• High Pressure Steel Wire Spiral Rubber Hose System 1
  • High Pressure Steel Wire Spiral Rubber Hose System 2
  • High Pressure Steel Wire Spiral Rubber Hose System 3
High Pressure Steel Wire Spiral Rubber Hose

High Pressure Steel Wire Spiral Rubber Hose

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Basic Info.

 Material:Nitrile Rubber

Capability:Rubber Oil Hose

Color:Black

Delivery:20days

Warranty:1year

Working Tempereture:-30~130

Export Markets:Global

 

Additional Info.

Packing:Box

Standard:CE, API, SGS

Origin:China

HS Code:40092200

 

Product Description

Specifications
API 16C Choke and kill hose high pressure 
1 according to API 16c standard 
2 Competitive pirce and fast delivery 
3 Max length:
API 16C Choke and Kill hose high pressure
The Choke and kill hose meets  API 16C spec standard,  it is designed for modern drilling methods, including horizontal drilling, dynamic pressures, high fluid temperatures, complex fluids, high pressure drilling, high flow rates and large hose sizes.
SURVIVAL TEMPERATURE: Tube: 350°F (177°C) for 1 hour per API Spec 16C 10.5.2.
TEMPERATURE RANGE: -4°F to +212°F (-20°C to +100°C).
TUBE: Synthetic polymer. Black. Resists abrasion, corrosion, oil, drilling, muds, methane, and H2S.
REINFORCEMENT: Multiple layers of "close-wound," high tensile plated steel cables, with multiple layers of textile reinforcement under the cover.
COVER: Modified Nitrile. Black, the cover is resistant to abrasion, corrosion, cutting, gouging, oil, and weather. Outer armor of 316 Stainless Steel.
DESIGN FACTOR: 2.25:1
COUPLINGS: Crimped. Couplings will be supplied with your choice of end fittings. (A full range of fitting options are available, including hammer unions, hubs, and flanges.) Per API, the end fitting pressure rating must be equivalent to the pressure rating of the flexible hose. Carbon steel material.
Note: Field welding of fittings to couplings is not recommended.
OPTIONAL: Accessories such as safety clamps, hose lift eyes, and collar clamps. Coupling material traceability

 



 


CHOKE AND KILL HOSE

Part Number

Hose I.D 
     (in)

Hose O.D. 
      (in)

Rated W.P.
     (psi)

Test Pressure 
          (psi)

Min. Bend Radius

Wt. Per Foot 
        (lbs)

1

2.0

4.68

10000

15000

48

22.4

2

2.50

5.34

10000

15000

              52

27.4

3

3.00

5.84

10000

15000

56

28.8



 



Tube:

Black, oil and abrasion resistant HNBR for H2S sevice.

Reinforcement:

Multiple plies of bias laid textile cord for extra strength and flexibility. 
Spirally wound, high tensile, multiple strand cables to provide unsurpassed 
ruggedness and reliability to withstand sudden high pressure.

Cover:

Special flame resistant Neoprene  with optional stainless steel armor.

Temperature:

-40 to 212° F.

Fittings:

Integral connection flanged or hubbed.

Branding:

 Choke & Kill Hose. 

 

High Pressure Steel Wire Spiral Rubber Hose

High Pressure Steel Wire Spiral Rubber Hose

 

FAQ

Acceptable payment term and way?             

 T/T,L/C, T/T + L/C,

Acceptable price term?           

 FOB  CNF  CIF  DDU  CPT          
Do you accept OA payment terms?    

Yes, sure, but it normally depending on the order value    
Do you have QC team?      

Yeah, sure, our QC team is very important, they will keep the quality control for our products.
What is the validity of your quotation?    

Normally 7 days.
What is your advantage?
24 hour quick response /Customer oriented/ Credit foremost/ Top quality Excellent 

 

 

 

 

 

 

Q: What glue can glue rubber tube?
1: clean: high temperature, quick drying glue, use dry cotton cloth or sand paper, then dust, oil, rust, etc., and then use the treatment agent or cleaning agent to clean, then clean the surface.2, sizing: flexibility speedglue unscrew the front cover, can be used as a glue bottle with cotton cloth to wipe clean and quick drying glue, can be set using needles or PE dropper, to control the flow of glue, ensure the bonding effect.
Q: High pressure hose K type joints KJR32 and KJR31.5D what is the difference between ah, please give us a answer,
K type joint has the distinction between national standard and German standard. In general, 32 of the tubes are 1 1/4 inches, and the K type mine connections are also 1 1/4, but there are two methods of KJR32 and KJR31.5D. But KJR31.5D, D means that the inner diameter is 1 1/4 inches.
Q: How far is the gas cooker from the gas riser in the kitchen?
The safety distance between stoves and gas pipelines is at least greater than 50 cm. This answer is the standard answer.
Q: The engine cylinder head cover behind the drop rubber tube what reason (Xichai 490 engine) (note the valve chamber cover tube)
Air conditioning water pipe, the specific recommendations on the map below, I hope my answer can help you.
Q: How can we prevent the aging of rubber tubes?
The second is the design of the structure of the rubber products (especially damping products), has a great relationship between aging and fatigue, should avoid stress concentration! If the product is good has been produced to prevent aging, more trouble! Can be sprayed on the rubber surface, spraying insulation polymer.
Q: Will the electric water heater be well connected with metal hose or hose?
The electric water heater, now in the industry are required to use PPR on the inlet and outlet pipe welding, a long service life, can effectively control the water heater outlet Water Leakage; on the other hand, can avoid the water heater power switch for two grounding and frequent take-off effectively. Therefore, the metal pipe connection does not meet the safety and installation specifications
Q: Is the rubber pipe joint installed in the middle of the pipe and pump for shock absorption?
Control the noise produced by parts of machinery, equipment, and equipment. The pump foundation of the new pump house should adopt heavy weight to prevent vibration from producing noise. Vibration isolation should be set up with rubber vibration isolating pads to reduce vibration noise. Each pump unit shall be provided with a foundation to prevent resonance. Use "soft" connection as far as possible in the suction pipe and pressure pipe of the pump. Periodic maintenance problems, such as packing leakage, equipment parts loose, serious wear and tear of equipment parts, mechanical vibration and so on, should be repaired in time, thereby reducing noise.
Q: Why should the water stop strip be joined by heat instead of superposition?
Lap joint of rubber water stop belt is lap joint, this method is not allowed in engineering, glue glue and do not use overlay. In the case of splicing, it is equivalent to not doing any treatment at the joint. In the process of pouring, the sealing strip is prone to roll and twist.
Q: How to make sure the rubber hose will not be worn off?
The sole judgment is as follows at the end of the rubber bottom or tendon tendon end methods: look at the color, color is usually translucent, while the rubber bottom is not.
Q: What's the difference between hose and hose for compressed air?
In use, it is usually marked with color. For example, the intake is made of blue, and the exhaust is made red, but it is not necessary.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords