leg socket photo, because you said "open inside is 2.5 square line ~ is a separate line ~" is not very understanding.
Q:Wire and cable model ZD what does it mean
Put the water clean, with a table to measure the insulation resistance between the lines, as long as no less than 1.5-2 can.
Q:Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
There are [the top of the machine can be broken off the ball can be hit by Jiu turtle snow box video output cable and DVD video output line] into a junction box, and then through the sub-box toggle switch to select the 'set-top box' or 'DVD'; This junction box outputs a wire connection device or is connected to a TV.
Q:Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords