Ceiling Cassette Type Air Conditioner 36000BTU 3 Ton KFR-100QW
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 10 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Condition: | New | Brand Name: | CNBM | Place of Origin: | Jiangsu China (Mainland) |
Use: | Room | Power Source: | Electrical | Power Type: | AC |
Type: | Ceiling | Cooling/Heating: | Cooling/Heating | Certification: | CB,CE,EMC,RoHS |
Capacity (btu): | 36000 | COP: | 2.8 | EER: | 2.8 |
Power (W): | 3800 | Voltage (V): | 220 | Model Number: | KFR-100QW |
Pipe Size: | 3/8" + 5/8" | Condenser: | Pure Copper | Connecting Pipe: | Pure Copper |
Cable: | 4m | Compressor type: | Rotary | Loading Quantity: | 86sets (40HQ) |
Application Area: | 50-70m3 |
Packaging & Delivery
Packaging Detail: | Carton Box Packing |
Delivery Detail: | 30-45 days after receiving down payment |
Specifications
Ceiling Cassette air conditioner :
1, R22/R410a
2, 36000BTU 3ton;
3, Cooling only/Cooling& Heating ;
4, 220V 50HZ/60Hz
Ceiling Cassette Air Conditioner 36000BTU 3ton
1) Reliable quality---professional assembling and sufficient test, defective rate below 0.05%.
2) High quality compressors and parts with guarantee;.
3) Delivery: Within 45days after confirming the L/C or T/T swift copy.
4) Certificate--- CE, RHOS,MEPS, SAA, C-TICK, EMC, BV, SGS, ISO9001,SAA,CB, etc..
5) Compressor Brand: CHUNLAN, TOSHIBA, RECHI, HITACHI
6) 1% free parts of the total FOB amount.
7)OEM service.
- Q: Can I run my air conditioner 24/7?
- No, it is not recommended to run your air conditioner 24/7 as it can put excessive strain on the unit and result in higher energy consumption and potential damage. It is advisable to give the AC periodic rest periods to maintain its efficiency and longevity.
- Q: What is the principle of air conditioning
- Air conditioning refrigeration principle Air conditioner after electrify, refrigeration system of refrigerant in low pressure steam in the compressor and compression for high pressure steam back to the condenser. Axial flow fan at the same time in the outdoor air inhaled through the condenser, take away the refrigerant gives off heat, high pressure refrigerant vapor condenses into high pressure liquid. High pressure liquid after filter, throttle body spray into the evaporator, and the corresponding evaporation under low pressure, absorb the heat around. Tubular fan at the same time make the air entering the heat exchange between the finned evaporator, and the cooling after heat air to send to the interior. So indoor air circulation flow unceasingly, achieve the goal of lower temperature. Working principle of the heating Heat pump heating is the use of the compression of refrigeration system to heat the indoor air condenser. When he worked in the refrigeration, air conditioner, low pressure liquid refrigerant in the evaporator heat absorption and evaporation in high temperature and high pressure refrigerant exothermic condensed in the condenser. Heat pump heating is through electromagnetic directional, exchange the position of the suction exhaust pipe of the refrigeration system. Original refrigeration evaporator working indoor coil into the condenser when heating, such cooling system in absorption of heat to the indoor outdoor exothermic, achieve the purpose of heating.
- Q: The snow kind of what kind of air conditioning, they each have what effect
- The snow kind of classified as: 1, domestic now is the most commonly used freon R22. 2, new environmental protection refrigerant R410a refrigerant, everything, R407c, etc. The role of the snow kind of: Snow also called freon, freon will gas compressor for high temperature and high pressure liquid freon compression, and then sent to the condenser (seg) become normal temperature high pressure liquid freon after cooling, so the blow out outdoor hot air. And then to the capillary, into the evaporator (indoor machine), because the freon from capillary to evaporator space suddenly increases, pressure decreases, and liquid freon will China gas, into a gaseous cryogenic freon, to absorb a lot of heat, the evaporator will become cold, indoor machine of the fan will indoor air blows from the evaporator, so indoor machine out of the cold wind is blowing; Water vapor in the air is cooled after the evaporator will turn into water droplets, along the conduit flow, this is the reason why air conditioning will be out of the water. Then gaseous freon to go back to the compressor compression, continue to cycle.
- Q: Ordinary household air conditioner can heating?
- The higher the temperature is hot with anger, of course, and the wind speed and air volume Settings can also cause the temperature of the air
- Q: Air conditioning is vertical well, or hanging a good?
- Your place with the vertical air conditioning, my home is in hanging
- Q: Gree household air conditioners and household air conditioning of the same class which price is expensive, why?
- Gree than your point, because the gree air conditioning is the professional technology, awareness is strong, there is a word called, gree made good air conditioning.
- Q: Electric power is generally how many watts family air conditioning?
- Air conditioning general nominal horse, horse machine input power is 735 w, 1 2 horse machine input power 1500 w. Ark the input power generally is greater than 2000 w, can check the product nameplate, the choose and buy has a rated power input, is mainly used in household electric power calculation. See the model of air conditioner and can effect comparing, can know air conditioner work of electric power consumption.
- Q: Can an air conditioner help reduce humidity in a room?
- Yes, an air conditioner can help reduce humidity in a room. Air conditioners typically have a dehumidifying function that removes moisture from the air as it cools, helping to reduce humidity levels and create a more comfortable environment.
- Q: Air conditioning can not open 24 hours a day. Air conditioning will not bad ah
- Can open 24 hours, generally do not fail within short time. Normal use air conditioning, open 24 hours a day, there will be no special abnormal condition. Each style at the beginning of the air conditioning in the factory design will do at least 3 months of 24 hours a day long running test; Only after all belongs to mechanical components such as air conditioning compressor, blower motor, can have wear parts to each other, for a long time continuous open, may influence is brought by air conditioning compressor internal parts wear is aggravating, air conditioning actual life affected. 24 hours open air conditioning according to local air quality situation of every 15 ~ 20 days to check and clean a air conditioning indoor machine of return air filter, check whether there is any abnormal sound or vibration, on air conditioning separate-bodied air-conditioners running air conditioning indoor and outdoor machine connecting pipe with and without exception, air conditioning indoor machine in and out of the wind temperature difference value is normal.
- Q: What is the purpose of an air conditioner's compressor?
- The purpose of an air conditioner's compressor is to compress the refrigerant gas, which increases its temperature and pressure. This enables the refrigerant to absorb heat from the indoor environment and release it outside, resulting in the cooling effect produced by the air conditioner.
Send your message to us
Ceiling Cassette Type Air Conditioner 36000BTU 3 Ton KFR-100QW
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 10 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches