• Fire Resistant Flexible Aluminum Duct System 1
  • Fire Resistant Flexible Aluminum Duct System 2
  • Fire Resistant Flexible Aluminum Duct System 3
  • Fire Resistant Flexible Aluminum Duct System 4
Fire Resistant Flexible Aluminum Duct

Fire Resistant Flexible Aluminum Duct

Ref Price:
$1.00 - 10.00 / m get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 m
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Semirigid Insulated Aluminum Flexible Duct Fire Resistant Flexible Aluminum Duct

1.Structure of Fire Resistant Flexible Aluminum Duct

Flexible air ducts are typically made of flexible plastic over a metal wire coil to shape a tube. And they have a variety of configurations. Flexible ducts are very convenient for attaching air outlets to the rigid ductwork. It is commonly attached with long zip ties or metal band claps. Besides, flexible ducts can tolerate moderate negative pressures.

2.Main Features of Fire Resistant Flexible Aluminum Duct

-Applied in air conditioning/ventilation systems

-Tear and puncture resistant

-Corrosion resistant

-High flexibility

-Convenient installation

-No toxic gas emission

3. Fire Resistant Flexible Aluminum Duct Images

 

 

Fire Resistant Flexible Aluminum Duct

4. Fire Resistant Flexible Aluminum Duct Specification

Insulated Flexible Duct

Structure: 1 layer of Aluminum Foil+1 layer PET film+insulated glass wool

Outer jacket: 1 layer of Aluminum Foil

Glass Wool Density: 16kg/m3; Thickness: 25mm

Insulated Acoustic Flexible Duct

Structure: 1 layer of Aluminum Foil +1 layer PET film+ insulated glass wool

Outer jacket: 1 layer of Aluminum Foil + 1 layer of PET film

Glass Wool Density: 32kg/m3; Thickness: 25mm

Specification

Type 1

Material

Aluminum foil

Structure

Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire.

Application

Suitable for medium-low air speed

Technical Parameter

Size

4”-16”

Standard Length

10m

Maximum Air Speed

20m/s

Maximum Heat Resistance

-20℃-150℃

Maximum Pressure

250mmWG

 

Type 2

Material

Aluminum foil

25mm thickness ,16kg/m3 glass wool.

Structure

Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire.

Insulating layer is covered by 25mm thickness ,16kg/m3 glass wool.

Outside layer: Reinforced aluminum foil;

Inside layer: Glass fiber mesh

Application

Suitable for medium-low air speed and low temperature difference.

 

Technical Parameter

Size

4”-5”, 6”-12”, 14”-16” 

Standard Length

7m, 10m

Maximum Air Speed

20m/s

Maximum Heat Resistance

-20℃-150℃

Maximum Pressure

250mmWG

 

Type 3

Material

·Aluminum foil

· 25mm thickness ,24kg/m3 glass wool.

Structure

· Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire.

· Insulating layer is covered by 25mm thickness ,24kg/m3 glass wool.

· Outside layer: Reinforced aluminum foil;

Inside layer: Glass fiber mesh

Application

Suitable for medium-low air speed and large temperature difference.

 Technical Parameter

Size

6”-12”

Standard Length

7m

Maximum Air Speed

20m/s

Maximum Heat Resistance

-20℃-150℃

Maximum Pressure

250mmWG

 

5.FAQ

We have organized several common questions for our clientsmay help you sincerely

1.How long for the delivery time?

Delivery time: 10-30 days, it depends on the ordered quantity.

2.What’s the usage

Practicality: suitable for the densely-populated area(such as school, supermarket, office, stadium, theater, factory.),high requirement of the environment area, such as hospital, laboratory, howff, bus, train, broadcasting studio. main usage: 1) Cold, hot water supply facilities for public buildings 2) Food, chemical, electronic industrial pipeline networks such as pipeline networks for transporting all kinds of corrosive liquid 3) Drinking water production system pipeline networks such as pure water and mineral water 4) Air conditioning facility pipeline 5) Compressed gas pipeline networks for industry 6) Pipeline network for swimming pool 7) Pipeline network for solar energy facility 8) Agriculture and garden production Additional information

How you control the quality?

During the production of fiberglass insulation, material is sampled at a number of locations in the process to maintain quality.

 

 

 

Q: Such as the problem, and now air-conditioning technology is mature, the market a lot of air conditioning are cold and warm, and I would like to be able to put my home that the end of the century loaded Mitsubishi air conditioning (split single cold) into a cold Before the conversion of ordinary TV to the remote control, that air conditioning can be modified? How much does it cost? Where is this technology? More
External wall insulation should pay attention to what the details?
Q: If I feel the room cool off, one hour hot and open an hour this will be more expensive? More
After learning that feel boring, to diverted it, brush point repair it. Architectural design institute will need to design equipment (that is, plumbing) design talent, that is, will generally participate in architectural design, the wages should be
Q: Air to water heater host and air conditioning host is not the same
Issued a test report, Detection can be used to pass, failed to use!
Q: Air conditioning ventilation when the sound is a big reason
Buried plastic pipe under external load, the diameter of the vertical diameter deformation rate should be less than the allowable diameter of the pipe deformation rate The diameter of the allowable diameter of the pipe shall not be greater than 5% The diameter deformation rate of the pipe and the allowable diameter deformation rate are calculated as follows: ε ΔD / D0 × 100% [ε] ε0 / K where: εΔD pipe in the combined load (Mm) [ε] Permissible diameter Deformation rate ε0 Elastic diameter Deformation rate (%) of pipe, by the flattening of the diameter of the pipe diameter (mm) The test determines the K safety factor, generally desirable 15
Q: US direct mail dysonhp01 Dyson air purification cooling machine triple in the country to warranty it
Among them, the extruded polystyrene gypsum composite board is based on paper gypsum substrate, the use of adhesive and extruded polystyrene board through the factory processing compound
Q: Do 3cm thick wall insulation how much kilogram of slurry and how many kilograms of polystyrene particles
Of course, is heating electricity. Heating has auxiliary electric heating, so electricity and electricity. Frequently open the fee, the air compressor is not good. 2 machine cooling power is 1700 watts, 1 hour is 1.7 degrees electricity. Heating with auxiliary electric heating power of 1500 watts, 1 hour is 3.2 degrees electricity.
Q: External wall insulation method of operation There are several combinations of materials
Seeking the existing building construction specifications Daquan! The The @
Q: The installation method of ordinary air conditioner. The more detailed the better. Please thank you all
2.1.23 step distance liftheight the distance between the upper and lower horizontal axis of the axis of each other. 2.1.24 pole vertical (cross) distance longitudinal spacingofuprighttube Scaffolding vertical distance between adjacent rods. 2.1.25 Vertical distance transversespacingofuprighttube Scaffolding Horizontal distance between adjacent vertical rods, single row scaffolding for the outside pole axis to the wall distance.
Q: In the design, the building structure and the hydropower are generally designed by the Architectural Design Institute. The air conditioning ventilation is based on the design of the room. Or first air conditioning ventilation? More
Aluminum alloy metal shell better than the plastic shell; we all know that most of the market is now charging the lithium battery, lithium battery is the only drawback is the possibility of a long time with the explosion, so the use of aluminum Alloy shell, much better than steel; polymer battery is good, but the price is expensive,
Q: HVAC Heating: What are the main components of the air distribution system?
The reasons are the following: 1. Household electricity is not enough, can not start the compressor, so in the heating state can only be ventilated state, cooling the state directly jump electricity; 2. See if you are reported failure, Code to determine the need for on-site inspection in order to know the specific situation; 3. Four-way valve should be no problem, do not just believe that this is the problem Oh; help your words to adopt