F7 PFIM Series RCCB
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
*20 years of experience in manufacturing
*10 years of experience in export
*Factory & Trading
*Good price
*Good Quality
TECHNICAL DATA:
F7 PFIM RCCB RCD ELCB
PARAMETER | RATING |
Type | Electro-magnetic, Electronic |
Number of poles | 2P 4P |
Rated making and breaking capacity | 630A |
Rated Current(In) | 6, 12, 25, 32, 40, 63, 80, 100A |
Rated Voltage(Un) | AC 2P: 230/240V 4P: 400/415V |
Rated residual operating current( In) | 30 100 300 500mA |
Rated residual non-operation Current( Ino) | 0.5In |
Residual operating current scope | 0.5In~In |
Residual current breaking time | ≤ 0.3s |
Residual current trip characteristics | A, AC |
Ultimate short-circuit breaking capacity (Inc) | 4KA 4.5KA 6KA 7.5KA 10KA |
Endurance | ≥ 4000 |
Connection Capacity | ≤ 25mm 2 |
Connection terminal torque (Max. ) | 2.0Nm |
Degree of protection | IP20 |
Standard | IEC/EN610018 |
APPLICATION
TOR series ( F7 PFIM RCCB RCD ELCB ) circuit breaker,are designed for protection of humans and animals against the dangerous effects of electriccurrent.
When parts under voltage are touched, the RCD instantly switches off the current long before any amount or duration of current flow can cause damage.
Such fields of application are ,e.g.,rooms with bath tubs or shower, saunas, indoor and outdoor swimming pools, farming facilities, outdoor sockets, etc.
- Q: What circuit symbols are used for circuit breakers
- that is, by the internal cycle of the protection and algebra and (including the neutral current neutral current instantaneous three-phase
- Q: What is the choice of low voltage electrical circuit breaker?
- n addition, due to the internal locking mechanism of the thermal circuit breaker, it is extremely insensitive to shock and vibration.
- Q: Circuit system diagram how the circuit breaker said
- Therefore, the disconnector can only be in the circuit has been broken when the circuit breaker to operate, is strictly prohibited with the load operation
- Q: Is the zero line going through the circuit breaker?
- Three-phase four-wire zero line is absolutely not allowed to go through the circuit breaker, because the zero line is broken, the line of all 220V appliances will withstand 380V line voltage and burned.
- Q: How to distinguish between disconnectors, circuit breakers?
- In the closed state can be reliably through the normal load current and short circuit fault curren
- Q: How to switch from the circuit breaker switch button, the difference is short circuit protection or overload protection?
- It acts as a knife switch. Fuse thermal relay and other electrical appliances
- Q: Do you have a circuit breaker in the circuit?
- Of course, there are many problems in practical applications, this is just an example.
- Q: The difference between the leakage switch of the air switch circuit breaker
- Mainly used for short circuit and overload protection. General 1P1P plus N or 2P. 3P or 4P, etc.
- Q: Is the isolator switchable with a circuit breaker?
- Disconnector: similar to the knife switch, no to prevent overcurrent, short circuit function, no arc device;
- Q: Is there a circuit breaker in the circuit
- Fuse and circuit breaker function is the same, are used in electrical equipment in the event of overload and short circuit and other failures play a protective role
1. Manufacturer Overview
Location | Zhejiang,China (Mainland) |
Year Established | 1993 |
Annual Output Value | US$2.5 Million - US$5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Central America; Northern Europe; Southern Europe; South Asia; Domestic Market |
Company Certifications | ISO 9001:2000;ISO 9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | Above 50 People |
Language Spoken: | English, Chinese, Spanish |
b) Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
F7 PFIM Series RCCB
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches