ISG Vertical Centrifugal WAter Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
ISG series vertical pipeline cooling water centrifugal pump
Performance Parameters :
a) Caliber: DN40-DN125mm
b) Flow: 2.8-100m3/hr
c) Head:3-38 m
d) Rotate speed: 1400,1450r/min
e) Viscosity: ≤100mm2/s
g) Motor power:0.12-30 KW
h) Working temperature: ≤100°C
ISG series single stage single suction pipeline centrifugal pump is designed on the base of
domestic execellent water power model and the performance parameter of IS series cen-
trifugal pump.
ISG Series centrifugal pumps are designed for such as hot water pump and corrosion resi-
stance pump and oil pump for the different temperatures and liquids. The pump has good
performance of reliable operation and high effeciency and little noise etc.
1,Compact structure,horizontal structure ,beautiful appearance and less area of occupied land,
which comparing with the ordinary ones is reduced by 30%;
2,Stable running ,low noise,high concentricity of assembly.By the straight joint between motor
and the pump.the moddle structure is made simplified ,thus enhancing the running stability ,
making the impeller of a good balance of moving -resting ,resulting in no vibration during run-
ning and improving the environment of usage .
3, No leakage .a mechanical seal of antisepticcaarbide alloy is ued for the shaft sealing so as to
let rid of the serious leakage of the fillings of centrifugal pumps and ensure the operating place
clean and neat ,
4,Convenient service .
1.ISG series vertical pipeline centrifugal pump is used to transport the water and other liquid
similar to the water in physical and chemical characteristic. It is widely used for the drainage
in industry and city, booster and water supply for high-building, irrigation in garden, booster
in fire fighting, transporting from along distance, water circulation in circultion system etc.
Working Temperature<80oC.
2. IRG series vertical hot water pump is suitable in metallurgy, chemical industry, textile, timber
processing, paper making and booster and circulating for high temperature and hot water in
hotel.
Working temperature <240C.
3. IHG series vertical pipeline chemical pump transports the liquid which is corrosive an without
solidgrain and similar to water in viscosity. It is suitable in petroleum, chemical industry,metal-
lurgy, electric power, paper making, food an pharmacy and synthetic fibre etc.
4. IHG series stainless steel chemicalcentrifugal pump with explosion-proof is suitable to trans-
port the flammable chemical liquid.
- Q: How can the submersible pump level meter be connected?
- The company actively introduce international advanced production equipment and production technology, with its strong technical force, perfect equipment conditions and rich manufacturing practice, constantly development and improvement of pump products, according to the needs of users of innovative products, stable performance, excellent quality, many products export part countries and regions
- Q: What are the general water pump failure, how to repair?
- (2) in contact with the water pump inlet of the horizontal application of reverse flow direction, fell more than 0.5% slope, connect one end of the highest import pumps, do not completely level. If the upward tilt, the intake pipe will retain air, reducing the water pipes and pumps in the vacuum, water absorption.
- Q: Troubleshooting of diaphragm pump
- The ratio of flow to water weight at a specific weight of --68F. 68F water has a specific gravity of 1Static suction head - the vertical distance from the liquid level to the central line of the pump. The pump shall be above the level of the liquid.Vapor pressure the pressure of all the steam on the free surface of the liquid. In any pump operating system, the operating pressure shall not be lower than the vapor pressure, otherwise the steam will be partially or completely cut off into the pump fluid. Viscosity - because of the presence of friction in the fluid, the property of viscosity gives the fluid resistance to flow.Water hammer action -Water hammer is a sudden power failure, or in the valve closed too fast, due to pressure, flow of inertia, produce water shock waves, like hammer hammer, so called water hammer. The force produced by the flow of water shock waves can sometimes be very large, thereby damaging the valves and pumps. Water hammer effect refers to the inside of the water pipe, the pipe wall is smooth, flow freely. When the opening of the valve suddenly closes, the flow of water to the valve and the tube wall, mainly the valve, will produce a pressure. As the pipe wall is smooth, the subsequent water flow in the role of inertia, the fastest reach the maximum and damage, which is the water conservancy "water hammer effect", that is, "positive water hammer.". This factor should be taken into consideration in the construction of water conservancy pipelines. On the contrary, the valve closed in a sudden opening, it will produce water hammer, called negative water hammer, but also a certain destructive power, but not the former big.. Causes and treatment methods of common failures of diaphragm pumps:
- Q: What does "anti pump" mean in pump operation?
- The pump again is the pump, the theory is the plugging problem can be solved, but if you are against the pump after pump has been plugging serious, and pump has been unable to solve the plugging problem, finally the worst solution is a split pipe, if the situation under enormous pressure will only exacerbate the plugging
- Q: What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
- When the pump is working, the liquid at the inlet of the impeller, due to a certain vacuum pressure will produce steam, the vaporization of the bubble in liquid particles under the impact of movement, the impeller and other metal surface erosion, thereby damaging the impeller and other metal
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- 15MPa. 20MPa means that if you enter the 20MPa, the variable mechanism will work, and the flow at this time automatically matches the load. 20MPa used to supply the fuel by maximum displacement.
- Q: How many kilograms of water pump are there in the automatic washing machine on the market?
- Suitable for supporting high pressure sprayer, portable car washer. Water pump with overflow circuit. And comes with pressure switch, overflow switch double insurance
- Q: Water pump does not produce water, what are the reasons?
- The reason why centrifugal pump does not produce water:1. pump inlet or sink, water tank water shortage.2. water pump pipe blocked or valve not open.
- Q: The working principle of magnetic pump
- Magnetic pumpBy the pump magnetic pump, magnetic actuators, motors of three parts. The key components of magnetic actuator by the external magnetic rotor sleeve, inner magnetic rotor and non magnetic components. When the motor drives the outer magnetic rotor, the magnetic field can penetrate the air gap and non-magnetic material, driven by the inner magnetic rotor is connected with the impeller for synchronization the rotation, to achieve non-contact power transmission, the dynamic seal into static seal. As the shaft, the rotor is within a magnetic pump, isolated sets of completely closed to completely solve the problem of "run, run, drip, leak, remove the oil refining chemical industry flammable, explosive, toxic and harmful media through the pump seal leakage security risks, effectively ensure the health and safety of workers.
- Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
- Related concepts of hydraulic motorsFlow theoretical volume refers to the volume of oil inhaled in unit time without leakage.