• Ductile Iron Dual Plate Wafer Check Valve System 1
  • Ductile Iron Dual Plate Wafer Check Valve System 2
  • Ductile Iron Dual Plate Wafer Check Valve System 3
Ductile Iron Dual Plate Wafer Check Valve

Ductile Iron Dual Plate Wafer Check Valve

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Cast iron valves
Size: DN40-1200 or 1.5-48' or above
Working Pressure: PN10/16/20/25, 150LB-2500LB
Suitable temperature: -45c~150c
Standard:
(1)Design and manufacture: DIN3352, BS5163, BS5150, ANSI B16.34, API600, API6D, API609, EN593, GB, T12238
(2)End connection: ANSI B 16.1, ASME B16.5, B16.47, B16.25, B16.34, JISB2212-JISB2214, DIN2543-2550, EN1092, AS2129, ISO 5211
(3)Wall thickness: API600, BS1868
(4)Face to face (end to end): EN 558, ASME B16.10, DIN3202, ISO5752, JIS, API609, MSS, BS5155
(5)Inspection and test: API598, EN12266-1, BS6755, API6D, ISO5208
Materialfor main parts:
(1)Body: CI, DI, WCB, ALB, CF8, CF8M
(2)Disc: DI, ALB, C95400, Rubber lined Disc, 1.2501, 1.4529, CF8M, CF8, Hastelloy
(3)Stem: SS416, SS410, SS304, SS431
(4)Seat: NR, Hypalon, EPDM, Neoprene, NBR, Wear-Resistant EPDM, Viton, Silicon, Heat-Resistant EPDM, WhiteNBR, WhiteEPDM, EPDM, PTFE
Coating: Fusion bonded epoxy coated
Connection type: Flanged type, Push-on type, Mechanical Joint type, Plain ends type
Sealing: Soft sealing or metal-to-metal seat, Flexible graphite
Operation: Manual, Pheunatic, Electric, Hydraulic and Pnewmatic-Hydraul
Appropriate medium: Air, water, sewage, steam, coal gas, oil
Packaging: Export polywood cases, or as per customers' requirements
Application: Fresh water, sewage, sea water, air, vapor, food, medicine, oils. Acids, alkalis, salt etc.

ItemWafer type check valve
StandardDIN/ANSI/BS
Body materialCI/DI/CS
Disc materialSS
Pressure  PN16/CLASS125

Q: DN20 copper ball valve with large PPR converter connector
What do you see a ball valve, PPR ball valve, ball valve with internal screw threads, ball valves, but if you look at the butt of the ball size, if the ball is 20. The tube is 20, then the 20*1/2 internal thread can be directly on the butt.
Q: Gate valve, ball valve, the difference between the pressure regulating valve
Gate valve and stop valve are shut-off valve, is the most common two valves. From the exterior, the gate valve is shorter than the cut-off valve, especially the bar valve needs a higher height space. Valve sealing surface has a certain degree of self sealing capacity, its spool depends on the media pressure tight contact with the valve seat sealing surface, to achieve tight leakage. Wedge gate valve spool angle is generally 3~6 degrees, when forced to shut down excessive or temperature changes of the valve core is easy to die. Therefore, high temperature and high pressure wedge gate valve, in the structure have taken certain measures to prevent spool stuck. The valve in the opening and closing valve and valve seat sealing surface contact and mutual friction is always so easy to wear sealing surface, especially in close off the valve, the valve before and after the great pressure, sealing surface wear is more serious. Compared with the cut-off valve, the main advantage is that the flow resistance is small, the flow resistance coefficient of ordinary gate valve is about 0.08~0.12, while the ordinary cut-off valve resistance coefficient is about 3.5~4.5. Opening, closing force is small, the medium can flow in two directions.
Q: Maintenance of PPR pipe ball valve is live or hot melt?
The ball valve is defined with the ppR/PE hot melt plastic pipe connected with the ball valve hot melt connection, ordinary ball valves generally use the threaded connection or flange connection.Hot melt connection is widely used in PB pipe, PE-RT pipe and other new pipe connections.Hot melt connection has the advantages of simple connection, long service life and easy corrosion.PPR pipes can only be connected by hot melt. There is a dedicated connection PPR tube double union copper ball valve, ball valve is full of copper, on both sides with PPR live tab.Ball valve (in the field of marine engineering and ships should be cut-off valve), standard GB/T21465-2008 "valve terminology" is defined as: "open and close parts (spheres) driven by the stem, and around the axis of the ball valve to rotate the valve movement.". Can also be used to regulate and control fluid, strong shear force between the metal seat seal V type ball valve V type ball core and welding hard alloy, especially suitable for containing fibers, small solid particles and other media. Switch and multi way valve in the pipeline not only can flow, and flow diversion, flexible control of the medium, but also to turn off any channel to the other two channels. This kind of valve should be installed horizontally in the pipeline. In accordance with the way to drive the ball valve is divided into: pneumatic ball valve, electric ball valve, manual ball valve.Ball valve was introduced in 1950s, with the rapid development of science and technology, production process and product structure of continuous improvement, in a short span of 40 years, has rapidly developed into a major valve category. In western developed countries, the use of ball valves is increasing year by year.
Q: And the cut-off valve is not the general name of gate valve and butterfly valve?What are the signs of differentiation?How about the use?
When the valve is opened, the opening height of the valve is 25% to 30% of the nominal diameter, the flow has reached the maximum, which means that the valve has reached full open position, so the opening position of the stop valve should be determined by the stroke of the discThe cut-off valve has the following advantages:The utility model has the advantages of simple structure and convenient manufacture and maintenanceSmall travel time, short opening and closing timeGood sealing, friction between the sealing surface of small, long lifeThe disadvantages of the cut-off valve are as follows:The resistance of fluid is large, and the force required for opening and closing is largerNot suitable for medium with particle, viscosity and easy cokingPoor regulation performanceType valve stem according to the position of divided threaded screw type, internal thread. Divided by the flow of media, there are straight through, DC type and angle type. Divided by the form of valve seal, a packing seal bellows seal valves and valve.The installation and maintenance of the cut-off valve shall pay attention to the following matters:The stop valve operated by the handwheel and handle can be installed in any position of the pipeHand wheel, handle and steering mechanism are not allowed to be used for liftingThe flow direction of the medium shall be in accordance with the arrow shown in the valve body
Q: To help explain the meaning of the ball valve Q11H-16H, combined with the actual, such valves have wood?
JB T308-2004 valve model preparation method and "GB1048-2005 pipe element nominal pressure definition and selection", there are various types of valve interpretation:Q11H-16HQ: valve type: (Q) ball valve1: connection form: (1) internal thread1: structure form: (1) through flow channelH: sealing surface or lining material: (H) Cr13 stainless steel16: pressure code: (16) 1.6MPaH: body material: (H) Cr13 stainless steel
Q: The two valves are available for the flow of the electromagnetic valve switch, I contact more, found for water solenoid valve are caged water, to repair several times because of impurities or newly installed pipeline with raw materials flowing through the valve, close the valve body when not to rely on Yan, a seepage water tank to diffuse phenomenon!I am looking for a replacement, I think the electric valve should be a good choice, not used to a conclusion.Please use the electric ball valve to talk about friends, or for the two kinds of friends who have an understanding to talk aboutOr there is no better substituteThere seems to control the solenoid valve and electric valve is not the same, the solenoid valve is normally open and closed to control the electric valve is controlled by the trigger (like), if used to replace it, what is the controller?
Solenoid valve on the medium cleanliness requirements are very high, when the water is not clean, easy to leak. You use the solenoid valve is leaking, that's the case.If you have an air source, use pneumatic angle seat valvesIf only the power supply, the electric ball valve.Electromagnetic valve is electromagnetic rail, electric suction from the electromagnetic core, so that the valve openThe electric ball valve is driven by the motor to drive the valve open. If only switch, then do not need to install any controller, when buying, must explain is the switch ball valve.This answer was net friend adoption
Q: Three electric ball valve type T and type L what is the difference?
Three way ball valve generally adopts two seat structure, can also be used according to user requirements four valve seat structure. Four seat sealed three pass ball valve, with beautiful appearance, compact structure and reasonable
Q: Pneumatic two stage ball valve principle
By two pneumatic actuators and ball valve or butterfly valve, the piston stroke change additional cylinder, actuator and valve angle is stopped at a predetermined angle (45 degrees -90), so the valve flow can be adjusted. This device by two solenoid valve control valve flow. As the actuator uses the rapid exhaust and throttling function, so that the two segment ball valve has excellent switching characteristics. Slow open and close valve velocity, the fluid in the pipeline to change smoothly, not because of the impact of water hammer in the flammable fluid explosion, nor system flowmeter and other instruments damaged by the impact of the flow, it is suitable for the industries of petroleum, chemical industry, light industry, national defense and other control systems, especially suitable for oil storage and transportation system.
Q: How to distinguish between single and double ball valve?
Single ball valve, pneumatic ball valve is a single short; double valve, double acting pneumatic ball valve is referred to as.Single acting pneumatic ball valve is open air, spring off; and double acting pneumatic ball valve, gas gas is closed.Single / double ball valve, is divided according to the actuator, the actuator has a single pneumatic actuator and double acting pneumatic actuator.Single acting pneumatic actuator Pneumatic actuator to more than double spring, loss of gas supply, the spring to reset actuator.For hazardous media or conditions requiring a safe position when the gas source is lost, a single action is recommended.Selection must be based on the size of the field air pressure to select the spring force, otherwise it may cause air pressure is less than overcome the spring force and can not drive the actuator.When the actuator is selected, the minimum spring force should be allowed to drive the valve normally, taking into account the gradual reduction of the spring force.
Q: What does "q41f46-16c-dn40" mean?
DN40 refers to the nominal diameter, 16C represents 16 kg of pressure, carbon steel material F46 stands for fluorine