F7 PFIM Series RCCB
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
*20 years of experience in manufacturing
*10 years of experience in export
*Factory & Trading
*Good price
*Good Quality
TECHNICAL DATA:
F7 PFIM RCCB RCD ELCB
PARAMETER | RATING |
Type | Electro-magnetic, Electronic |
Number of poles | 2P 4P |
Rated making and breaking capacity | 630A |
Rated Current(In) | 6, 12, 25, 32, 40, 63, 80, 100A |
Rated Voltage(Un) | AC 2P: 230/240V 4P: 400/415V |
Rated residual operating current( In) | 30 100 300 500mA |
Rated residual non-operation Current( Ino) | 0.5In |
Residual operating current scope | 0.5In~In |
Residual current breaking time | ≤ 0.3s |
Residual current trip characteristics | A, AC |
Ultimate short-circuit breaking capacity (Inc) | 4KA 4.5KA 6KA 7.5KA 10KA |
Endurance | ≥ 4000 |
Connection Capacity | ≤ 25mm 2 |
Connection terminal torque (Max. ) | 2.0Nm |
Degree of protection | IP20 |
Standard | IEC/EN610018 |
APPLICATION
TOR series ( F7 PFIM RCCB RCD ELCB ) circuit breaker,are designed for protection of humans and animals against the dangerous effects of electriccurrent.
When parts under voltage are touched, the RCD instantly switches off the current long before any amount or duration of current flow can cause damage.
Such fields of application are ,e.g.,rooms with bath tubs or shower, saunas, indoor and outdoor swimming pools, farming facilities, outdoor sockets, etc.
- Q:Circuit problem! Hurry Miniature Circuit Breaker!
- such as the access line loose, due to contact resistance becomes larger, will cause heat to make the circuit breaker malfunction.
- Q:How long is the circuit breaker long delay time?
- Circuit breaker (English name: circuit-breaker, circuit breaker) is able to close, carry and break the normal circuit under the conditions of the current and can be closed,
- Q:Double control switch circuit diagram
- constitute the electrical connection of the circuit are called secondary circuit or secondary wiring
- Q:s the MCB switch a circuit breaker or a component on the circuit breaker?
- with leakage protection This function is used in the total switch circuit breaker or used in the branch circuit breaker better, personal understanding of the total circuit breaker
- Q:Does the isolator and circuit breaker able to switch to each other?
- When the circuit breaker disconnect the live circuit, the internal contact in the separation of the moment will produce an arc, the higher the voltage or the greater the current, the stronger the arc.
- Q:What is the length of time that the circuit breaker can delay?
- do not know what kind of circuit breaker you said. Long delay function in general is a trip time and overload current into inverse time relationship
- Q:Circuit system diagram how the circuit breaker said
- Therefore, the disconnector can only be in the circuit has been broken when the circuit breaker to operate, is strictly prohibited with the load operation
- Q:Is the isolator switchable with a circuit breaker?
- the disconnector can not be used to turn on or off the current, it is only broken in the case of breaking the circuit breaker, to provide a "clear break point."
- Q:Why the first break circuit breaker, after the isolation switch off it?
- Power failure, the circuit there is current, because the circuit breaker has the ability to arc, the first pull circuit breaker, there will be no problem,
- Q:How to look at the circuit breaker capacity is how much?
- The rated breaking current of the circuit breaker is three times the root number of the product of the rated voltage, that is, the blocking capacity.
1. Manufacturer Overview |
|
---|---|
Location | Zhejiang,China (Mainland) |
Year Established | 1993 |
Annual Output Value | US$2.5 Million - US$5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Central America; Northern Europe; Southern Europe; South Asia; Domestic Market |
Company Certifications | ISO 9001:2000;ISO 9001:2008 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | Above 50 People |
Language Spoken: | English, Chinese, Spanish |
b)Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
F7 PFIM Series RCCB
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches