CFE Utility ESS 2580Kwh- 3440Kwh Battries in containers
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 watt
- Supply Capability:
- 10000 watt/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
l ≤ 1 hour: Maintenance and replacement time is less than 1 hour
l ≥ 90%: System charging and discharging efficiency>90%
l ≥ 6000 cycles: The battery cycle life under energy storage conditions exceeds 6000 cycles
l High-performance PCS: Using high-efficiency three-level topology, Germany's seventh-generation IGBT, the highest efficiency can reach 99.3%
l High configuration system: Integrate high-speed communication, power distribution and metering, AC output adopts 2-level controllable switch + passive protection
l Actively balanced BMS: Adopt high-current high-efficiency two-way active equalization technology to eliminate series losses caused by inconsistent batteries
l Active safety system: Adopt intelligent environment control to ensure the best battery temperature, The 9-level active safety system ensures that the fire protection is controllable.
l Intelligent power distribution system: Integrating high-speed communication, electric power distribution and metering, AC output adopts 2-level controllable switch + passive protection.
System nominal | |||
Rated power | 500KW | 1000 KW | 1000 KW |
Nominal capacity | 2580KWh | 3010 KWh | 3440 KWh |
Communication side | |||
Rated voltage | 380V | 380V | 380V |
Rated current | 759A | 1500A | 1500A |
Rated frequency | 50HZ | 50HZ | 50HZ |
Power factor | >0.98 | >0.98 | >0.98 |
Wiring | Three-phase three-wire | Three-phase three-wire | Three-phase three-wire |
Isolation transformer | 630KVA | 1250KVA | 1250KVA |
Inrush current | Less than 7 times | ||
Harmonic distortion rate | Less than 3% (secondary side of transformer) | ||
DC side | |||
Rated voltage | 768V | 768V | 768V |
Lower limit voltage | 600V | 600V | 600V |
Upper limit voltage | 876V | 876V | 876V |
Rated current | 650A | 1300A | 1300A |
Cell specifications | 280Ah | 280Ah | 280Ah |
Number of batteries | 2880 | 3360 | 3840 |
Number of modules | 180 | 210 | 240 |
Module specifications | 1P16S | 1P16S | 1P16S |
Actual capacity | 2580KWh | 3010KWh | 3440KWh |
Battery management | |||
Cluster battery | 12 | 14 | 16 |
Cluster unit | 12 | 14 | 16 |
Voltage accuracy | 0.002 | 0.002 | 0.002 |
Temperature accuracy | 0.01 | 0.01 | 0.01 |
SOC accuracy | 0.05 | 0.05 | 0.05 |
Power accuracy | 0.01 | 0.01 | 0.01 |
Cabinet | |||
Battery cabinet | 966*855*2400mm | 966*855*2156mm | 966*855*2156mm |
Control cabinet | 2000*600*700mm | 2000*600*700mm | 2000*600*700mm |
PCS cabinet | 1400*825*2180mm | 1400*825*2180mm | 1400*825*2180mm |
Air conditioning | |||
Installation method | Embedded | Embedded | Embedded |
Cold power | 30KW | 30KW | 30KW |
Fire control | |||
Fire fighting medium | Heptafluoropropane | ||
Spray method | Pipeline (battery room) | ||
Fire detection tube (PCS room) | |||
Communication Interface | |||
Wireless | 2G,1 minute update | ||
Wired | Network, 5 seconds update | ||
System cycle life | >6000Cycle(25℃) | >6000Cycle(25℃) | >6000Cycle(25℃) |
Capacity availability | >80% | >80% | >80% |
Weight | <20T | <41T | <45T |
Structure size | 12.192m*2.438m*2.591m | 12.192m*2.438m*2.591m | 12.192m*2.438m*2.591m |
- Q: How is the capacity of the battery defined?
- 100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
- Q: Maintenance-free battery how to detect it?
- Do not always check the color of the electric eye for maintenance-free batteries. Green for the full power; black for the lack of electricity, need to be added to charge; gray or light yellow for the electrolyte is insufficient, because maintenance-free battery can not add liquid, should immediately replace the battery.
- Q: What are the advantages of maintenance-free batteries?
- The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
- Q: What is the meaning of the battery above 12v65Ah?
- 12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
- Q: How should the battery be well maintained?
- Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
- Q: 80ah how much battery storage capacity?
- The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
- Q: What kind of battery is divided into?
- Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
- Q: How does battery activation work?
- Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
- Q: Lead-acid battery how to maintain?
- When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.
Send your message to us
CFE Utility ESS 2580Kwh- 3440Kwh Battries in containers
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 watt
- Supply Capability:
- 10000 watt/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords