• Ground-sourcing Heat Pump LGN R407C System 1
  • Ground-sourcing Heat Pump LGN R407C System 2
  • Ground-sourcing Heat Pump LGN R407C System 3
Ground-sourcing Heat Pump LGN R407C

Ground-sourcing Heat Pump LGN R407C

Ref Price:
get latest price
Loading Port:
SHANGHAI Port
Payment Terms:
100% TT
Min Order Qty:
1 Unit unit
Supply Capability:
1000 Unit Per Year unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications Of Ground-sourcing Heat Pump LGN R407C

Details Of Ground-sourcing Heat Pump LGN R407C

 

Model

GSQ-13WH

GSQ-22WH

GSQ-25WH

GSQ-38WH

GSQ-44WH

GSQ-88WH

GSQ-100WH

Cooling Capacity

KW

9

15

18

26

30

60

75

BTU/H

30717

51195

61434

88738

102390

204780

255975

Heating capacity

KW

13

21.5

25

38

44

88

100

BTU/H

44369

73379.5

85325

129694

150172

300344

341300

Water output

L/h

240

470

530

760

940

1800

2100

Refrigerant

Type

R410A or R407C

Weight

Kg

2.2

3.2

3.4

2.6*2

3.4*2

6.8*2

7.5*2

Control method

outside force balance type thermal expansion valve

Power supply

V/HZ

220(380)1(3)/50

220(380)1(3)/50

380/3/50

380/50

380/50

380/50

380/50

Protection function

High and low pressure,  high and low water output, overload, open phase, antiphase, over and lack pressure, anti-frost

Max.operation Current

A

10

13.2

15.5

17.5

33

53

65

Compressor

Type

   EVI Scroll

pcs

--

1

1

2

2

2

4

4

Input power

Cooling

2.2

3.8

4.3

6.5

9

15

17

(KW)

Heating

2.6

4.6

5.2

8.4

11

18

21

The heat source-side heat exchanger

Type

High efficiency spiral pipe heat exchanger 

Water resistance pressure

KPa

38

43

45

50

55

58

58

Water flow

M3/h

2.1

3.5

4.2

5.8

7

15.2

19.3

Connection size

DN

25

32

32

40

40

65

65

Use of side heat exchanger

Type

High efficiency spiral pipe heat exchanger 

Water resistance pressure

KPa

38

43

45

50

55

58

58

Water flow

M3/h

2.5

4.1

5

6.8

8

15.2

19.3

Connetion size

DN

25

32

32

40

40

65

65

Weight

Kg

90

135

155

250

290

600

660

Dimension(LXWXH)

mm

800X650X1100

1000X650X1280

1450X850X1350

Noise

dB(A)

40

45

45

46

48

50

52

Heating: Using Side Water Temp.(In/Out): 30°C/35°C; Heat Source Water Temp.(In/Out): 10°C/6°.
Cooling: Using Side Water Temp.(In/Out):  12°C/ 7 °C;Heat Source Water Temp.(In/Out): 30°C/35°C
The above data is for reference only: specific data is subject to the product nameplate.

 

Advantage Of Ground-sourcing Heat Pump LGN R407C

1.Heating,cooling and daily hot water
In winter, the unit will provide heat for house heating and domestic hot water.
In summer,the unit will provide cooling.
2.Heat capacity range from 13KW to 100KW or 44369 Btu/H to 341300 Btu/H
3.Advanced heat pump technology of High Cop up to 5 or above can Save more than 80% energy consumption compared to traditonal heaters,eg.electric boiler,gas boiler,geyser.
4.Not produce watse, contributuion to CO2 emission control.
5.Intelligent digital control gives you a comfortable operation ( SCADA modbus protocol option )
6.Safe operation with protection functions of high pressure, low pressure, overheating, overload, anti-freezing, phase monitor for three phases.
7.Extremely silent operation with good noise insulation, vibration isolation of the entire refrigeration system and water system.
8.Compact structure for less space occupation and good demountability Easy installation and maintenance
9.Long working life by using brand partsof flexible Japan Hitachi or Sanyo flexible scroll compressor, America Emerson ALCO thermal expansionvalve,Germany stainless steel plate heat exchanger, long working life up to 15 years.
10.IPX4 with good anti-corrosion: durable coating with special case design by using stainless steel bolts and nuts.
11.Warranty: 12 months guarantee for the whole unit.
12.Heat pump production as per Europe EN14511:2007,Product have CE approval and its working efficiency is Certified by TUV.

 

Packaging & Delivery Of Ground-sourcing Heat Pump LGN R407C

Packaging Detai

Packaging Detail Carton and Pallet or As customer request.

Delivery Detail10-15days

 

Usage/Application Of Ground-sourcing Heat Pump LGN R407C

1. Controller of Siemens,Italy ElWELL, CAREL available for Remote keyboard ( indoor control panel).
2. Plate heat exchanger of Sweden SWEP.
2. Germany WILO water pump and SIKA water flow switch from Germany ensure the good quality product.
3. Thermostatic expansion valve or electronic expansion valve.
4. Environmental R410A or R407c refrigerant.
5. Housing color With Silver, Grey, Cream.
ound source heat pump

We mainly use Copeland scroll compressor, it's high efficiency, low noise, stable, and long lifetime.We use plate heat exchanger.The heat pump can work automatically after the first time setting. It’s easy and convenient to use. 

 

 

 

Q:Can a solar water heater provide hot water during cloudy days?
Yes, a solar water heater can still provide hot water during cloudy days. While the efficiency may be reduced compared to sunny days, solar water heaters can still harness the available sunlight and convert it into heat energy to warm the water.
Q:What is the impact of corrosion on the performance of a solar water heater?
Corrosion can significantly affect the performance of a solar water heater. It can cause damage to the components such as the pipes, heat exchangers, and tanks, leading to leaks and decreased efficiency. Corrosion can also hinder the transfer of heat, resulting in reduced heating capacity and increased energy consumption. Regular maintenance and the use of corrosion-resistant materials are important to mitigate the impact of corrosion on the performance of a solar water heater.
Q:Can a solar water heater be used in areas with limited access to tidal power?
In areas where tidal power is limited, a solar water heater can be used instead. Tidal power generates energy from ocean tides, while a solar water heater uses the sun's energy to heat water. These two energy sources are independent and can be used separately. Solar water heaters are a sustainable and renewable technology that can be installed in any area with sufficient sunlight. They capture the sun's energy through solar panels or collectors, which heat the water in a storage tank. This heated water can be used for bathing, cooking, or space heating. Therefore, even in areas without access to tidal power, solar water heaters are an excellent alternative. They provide hot water, reduce reliance on fossil fuels, and lower energy costs. They are particularly beneficial in remote or off-grid locations where electricity supply may be limited or unreliable. In conclusion, while certain areas may not have tidal power, solar water heaters offer a viable and environmentally friendly solution for hot water needs.
Q:Can a solar water heater be used in areas with shading from trees or nearby buildings?
Yes, a solar water heater can still be used in areas with shading from trees or nearby buildings. However, the efficiency of the solar water heater may be reduced due to the decreased access to direct sunlight. It is important to ensure that the solar panels are positioned in an area where they receive maximum sunlight throughout the day to maximize the heater's performance.
Q:Can a solar water heater be used in areas with limited access to professional installation services?
Yes, a solar water heater can be used in areas with limited access to professional installation services. Solar water heaters are relatively simple systems and can often be installed by individuals with basic technical knowledge. There are also resources available, such as DIY guides and online tutorials, that can help individuals in such areas to install and maintain solar water heaters themselves.
Q:Can a solar water heater be used in areas with high levels of dust or debris?
Yes, a solar water heater can still be used in areas with high levels of dust or debris. However, it is important to regularly clean and maintain the solar panels to ensure optimal performance. Dust or debris accumulation on the panels can reduce their efficiency and affect the heating capacity of the system.
Q:Can a solar water heater be used in areas with limited access to clean water?
Yes, a solar water heater can be used in areas with limited access to clean water. The solar water heater relies on sunlight to heat water, making it independent of the quality of the water source. It can be used with any available water source, be it freshwater, brackish water, or even water from rivers or ponds. However, it is important to note that the solar water heater only heats the water and does not purify it. Therefore, additional water treatment methods may be necessary to ensure the water is safe for consumption.
Q:What is the impact of water hardness on the performance of a solar water heater?
The impact of water hardness on the performance of a solar water heater can be significant. Hard water contains high levels of minerals such as calcium and magnesium, which can lead to the formation of scale deposits inside the heater's pipes and components. These scale deposits can reduce the efficiency of heat transfer, leading to decreased performance and potentially higher energy consumption. Additionally, the accumulation of scale can also restrict water flow, resulting in reduced water pressure and slower heating times. Regular maintenance and the use of water softeners or descaling agents can help mitigate these issues and ensure optimal performance of the solar water heater.
Q:Can a solar water heater be used in areas with limited solar radiation?
Yes, a solar water heater can still be used in areas with limited solar radiation. However, the efficiency and performance of the solar water heater may be reduced in such areas. It is advisable to assess the solar potential of the specific location and consider alternative heating options if the solar radiation is significantly limited.
Q:Solar water heater tube or tube good
High efficiency, large water storage capacity, is now a large pipe
We are a leading manufacturer of a broad range of ground-sourcing heat pump.Our headquarter is in France.Over the past few years, we has enjoyed unprecedented growth due in large part to the support of our valued customers.

1. Manufacturer Overview

Location Shanghai,China
Year Established 1989
Annual Output Value US$2.5 Million - US$5 Million
Main Markets "

Asia;Western Europe;North Africa"
Company Certifications We are a leading manufacturer of a broad range of ground-sourcing heat pump. Over the past few years, we has enjoyed unprecedented growth due in large part to the support of our valued customers.

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai
Export Percentage 1% - 10%
No.of Employees in Trade Department About 1000
Language Spoken: English;Chinese
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords