Specification of Round Diffuser
Round Diffuser
Supplying Air Diffusers
-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed
-Powder Coated RAL 9010/9016
Usage of Round Diffuser
The grille is suitable for ceilling sidewall, soffit or cill mounting and may be used for supply or extract applications.
Typical installations include offices, shops, hotels and most commercial or industrial buildings.
Available as standard in white polyester powder coat finish.
Other polyester powder coat finishes are also available as an option.
Size & Specification of Round Diffuser
round air diffusers | ||
circular ceiling diffuser | ||
round diffuser | ||
NECK SIZE(mm) | DESCRIPTION OF GOODS | |
Diameter | 100 | 1. Product name: round air diffuser |
Diameter | 125 | 2. Material: aluminum |
Diameter | 150 | 3. Powder coated: standard color, RAL 9010/9016 |
Diameter | 160 | 4. Damper with |
Diameter | 200 | 5. reduce the flow resistance and noise. |
Diameter | 250 | 6. The products are easy to install and clean. |
Diameter | 300 | 7.adapt to centrel air-conditioning systems. |
Diameter | 350 | 8. other size/colors available. |
Dimensions,colors,thickness, finished, disigns and other specification can be customized according to customers' request |
Paacking & Shipment
Packing:
PO shrink film bag for each pcs, ourter by export carton
PVC film + 4 plastic protection corners + carton box + closed wooden box optionally.
Shipping:
within 21 days after deposit
Products Show
FAQ:
1, What's size do u have for round type diffuser?
A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm
2, Do u still have other types ?
A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc
3, What's the most early delivery time?
A: Within 25 days for each 40'fcl
- Q: The air-conditioning compressor is stuck. Is there any way to repair it?
- In judging whether the compressor has a cylinder, it is necessary to make a comprehensive judgment according to the running state of the compressor, the working current, the temperature of the suction and exhaust, the temperature of the body, the normal capacity of the starting capacitor and so on
- Q: What is the function and control of the evaporator and condenser of the air conditioner?
- The condenser is like the boiling water on the stove
- Q: How to deal with the liquid hammer phenomenon of compressor
- The cause of liquid hammer is refrigerant or excessive lubrication, the liquid is too fast, the expansion valve (or valve) the regulation degree (opening) is too large, the heat load of evaporator (heat transfer) is not stable, large open type compressor suction valve open too fast (or unloading capacity too fast). System design and installation is unreasonable, abnormal shock may have caused the compressor
- Q: What is the cause of the overload of the air conditioning compressor?
- Dust on the outside condenser can be cleaned, and the heat insulation cotton wrapped on the compressor can be removed
- Q: What is the working principle of the compressor?
- A driven fluid machine that promotes low-pressure gas as a high-pressure gas; the heart of a refrigeration system. It is of low temperature and low pressure refrigerant gas suction pipe from the suction, through the operation of the motor drives the piston to compress it after high temperature and high pressure refrigerant gas discharge pipe to the exhaust, to provide power for the refrigeration cycle, so as to realize the compression and condensation (exothermic), expansion and evaporation (endothermic) refrigeration cycle
- Q: Refrigerators do not cool, compressors do not work, but very hot, what is the reason?
- Use ammeter to measure compressor starting and running current is normal (starting current is about 5~8 times of running current), such as current normal overload protector action, overload protector is out of order and should be replaced. Otherwise, the compressor is out of order.
- Q: What are the parts of an automobile air conditioner?
- The action of the compressor is to maintain the refrigerant circulating in the system, and improve the refrigerant gas pressure and temperature for gaseous refrigerant is condensed in the condenser into liquid and external heat expansion valve; the effect is to reduce the pressure of the liquid refrigerant through the throttling effect, convenient liquid, evaporation of the refrigerant into gas to absorb heat
- Q: How to repair air conditioning compressor?
- Check the compressor does not start trouble, such as the bottom of the capacitor drum, remove the capacitor, the bottom placed in the plane, such as standing instability, about rocking, then the compressor capacitor must be damaged, can be replaced directly
- Q: What is the Basic accessories for air conditioners?
- Motors, fans,air filters,Infrared humidifier and electrode boiler type humidifier
- Q: How many types of drive are there in an air conditioner compressor?
- The rotary compressor has fewer mechanical parts, and its motor is directly fixed on the shell. Compared with the traditional reciprocating compressor, the compressor is compact in size and light in weight. Its size and weight are almost half that of the latter, which makes it possible for the room air conditioner to be made more light.
Send your message to us
Aluminium Round air Diffuser Ceiling Use
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 pc
- Supply Capability:
- 999999 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches