CNBM Ductile iron BS/DIN/ISO 2''
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery
Packaging Detail: | plywood case |
Delivery Detail: | 30days after recieve your deposit |
Specifications
1.Face to Face:BS5163
2.Material: Cast iron
3.Nominal Pressure: PN16
4.Stem Material:Stainless Steel
5.Flange End:2"-24''
Product Description
rising stem gate valve, metal seated gate valve
BS5163 gate valve
Cast iron gate valve
Rising stem gate valve,
Product name:
Rising stem gate valve
BS5163 gate valve
Cast iron gate valve
OS&Y gate valve
BS rising stem gate valve
BS gate valve
resilient seat gate valve
Material
Body: CI or DI
Disc: CI or DI
Seat: Brass/Bronze
Stem: stainless steel
Standard
Face to face: BS5163:1986,BS5150
Flange: BS 4504&BS10table E or D
Pressure
PN10/16
- Q: What do you mean by "2" and "200 CF8M"?
- CF8M is stainless steel, and 2 is caliber 50200 and should also be bore
- Q: The difference between cut-off valve and gate valve
- Structurally, the gate valve for the gate, down to the front and back seat seal; globe valve with spherical, taper and flat spool, down to the valve seat seal. Functional stop valves are generally used for pressure flow control. Gate valves are used for isolation.
- Q: What kind of gate valve is Z6CS-H102?
- Z== valve type: gate valve6== pressure rating: 800LB, API602C== structure: bolt connection, valve cover, bolt connection gland, bright rod support typeS== connection form: socket welding, that is, SWH1== body material: A10502== inner material: seat sealing surface STL, gate sealing surface STL, valve stem 13Cr
- Q: Z41T one 10 gate valve and Z44T one, 10 gate valve difference
- Z41T one, 10 is single gate, Z44T one, 10 is double gateAccording to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange type1== structure: Rigid single gate4== structure: Rigid double gateT== sealing surface material: copper alloy10== pressure rating: 1.0MPa
- Q: Is the gate valve clockwise or closed?
- In general, the valve is clockwise to turn off. Some of the clockwise rotation of the valve on the move is open
- Q: What are the structural differences between parallel and wedge valves?
- The advantages of dual gate plate is sealed and angle precision low temperature is not easy to make the wedge gate, the abrasion of the sealing surface and shim.The disadvantage is that the structure is complex, easy to stick in the dry medium, mainly the upper and lower baffles. After years of corrosion, the gate is easy to fall off. Although the single gate is sealed and angle accuracy requirements are relatively high, difficult processing and temperature change may make the gate wedge and other shortcomings, but has the advantages of simple structure, reliable use, especially to the flexible gate, can produce the micro elastic deformation to compensate for the deviation between the sealing surface angle processing, which is widely used at present.For more information about valves, please keep an eye on the valve knowledge section.
- Q: Function of gate valve
- The valve (including the valve and valve) is a fluid pipeline control device, its basic function is to connect or cut off the pipeline medium circulation, changing the medium circulation, change the direction of the flow medium, medium pressure and flow regulation, to protect the normal operation of pipeline equipment.
- Q: What are the differences between the gate valve and the cut-off valve?
- The operating principle is different. The stop valve is an upward stem type, and the handwheel rotates and rises with the stem. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open, the cut-off valve is not the same. The gate valve has no inlet and outlet direction requirements, and the cut-off valve has the required inlet and outletAt the same time, usually with the cut-off valve instead of gate valve, but the valve can also be used instead of cut-off valve. Valve sealing performance better, but the size is generally not large, the size of the gate valve can be done great.The main difference between them lies in:1, different structure, gate valve structure is more complex than the height, larger size, from the appearance point of view than the cut-off gate valve is short and high, especially the gate height space needs a higher open bar, the selection in the installation space under the condition of limited attention to.2, sealing surface, valve in the opening and closing valve and the valve seat surface always contact and friction between the sealing surface, and thus easy to wear, especially in close off the valve when the valve before and after the great pressure, sealing surface wear is more serious. And the valve once the valve is in open condition, it's seat and disc sealing surface between, not in contact,
- Q: What is the difference between a flanged gate valve and a wire gate valve?
- Threaded valve is via the wire or wire is connected with the pipeline, a small general air for the air valve, all belong to this
- Q: Why does the centrifugal pump start and stop in the case of closing the gate valve?
- The centrifugal pump starts and stops in the case of closing the pump outlet valve. Start off the pump outlet valve is to reduce the starting current, stop when the pump is closed, the outlet valve is to reduce water hammer, prevent blade from bad.
Send your message to us
CNBM Ductile iron BS/DIN/ISO 2''
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords