(Chunlan)Air conditioner KFR-32GW/VF2d-E2
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 30 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Quick Details
Condition: | New | Brand Name: | Chunlan | Place of Origin: | China (Mainland) |
Use: | Room | Power Source: | Electrical | Power Type: | DC |
Type: | Split Wall Mounted Air Conditioners | Cooling/Heating: | Cooling/Heating | Certification: | CE,RoHS |
Capacity (btu): | 10000 | EER: | 1.5 | Power (W): | 985 |
Voltage (V): | 220 | Model Number: | KFR-32GW/VF2d-E2 |
Specifications
1.create a quiet environment
2.refrigeration'effect is better
3.apperance is beautifull
1.Wall split air conditioner
2.Applicable area:15-22m2
3.Fixed frequency
4.Air-conditioner accessary:remote contral,Machine tube,outdoor machine,instruction
Model | KFR-32GW/VF2d-E2 | |
Power | 220/50Hz | |
capacity (BTU) | cooling | 10000 |
heating | 12000 | |
noise[dB(A)] | indoor | <29 |
outdoor | <41 | |
Net dimensions(mm) | indoor | 860*201*274mm |
outdoor | 760*259*537mm | |
net weight (kg) | indoor | |
outdoor | ||
Air circulation (m3/h) | cooling | |
heating |
- Q: Air conditioning is out of the air come in, or only in indoor cycle?
- Ordinary families with air conditioning is in indoor air circulation. Common air conditioning commonly referred to as "air" is the meaning of "ventilation", that is when the fan with air conditioning use, there is no fresh air, introduced from outside, in the process of work also do not have the ability to improve air quality. Current status, with the function of ventilation in the true sense, is directly from the introduction part of outdoor fresh air after filtering, air-conditioning into the room air conditioning products rarely, even with the function of the product its air filtration effect or the temperature effect is not ideal. For household wall air conditioning or cabinet air conditioning, the structure design is very compact, cost control is very strict, it's hard to do the central air conditioning can do wet air purification dust, temperature effect, because on this kind of air-conditioning installation of air filters filter level not too high, and small evaporator heat capacity design, product design is often only when "attend". If it is in the use of air conditioning temperature control to improve indoor air quality at the same time, can be equipped with air - air energy recovery device, that is, total heat exchangers to achieve discharge part of the indoor air, part of the fresh air, introduced from outside, at the same time also can recycle most of the energy, to improve the indoor air quality.
- Q: Air conditioning machine outside and inside of the machine, please use a power cord?
- General family expenses is so. But I say the second case, often apply to hotel KTV etc. Did your school because of electricity to the dormitory management regulations and adopt the way of power supply from outside the machine, it only depends on the mood of the school - ordinary household air conditioning can convert into machine power supply, the purpose is to let the dormitory no socket.
- Q: Open one night air conditioning degrees tend to use electricity
- How much is depends on the input power of the machine and how much is the set temperature and environmental temperature difference. 1 degree = 1000 watts per hour in theory, such as 1 machine horse power input (nameplate on the machine) is 850 watts, the power consumption 0.85 degrees per hour, due to the air conditioning automatic control temperature function, so the compressor is not always start, if stop and start time is 1:1, so the actual power consumption is about 0.43 degrees or so per hour, multiplied by the use of time.
- Q: What is the air conditioning refrigerant today
- Domestic mainly R22. A handful of high-end machines made in China is to destroy the atmosphere of R410 Joint venture is below 3800 are R22, higher than the price of R410 Whether the ship plane all cars use commercial air conditioning refrigerant freon.
- Q: Household air-conditioning ventilation principle is what
- In new wind function of household air conditioning has a ventilation tube and outdoor connected, form a negative pressure on indoor air, from the Windows and doors into the fresh air, and some medium such as activated carbon is used to deal with indoor air circulation
- Q: Air conditioning is divided into several types
- Roughly the fission and window machine. And there came of the changes in temperature and used by, and heat pump, electric auxiliary heating, etc.
- Q: Useful three-phase electric air conditioning is what kind of?
- Three-phase air-conditioning outside machine is electric heating and air conditioning compressor is 380 v voltage. To apply to the local power supply bureau, general installation meters must be replaced three phase meters. Need to choose according to use all electric appliance total power meters, choosing a meter power supply bureau will specify what to use electric meter. Socket is four holes, respectively is: A, B, C, PE (grounding protection). If A, B, C three-phase imbalance, N line at this moment, otherwise due to the zero line current exist, can produce A potential difference, endangering the personal safety
- Q: Can air conditioning filter pm2.5
- Can not when winter heating, summer cooling. Common household air conditioner indoor machine filter can filter the larger foreign body, filter filter itself is not the PM2.5 so tiny particles. But in summer air conditioning refrigeration operation time, the chance to generate condensate, indoor small particles in the air will be condensed water out of the outdoor.
- Q: How do you troubleshoot an air conditioner that is not blowing cold air?
- To identify and potentially resolve the issue of your air conditioner not blowing cold air, there are several troubleshooting steps you can take. Follow this step-by-step guide: 1. Ensure the thermostat settings are correct: Check that the thermostat is set to the appropriate temperature and cooling mode. Sometimes, the problem may simply be an incorrect setting. 2. Keep the air filter clean or replace it: A dirty or clogged air filter can restrict airflow and reduce the cooling efficiency of your air conditioner. Regularly clean or replace the filter to ensure proper airflow. 3. Examine the outdoor unit: Check if the outdoor unit (condenser) is obstructed by debris, leaves, or any other objects. Remove any obstacles and ensure the unit has enough space for proper airflow. 4. Inspect the indoor unit: Make sure the indoor unit (evaporator) is clean and free from dust or debris. If necessary, clean the unit and remove any obstructions around it. 5. Monitor the refrigerant level: Low refrigerant levels can lead to reduced cooling capacity. If you suspect a refrigerant leak, it is best to contact a professional HVAC technician to inspect and recharge the system. 6. Detect air leaks: Inspect the air ducts, vents, and connections for any leaks. Air leaks can decrease the cooling efficiency of your system. Seal any leaks with duct tape or call a professional technician for repairs. 7. Check the condensate drain line: Make sure the condensate drain line is not clogged. A blocked drain line can cause water buildup and impact the cooling performance. Clean the drain line or call a professional to remove any blockages. 8. Verify the circuit breaker: Check that the circuit breaker for your air conditioner is not tripped. If it is, reset the breaker and see if the unit starts blowing cold air. If these troubleshooting steps do not resolve the issue, it is recommended to seek assistance from a professional HVAC technician. They possess the necessary knowledge and tools to diagnose and repair complex air conditioning problems.
- Q: Air conditioning general how long does it take to add fluoride? My home air conditioning use for five years, like is not very good cooling effect, whether need to add fluoride?
- Condenser cleaning machine outside first, reoccupy pressure gauge can measure pressure and then determine whether crossroads freon, very bad is dirty
Send your message to us
(Chunlan)Air conditioner KFR-32GW/VF2d-E2
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 30 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches