Dual Plate Check Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 80000 Tons Per Year pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery of Dual Plate Check Valve
Packaging Details: Standard Plywood Box
Delivery Detail: within 35days
Specifications of Cast Iron Check Valve Wafer Type
Certificate:CE,API,ISO9000,ISO14001,KS,GOST
Size from 2" to 48"
Face to Face:According to ISO Standard
Flange:Sccording to ANSI/BS/DIN/JIS
Nominal Pressure:PN10/PN16,125LB/150LB
Valve Body:Cast Iron
Disc:Ductile Iron,Stainless Steel,Brass,Bronze Seat:NBR,EPDM Stem:Stainless Steel
Technical Data of Cast Iron Check Valve Wafer Type
Size: DN10-DN3000
Power station valve, double-eccentric semi-ball valve, satefy valve, gate valve, check valve, no return valve, butterfly valve, etc.
Nominal Pressure: PN10/PN16 Test Pressure:1.0Mpa-50.0Mpa Sealing: PN11/PN17.6 Shell: PN15/PN24
Working Temperature: -15~ -250
- Q:Check valve note BC/PISTON: SPR-L what does that mean?
- BC==Bolted Cover/ bolted bonnetPISTON== lifting typeSPR-L==Spring-loaded/ is loaded with springsTogether, it is: a spring-loaded check valve. Bolted bonnet (this is common)
- Q:My house is public flue, a total of six floor I live five floors, with the side suction hood, hood in the windy outside started as soon as the check valve pops ring from occupancy, have what way?
- Please take the pipe at the hood of the range hood for 15 cm or more, and then blow the wind. Note that the installation of fixed, do not affect the valve sag.
- Q:Furnace blower outlet check valve what
- One can be installed to prevent the backflow of high temperature gas in the boiler
- Q:The role of the clip lift check valve
- It only allows the medium to flow in one direction and prevent the flow in the opposite direction. Usually the valve is automatically work, fluid pressure flow in one direction, the valve open; the opposite direction of fluid flow by gravity, fluid pressure and valve closing effect on the valve seat, thereby cutting off flow. Check valves are generally applicable to clean media and are not suitable for media containing solids and viscosity.
- Q:Is the hdf41x 1.6Mpa a check valve?
- Backflow prevention device according to tap water supply equipment, especially drinking water pipe back to serious pollution, and effectively prevent the pollution device under the condition of a strictly limited hydraulic control assembly pipeline water only one-way flow of development, its function is to prevent backflow pipeline media in any condition, in order to avoid the purpose of backflow pollution.
- Q:What is the function of the check valve installed in the water meter before entering the residential water?
- The check valve installed before the water meter is convenient for the maintenance, maintenance and management of the user's water.
- Q:How can the fast closing noise check valve prevent water hammer?
- Biaoguan valve that once the pump stopped, check valve spool in the spring or other auxiliary device for double end under the action of force balance in advance to the closed position, can greatly reduce the amount of water and initial water reflux falling height, water hammer force is calculated by gravity superposition, to reduce the amount of water is equal to the reduced gravity, but fell short height reduces the inertia time is relatively reduced speed, and can prevent the formation of destructive or reduce water hammer water hammer.
- Q:What's the difference between the H76H model and the H76J check valve?
- This is a standard set, the landlord can see the standard: JB/T 308-2004H = check valve7 = clip type (connection mode)6 = double plate (structural form)After hundreds of H = 13Cr, sealing surface, J = rubber sealing surface
- Q:Is it necessary to install a check valve in front of the water meter? Does the water company have a definite requirement?
- UnnecessaryWater meter before the loss of running water, their own things, do not need customers to bearAfter the water meter is equipped with a small gate valve or a ball valve, it is convenient to repair and replace
- Q:Does FOTILE hood have check valve?
- Therefore, it is necessary to install a check valve at the flue port.
1. Manufacturer Overview |
|
---|---|
Location | Jiangsu,China |
Year Established | 2001 |
Annual Output Value | US$10 Million - US$50 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | English |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered |
Product Price Range | High and/or Average |
Send your message to us
Dual Plate Check Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 80000 Tons Per Year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords