F7 PFIM Series RCCB
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
*20 years of experience in manufacturing
*10 years of experience in export
*Factory & Trading
*Good price
*Good Quality
TECHNICAL DATA:
F7 PFIM RCCB RCD ELCB
PARAMETER | RATING |
Type | Electro-magnetic, Electronic |
Number of poles | 2P 4P |
Rated making and breaking capacity | 630A |
Rated Current(In) | 6, 12, 25, 32, 40, 63, 80, 100A |
Rated Voltage(Un) | AC 2P: 230/240V 4P: 400/415V |
Rated residual operating current( In) | 30 100 300 500mA |
Rated residual non-operation Current( Ino) | 0.5In |
Residual operating current scope | 0.5In~In |
Residual current breaking time | ≤ 0.3s |
Residual current trip characteristics | A, AC |
Ultimate short-circuit breaking capacity (Inc) | 4KA 4.5KA 6KA 7.5KA 10KA |
Endurance | ≥ 4000 |
Connection Capacity | ≤ 25mm 2 |
Connection terminal torque (Max. ) | 2.0Nm |
Degree of protection | IP20 |
Standard | IEC/EN610018 |
APPLICATION
TOR series ( F7 PFIM RCCB RCD ELCB ) circuit breaker,are designed for protection of humans and animals against the dangerous effects of electriccurrent.
When parts under voltage are touched, the RCD instantly switches off the current long before any amount or duration of current flow can cause damage.
Such fields of application are ,e.g.,rooms with bath tubs or shower, saunas, indoor and outdoor swimming pools, farming facilities, outdoor sockets, etc.
- Q: Home no electricity corridor switch the total switch circuit burned how the matter
- such as wiring crush is not strong, resulting in electricity when the heat, accumulated to a certain situation, burn the switch.
- Q: s the MCB switch a circuit breaker or a component on the circuit breaker?
- then if any branch of the circuit breaker circuit breaker circuit breaker will cut off the total circuit breaker All the power supply, if used in the branch circuit breaker will not affect the normal use of other branch electrical appliances
- Q: How is the total switch breaker in the distribution box correctly
- such as leakage or physical impact is achieved through the sensing element to its leakage or electric shock leakage
- Q: Which is the circuit switch, that is the circuit breaker
- so the frame circuit breaker and molded case circuit breaker applications are different occasions, the framework used in the higher into the line, molded case applied to the lower level of the framework.
- Q: How to distinguish between disconnectors, circuit breakers?
- Because it does not have a special arc extinguishing device, can not cut off the load current and short circuit current.
- Q: How to choose a circuit breaker for home and small office circuits
- Leakage accessory handle. Leakage causes not removed before the small circuit breaker handle and leakage accessory handle can not be reset.
- Q: Home circuit breakers and how much air is open
- the principle of air switch, the function of the general situation for the customer matching distribution box in the process, should be in a small lighting, socket, air conditioning large matching principle
- Q: How to look at the circuit breaker capacity is how much?
- but the circuit is not broken, must be arc to completely disconnect the circuit current, so the circuit breaker circuit is completely broken circuit called shut-off.
- Q: What is the specific function of the auxiliary switch on the circuit breaker switch?
- Used to control, protect, adjust, measure and monitor the parameters of the circuit and the working conditions of each component.
- Q: Is it possible to switch the lamp directly with a circuit breaker?
- Circuit breakers can be used to distribute power, not frequently start the asynchronous motor, the power lines and motors and other protection, when they have a serious overload or short circuit and undervoltage failure can automatically cut off the circuit, its function is equivalent to the fuse switch
1. Manufacturer Overview
Location | Zhejiang,China (Mainland) |
Year Established | 1993 |
Annual Output Value | US$2.5 Million - US$5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Central America; Northern Europe; Southern Europe; South Asia; Domestic Market |
Company Certifications | ISO 9001:2000;ISO 9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | Above 50 People |
Language Spoken: | English, Chinese, Spanish |
b) Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
F7 PFIM Series RCCB
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches