• Gel Battery 12V-150AH System 1
Gel Battery 12V-150AH

Gel Battery 12V-150AH

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
10 Pieces pc
Supply Capability:
10000 Pieces per Week pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Features:

 

 1. Completely sealed and water-free maintenance, no acid gas and environmental friendly.

 2. It has adopted colloid electrolyte technology, avoiding density stratification problem of acid solution and eliminating plate corrosion and passivation caused by density stratification.

 3. It has a long float charge life. The designed life of 12V series battery can reach up to 6 to 8 years (environment temperature from 20°C to 25°C).

 4. Applied with German Gel formula, grid alloy and plate formula, the battery is performed very well in cycling and recovery from deep discharge, especially in rainy days.

 5. More suitable for using in harsh condition than AGM battery as the rich electrolyte inside of the GEL battery makes it working stable in high temperature or over charge.

 6. Good performance in cold environment and the battery capacity decreases little when using in low temperature.

 7. Little self discharge because of the super-pure material and the low density of the electrolyte, it can be stored over 6 months.

Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Q:3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, filament, cold resistance and simultaneous startup factor, it is better to choose the 400VA transformer
Q:The transformer zero line has broken, has the result to the household illumination circuit?
When the zero line break line is not broken, the voltage drift of the point voltage leads to the rise of the 220V branch voltage and the reduction of the 220V branch voltage
Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
Q:What type of low voltage transformer should be adopted for safety lighting power supply?
We have produced many low voltage lighting transformers, such as outdoor waterproof, high-power stage lighting, as well as indoor small power transformers, customer response, but also good! For example, Guangzhou Color Art Lighting Co., Ltd., before them, our reputation is good!
Q:How many A leakage protection switches are used in 5000VA lighting transformers?
It is widely used in the electronic industry or industrial and mining enterprises, in the machine tool and the mechanical equipment, the control power of the general electric circuit, the use of the power supply of the safety lighting indicator lamp.
Q:Why is elevator lighting transformer installed?
9.4.5 well distribution shall comply with the following requirements:1 the elevator hoistway shall be dedicated to the elevator, and no equipment, cables and other devices related to the lift shall be installed in the hoistway.2 the well shall be provided with illumination, and the illumination shall not be less than 501x, and shall comply with the following requirements:
Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
Our experienced R&D team enables us to build customized product lines for our clients. Besides OEM and ODM services, we also provide complete after-sales and professional technical support for any customer. We have gained wide popularity and recognition at home and abroad.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2000
Annual Output Value US$5 Million - US$10 Million
Main Markets 10.00% North America
10.00% South America
10.00% Southeast Asia
10.00% Mid East
10.00% Eastern Asia
10.00% Africa
5.00% Eastern Europe
5.00% Western Europe
5.00% Central America
5.00% Northern Europe
5.00% Oceania
5.00% Southern Europe
5.00% South Asia
5.00% Domestic Market
Company Certifications ISO 9001:2000;ISO 14001:2004

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Guangzhou
Export Percentage 51% - 60%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords