Air Vent Diffuer with Steel Damper for Ceiling Use HVAC systerm
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 500000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification of Air Diffuser
Aluminium Round Diffuser
Supplying Air Diffusers
-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed
-Powder Coated RAL 9010/9016
Usage of Air Diffuser
The grille is suitable for ceilling sidewall, soffit or cill mounting and may be used for supply or extract applications.
Typical installations include offices, shops, hotels and most commercial or industrial buildings.
Available as standard in white polyester powder coat finish.
Other polyester powder coat finishes are also available as an option.
Specification of Air Diffuser
round air diffusers | ||
circular ceiling diffuser | ||
round diffuser | ||
NECK SIZE(mm) | DESCRIPTION OF GOODS | |
Diameter | 100 | 1. Product name: round air diffuser |
Diameter | 125 | 2. Material: aluminum |
Diameter | 150 | 3. Powder coated: standard color, RAL 9010/9016聽 |
Diameter | 160 | 4. Damper with |
Diameter | 200 | 5. reduce the flow resistance and noise. |
Diameter | 250 | 6. The products are easy to install and clean. |
Diameter | 300 | 7.聽 adapt to centrel air-conditioning systems. |
Diameter | 350 | 8. other size/colors available. |
Dimensions,colors,thickness, finished, disigns and other specification can be customized according to customers' request |
Products Show
Packing & Shipment
Packing:
PO shrink film bag for each pcs, ourter by export carton
PVC film + 4 plastic protection corners + carton box + closed wooden box optionally.
Shipping:
within 21 days after deposit
Packing:
PO shrink film bag for each pcs, ourter by export carton
PVC film + 4 plastic protection corners + carton box + closed wooden box optionally.
Shipping:
within 21 days after deposit
FAQ:
1, What's size do u have for round type diffuser?
A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm聽
2, Do u still have other types ?
A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc
3, What's the most early delivery time?
A: Within 25 days for each 40'fcl
- Q: What is the function of the air conditioning condenser?
- At this point, the outlet temperature of the condenser is about 35~45 degrees C, and the optimum temperature is below 40 degrees C. The refrigerant then enters the expansion valve or capillary to cool down
- Q: What is the purpose of a two-stage compression refrigeration cycle?
- Reduce the exhaust temperature of the compressor, increase the actual gas flow, improve the balance of the operation of the refrigerator
- Q: What is the working principle of the BOG compressor?
- General BOG compressor uses oil-free lubrication reciprocating compressor, the working principle is the same as the ordinary reciprocating compressor. The difference is that the inlet of the BOG compressor is low temperature gas, so the first stage cylinder block, piston and so on must be able to withstand low temperature, and also to prevent freezing
- Q: What is the cause of the overload of the air conditioning compressor?
- Dust on the outside condenser can be cleaned, and the heat insulation cotton wrapped on the compressor can be removed
- Q: What is the function of the refrigerator compressor?
- After the liquid Freon into the evaporator valve, due to the pressure from the compressor, immediately into steam, while absorbing the latent heat of vaporization to the air inside the refrigerator and food, resulting in internal cooling refrigerator
- Q: What is the working principle of the condenser?
- Single stage vapor compression refrigeration system, is composed of four basic components of the refrigeration compressor, a condenser, a throttling valve and an evaporator, between them with pipe connected to form a closed system, the refrigerant in the system continuously circulating flow, change, heat exchange with the outside world.
- Q: How to analyze air conditioning parts?
- The refrigerant operates in the sealed pipe between the parts and components, and carries, absorbs and releases heat so as to ensure the temperature of the indoor air can be adjusted. Ventilation system: fan and fan motors and ventilation ducts constitute the main part of the air conditioning ventilation system
- Q: What are the technical parameters of the compressor?
- The volume efficiency of a compressor is the ratio of the actual gas flow to the theoretical gas flow
- Q: What are the differences and characteristics of D M type V compressor?
- Both D and M compressors are mature compressor structures. If large displacement is required, the M model is recommended because the force of the crankshaft is more balanced, and the layout of the crankshaft is more reasonable, but the area is larger.
- Q: What is the Basic accessories for air conditioners?
- with six system,Air duct system, refrigeration system, humidifying system, electric heating system, power distribution system and control protection system
Send your message to us
Air Vent Diffuer with Steel Damper for Ceiling Use HVAC systerm
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 500000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords