• Cummins Genset Diesel Generator , 30kva to 600kva Power Generator System 1
  • Cummins Genset Diesel Generator , 30kva to 600kva Power Generator System 2
Cummins Genset Diesel Generator , 30kva to 600kva Power Generator

Cummins Genset Diesel Generator , 30kva to 600kva Power Generator

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Cummins Diesel Engine:4BTA3.9-G2,6BT5.9-G2,NTAA855-G7A 

2. AC alternator: Leroy Somer, Stamford, Marathon

3. 10-hour operation base tank

4. CE Certificate

 

 

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G1

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190

 

 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

 

Q:What is the difference between a step motor and an ordinary motor
A dc motor usually requires only two lines, and the step motor requires 4-5 jumper lines The speed of dc motor is higher, and the speed of stepping motor is slower The Angle of rotation of the dc motor is difficult to calculate accu
Q:The advantage of the pole motor relative to the ordinary motor
She points to the pole machine: Reasonable structure design flexible lead direction, the bonnet motor junction box can rotate and install itself Excellent protective grade of low noise, low vibration and high performance
Q:Is the washing machine an ordinary motor or DD converter?
All the shares, after sales, panasonic, didn't come together, But it's hard to say, everything is bad, The individual advised you to buy a cheaper one, I want to tell you a little bit about it. The wave wheel, the drawback, the super waste water, wear the clothes, can't wash the big pieces. Advantages, shorter washing time, better cleaning ratio, 2, drum, shortcomings, can't use washing powder, was leaking bubble in the rinse impurities, washing time, rinse than low, advantages, it does not hurt the clothes, super save water, can wash large appropriately, but clothing thickness distribution well, the price is a relatively expensive To sum up, the house is rich in good clothes to buy the roller, the economic popular clothing is not too high-grade or buy the wave wheel, hehe, Also throw in a word, don't buy too good, life is all about, cheap cheap bad repair, repair threw a don't worry about too expensive, ha ha, the brand is just a symbol,
Q:The difference between brushless dc motor and plain dc motor, where is its advantage
If the simplest commutation circuit is taken, there is no difference between controlling and dc motors. The difference is that there is no such thing as a brush In other words, replace the commutation with electric electronics Other advantages are due to the absence of brushes
Q:In the case of ac motor, the voltage will be higher or lower in constant voltage, which will affect the motor.
Induction ac motor, power frequency rise will increase the speed, the rising frequency motor inductance, the current will be reduced, current motor temperature rise will decline. When the frequency of the power supply decreases, the motor speed decreases, the electric current is raised by the decrease of the motor's inductance, and the temperature rises.
Q:How do you differentiate the converter motor from the general motors?
Variable frequency motor and the common one of the biggest difference is the fan cooling way, general motors was the cold, the fan on the motor shaft, changes with the rotational speed of the motor, so the ordinary motor at low frequency heat dissipation is not ideal. Frequency conversion motor cooling fan is behind the motor equipped with a cooling fan, need an external power, the fan will not be affected by the speed of the motor, is a strong refrigeration.
Q:The difference between PWM and general motors
PWM motor is frequency conversion motor, that is, the inverter output waveform is not filtering after PWM wave, ordinary motor generally as a standard, usually sinusoidal waveform, if use frequency converter drive, also need to add after the inverter output filter circuit, or general motors can not stand, fever is serious, but also is frequency conversion motor PWM motor is ok.
Q:What is the difference between a general motor and a high-speed motor?
Ordinary ac motor is restricted by the maximum synchronous speed, which can not reach high speed, dc motor (especially brushless motor) can achieve higher speed. The static balance and dynamic balance of high speed motor are high.
Q:What is the difference between a general motor and a converter machine?
By the way, with the development of the manufacture of electric motors, there is no ordinary motor and FM motor. I'm talking about the real manufacturer of motors. The index of the mouse cage ac motor is basically 0 -- 50Hz -- 100Hz. This is the FM motor. Now domestic electrical manufacturers, too, dominate this category. Like Siemens's domestic electric motor manufacturing plant, ABB's domestic electric motor manufacturing plant, its products are fully tuned electric motors.
Q:What is the difference between explosion-proof motor and ordinary motor
Both sides (1) the motor end cover bolts grooves dark and slot 5 times deeper than the ordinary motor (still need to add asbestos washer as required), mainly for internal winding burned one thousand, gap with the spark will not up to the outside. (2) of the motor terminal box added gasket sealing with excellent structure, internal pinout of windings is sealed lead to the terminal, and in order to reduce the generated sparks link only commonly lead to three points (normal is six, connection piece). (3) terminal block access of the external power source, is to extend the ten centimetres, movable connection, both ends with airtight fire tube thread interface, can join explosion-proof motor reliably threading pipe, so that the motor and the input power cord meet all closed fire prevention requirements

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords