Online UPS Power Supply 1KVA, 2KVA,3KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Units pc
- Supply Capability:
- 5000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application:
T Series 1KVA~3KVA High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Key Features:
LED Indicators display Detailed Real-Time UPS Status and parameters.
Set Output Voltage, Frequency parameter and bypass function on the display.
Advanced MCU microprocessor control technology, ensure long life reliability.
Wide input voltage range, Zero transfer time
Excellent Protection against over voltage, over load, over current, over charge and so on.
Input L and N lines reverse wiring detection, Auto start when AC back.
DC start function, Input PFC revise function.
Humanization bypass output, can be adjustable.
Smart RS232 communication with monitoring software
Intelligent slot available for AS-400 Dry contact and SNMP card Remote control
Available to work with generators.
Lightning, surge, short circuit, Network/fax/modem surge protection
Basic tech datasheet
UPS Model | EX1K | T1K | EX2K | T2K | EX3K | T3K | |
Capacity | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | ||||
Input | Voltage | (115~300) VAC | |||||
Frequency | 46~54Hz/56~64Hz (Adjustable via LCD panel) | ||||||
Output | Voltage | 220/230/240 (1±1%) VAC (Adjustable via LCD panel) | |||||
Frequency | 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz (1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%) | ||||||
Output Wave Form | Sine Wave | ||||||
Back-up Time | Full Load | ≥5′ | ≥9′ |
| ≥5′ |
| |
Half Load | ≥14′ | ≥21′ | ≥15′ | ||||
Battery Nominal DC Voltage | 36VDC | 96VDC | |||||
Transfer Time | 0ms | ||||||
Overload Capacity | 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms | ||||||
Communications | RS-232+Intelligent Slot | ||||||
Environment | Temperature | 0C~40C | |||||
Humidity | 15%~90% | ||||||
Dimensions (W*D*H)mm | 400*145*220 | 460*192*348 | 460*392*348 |
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
- Q:The transformer zero line has broken, has the result to the household illumination circuit?
- When the zero line break line is not broken, the voltage drift of the point voltage leads to the rise of the 220V branch voltage and the reduction of the 220V branch voltage
- Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer load end and the power supply terminal is not connected, is safe, and autotransformer primary winding of a share, it is directly connected with the power supply end of the power, not safety.
- Q:Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q:How many A leakage protection switches are used in 5000VA lighting transformers?
- Line lighting transformer is suitable for AC circuit of 50~60 (Hz). It is widely used in electronic industry or industrial and mining enterprises, mechanical equipment, general circuit control power supply, safety lighting and indicator light power supply.
- Q:Can the 500 volt lighting transformer be changed into an electric welder?
- The structure of the electric welding machine is different from that of the transformer, and the magnetic gap of the iron core can be adjusted so that the welding current can be changed. In addition, the output voltage of the welder is also soft
- Q:What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q:What's the function of the lighting transformer?
- In addition, can be rated power supply voltage of not more than 1000V AC circuit, as a machine tool and mechanical equipment control power, work lighting and signal light power supply, can also be used as a small power supply!
- Q:Why can't autotransformer be used as transformer for safety lighting?
- When a fault occurs, leakage of electric leakage occurs, and the original coil is transmitted to the residents at high voltage, causing disastrous effects on the human body and property!
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS Power Supply 1KVA, 2KVA,3KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Units pc
- Supply Capability:
- 5000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords