Handheld precious metals analyzer
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
S1 TITAN handheld precious metal detector using a Bruker patented SharpBeam ™ has optimized detector, S1 TITAN running at low power, thus greatly increasing the battery life. S1 TITAN wide range of elements make it particularly suitable for the analysis of precious metals. In addition to gold, silver, nickel, copper, S1 TITAN also can measure all possible alloying elements from Ti-Bi. Use S1 TITAN uses a high-contrast LCD touch screen, and optional integrated digital camera & small point, to accurately determine the correct target sample region is very easy. In addition, S1 TITAN also matching the latest technology to protect the anti-tie detector detectors, without affecting the accuracy of the instrument itself, the situation greatly reduces the life of the equipment maintenance, giving the user with considerable economic effects.
General handheld spectrometer detector window was punctured in contact with sharp metal materials (such as wood shavings and filaments), etc., very easy, and therefore had to be repaired or replaced, and Brooke anti-tie detector completely avoid this problem the emergence of minimizing the probability of being punctured detector window, which is a new high-tech modern technology, not only safe and reliable, to avoid long waits for repairs, but also to the user to save a large part of the funds. Anti-bar detector can withstand sharp objects up to 50 Newtons pressure.
Handheld precious metal detector main features
SharpBeam® configuration
Very intuitive user interface
Grade library: Zig Ziglar, alloy
HD CCD color camera and a small point measurement
50 kV tube
Available options
Anti-bar detector ShieldTM
Integrated camera
Stand
Handheld precious metal detector design programs take full account of the small sample, irregular shapes and surfaces - even smaller than the sample case of the beam diameter, making the measurement more humane, more convenient. S1 TITAN handheld precious metal detector when measuring large samples can be placed directly on the optional desktop or desktop stand. For samples of the same ring or chain easily detect. Such as cups, plates and the like. S1 TITAN features a remote control system, while providing custom reports, including the test sample photos.
S1 TITAN can quickly identify common alloy. Results are reported directly to the carat displayed, while the other contains all the elements detected, and displayed in%. When the device detects suspicious ingredients or jewelry carat value is lower than the standard value of the system will issue a warning.
Precious metals testing .jpg
Focuses on the detection of precious metals analyzer jewelry, jewelry, gold and other jewelry in Au, Ag, Cd, Co, Cr, Cu, Fe, In, Ir, Mn, Ni, Pb, Pd, Pt, Rh, Ru, Sb, Sn, Ti, Zn and other elements, Bruker handheld precious metals analyzer provides an accurate and reliable solution for analysis of gold and other precious metals sample tool. You can easily measure the shape and size of the instrument jewelry samples. S1 TITAN precious metals analyzer is simple to operate, completely non-destructive, is the ideal tool for the analysis of gold and other precious metals.
From necklaces to earrings and wedding rings
Decorated with gold everywhere, is the most common alloy jewelry. Only in 2007, worldwide there 2425 tons of gold alloy jewelry production, with a total value of approximately $ 54.2 billion. Gold reached a record price, therefore, to know the exact gold content is more important than ever. Or buy, or sell, or recycling, it is important to have a reliable analytical methods to ensure that the gold content.
Within seconds, Brooke S1 handheld XRF analyzer can identify with great precision jewelry, gold coins, the exact content of other valuable products in gold. Bruker S1 handheld XRF tool industry can be described as jewelry, gold business, cash pawn shop, coin collectors and gold-waste recycling an ideal tool.
Bruker S1 handheld XRF analyzer provides a fast, non-destructive testing is not only entirely of gold, silver, platinum, palladium and other precious metals. In addition to the precious metal content, Bruker S1 can be accurately determined alloying elements and other trace elements such as the risk of heavy metal concentrations of lead.
Analysis gold watch
Standard noble metal that can be analyzed include: Au, Ag, Cd, Co, Cr, Cu, Fe, In, Ir, Mn, Ni, Pb, Pd, Pt, Rh, Ru, Sb, Sn, Ti, Zn
Namely: gold, silver, cadmium, cobalt, chromium, copper, iron, manganese, nickel, IR ,, lead, palladium, platinum, ruthenium, rhodium, antimony, tin, titanium, zinc
Because the gold content of the alloy units of measure carat, 24-karat gold is pure gold. Expressed as a percentage and carat weight easily between
= 4.1666% 1 karat gold. Gold and other reports of alloying elements gives Brooke S1 may be a percentage, it can be carats.
- Q: I have instrument to need to make calibration, how to choose measuring instrument calibration service?
- Each place has its own quality inspection bureau. You send your own equipment and say the parameters to be calibrated, such as strength, temperature, time, etc. they will give you a calibration.
- Q: Which is better, sic-100 multi component gas analyzer and gas chromatograph?
- Installation environmentGYE99 chromatographic analyzer in temperature and relative humidity were 5 ~ 35 DEG C and 0 to 85% range. But it is best to use it in a comfortable environment (suitable for constant temperature and humidity). In this way, the instrument can achieve the best performance, and the service life of the instrument is the longest. If the instrument is exposed to corrosive substances (whether gas, liquid or solid), will endanger the GYE99 chromatographic analyzer materials and components, should be avoided. Install the GYE99 test bed of chromatographic analyzer must be steady. The vibration of the test bench will affect the stability of the instrument. In order to remove the hot air from the column furnace, at least 30cm of space should be left behind the instrument (and no flammable items are placed behind it) And 30 - 40cm passages for the installation and maintenance of chromatograph.
- Q: What are the commonly used instruments in biological laboratories?The company is planning to expand the laboratory instrument business
- Culture processIncubator series (US SI)Biosafety cabinet / over clean bench (Telstar, Baker, thermo)Fermenter (infors, labconco)Shaking table (IKA, INFORS, LAB-LINE)Water bath (LABSCAN, JULABO)Bottle turning machine (WHEATON, IBS)PCR (thermo, epondorf, ABI, BIO-RAD, MJ)Enzyme labelling apparatus (Awareness, epondorf, ABI)
- Q: What is the working principle of chromatographic analyzer?
- The central base type instrument is a chromatographic column box, the upper right side is a microcomputer temperature controller, on the right side of the lower part is a FID micro current amplifier, instrument left flow control components and pneumatic panel, pillar box at the top right part is ionization detector installation location (basic installation of two flame ionization detector) and thermal conductivity detector (TCD) the installation location is double column box above the left column injector or capillary injector.
- Q: Analytical instruments, laboratory supplies, agricultural materials, which industry prospects for development?
- Maintenance analysis instrument is better, because now do this line is not much, I now in an analytical instrument repair company to work, the profit is still considerable!
- Q: Why is chemical analysis more accurate than instrumental analysis?
- For example, for example, the error is 1, then the relative error of the chemical analysis may be 1%, and the instrument analysis may be 10%.
- Q: What are the analytical instruments in a chemical plant?
- Chemical analysis instruments include analytical components: chromatographic analyzers, etc.Water analyzer for analyzing water contentInfrared analyzer for analyzing carbon dioxide content and so on
- Q: Beauty salons with instruments to clear up clogged pores, skin care products can absorb better, reliable?
- Do not often wash your face with a brush, the good skin will be thin. But once every 2 weeks is OK, and the skin can repair itself during that time.Usually wash your face sooner or later have to wash, to clean thoroughly with moisturizing whitening farewell Cleansing Cream, that is not washed clean residue. Also do not use frosted cleanser, grinding really pain ah. After washing, you must apply the essence of shrink pores, or else go out and go into the dirt again.
- Q: What are the specific methods of chemical instrument analysis?
- A chemical analysis is a method of determining the composition and content of a substance to be measured by using a chemical reaction and its measurement relationship.
- Q: What is the working principle of the ICP Analyzer?
- Mainly used for the analysis of trace elements, analysis of the elements for most of the non metal metal and silicon, phosphorus, sulfur and other small, a total of 72. Widely used in the quality control of elemental analysis, detection of ultra trace elements, especially the water quality monitoring in the field of environmental protection. It can be used to detect the major elements. For example, component measurement, the main component elements were determined.
Send your message to us
Handheld precious metals analyzer
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords