• Wholesale 5 Lines Laser Level Series QQ-SL06 System 1
  • Wholesale 5 Lines Laser Level Series QQ-SL06 System 2
  • Wholesale 5 Lines Laser Level Series QQ-SL06 System 3
  • Wholesale 5 Lines Laser Level Series QQ-SL06 System 4
Wholesale 5 Lines Laser Level Series QQ-SL06

Wholesale 5 Lines Laser Level Series QQ-SL06

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT or LC
Min Order Qty:
500 set
Supply Capability:
40000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Model Number: QQ-SL06
Emit:  4V1H
Length of the ray: Vertical & horizontal:635nm following points:650nm
Working distance:   Radius 10m
Leveling of automatic numerical values: ±3°
Angel of the launch: ≥ 110°
Accuracy of the level: ±1mm/7m
Vertical accuracy:   ±1mm/7m
Accuracy of the rectangular: 90°± 0.025°(±1mm/3m)
Accuracy of the following points: ±1mm/1.5m
Accuracy of the orthogonal: ±1mm/3m
Width of the line: 2.5mm/7m
Work environment:  Indoor/outdoor
Power supply: DC4.5V (3x1.5AA)
Working time:  ≈8hours
Working temperature: -10℃-+45℃

Q: In the decoration, why use laser level instrument out of the horizontal line, hit on the wall, there will be a slight jitter? The farther away, the greater the jitter
Is mainly due to the level of internal, internal energy and good magnetic distance is too high, resulting in a level is difficult to stabilize, another factor is the construction, such as vibration, electric hammer, saw, hammer in the construction, will lead to, and level is not good with this kind of problem. Zhejiang Yuli company, Ben Simailong, Jiangsu Deli, laisai, Leica
Q: When the laser level is opened horizontally, it does not move on one line when it moves around. How can it be corrected?
The laser level adjustment in the horizontal center position, must take the center point adjustment in the center position, the more accurate and better. Don't think that we didn't ring eccentric alarm at certain position in the center, in fact is not necessarily is the center, but at a distance shorter than not more than 10 meters outside the basic can be a one-time success. The largest error is not more than 3 mm. When the flat side of the distance is beyond the scope of the provisions of the level; if the adjustment center at this time is not accurate so you need to first level line type as the base line to end then extended or moving position and the direction of the words: it is certainly to the connection is not at the same level error is large, so the level of the line side must not!
Q: What are the common problems with infrared laser levels? How should I solve it?
Probably because the machine is not flat, put the machine on the flat ground, it should not be. If it will still be, and there is a problem inside the machine, it is recommended to send back to the factory maintenance.
Q: What's the difference between 2 wire, 3 wire, 5 wire laser infrared level?
General decoration master will buy a step in place, 5 lines, the relevant product maintenance and operation instructions, welcome to receive in; Zhengzhou light laser level is just fine
Q: What's the use of an automatic laser level?
A vertical line horizontal angle line, multi point used for interior decoration, outdoor light strong out of sight line
Q: Laser level sDB1, four threads are all broken, I do not know which welding!
Red is the power cord, VCC, black are H, V1, V2 and OUT, red do not answer the wrong line, and other connected wrong, it does not matter
Q: The role of the bottom magnet of the laser level
Specializing in the sale of precision measuring instruments - Wuxi Rongsheng
Q: How to use laser level?
When measuring, the working surface of the level instrument is close to the tested surface, and the reading can be carried out until the bubble is completely stationary.The graduation of the level meter is based on the slope value of one meter long, and the actual tilt, if measured at L, can be calculated by the lower type:Actual slope value = division value *L* deviation grid numberIn order to avoid the measurement error caused by the zero position of the level instrument, the zero level of the level instrument must be checked or adjusted before use.Zero calibration and adjustment method of level instrument:Place the level gauge on a flat, substantially flat plate (or machine tool guide), until the bubble is stable, at one end, such as the left end, and zero. Then turn the level of 180 degrees, still placed in the original position of the plate, to be stable after the bubble, still in the original one (left) readings A, the level of zero error is two points A grid. If the zero error exceeds the permissible range, then adjust the level zero adjusting mechanism (adjustment screw or nut, the error is reduced to zero within the allowable value. The nut shall not be turned freely for the screws which are not specified. Adjust the level of working surface and the plate must be torn wipe clean. The adjusting screw or nut must be tight
Q: Laser level instrument broken line, how to repair?
This kind of instrument needs to be corrected on a special station. Even the general circuit problems need to be corrected after the maintenance, not to mention the laser tube is burned and needs to be replaced.
Q: How can the laser level adjust the height of the horizontal line?
You can fix the level on the three stand and adjust the height of the horizontal line by adjusting the height of the three leg.Laser level meter operation mode:When measuring, the working surface of the level instrument is close to the tested surface, and the reading can be carried out until the bubble is completely stationary.The graduation of the level is based on the slope value of one meter as long as the actual tilt of the length of L is calculated by the following: the actual slope = the value of the division *L*, the number of deviationsIn order to avoid the measurement error caused by the zero position of the level instrument, the zero level of the level instrument must be checked or adjusted before use.Level zero calibration method: the horizontal instrument is placed on the base of the stable and approximately horizontal plate (or machine tool guide rail). When the bubble is stable, the end is read at the end, such as the left end, and zero. Then turn the level of 180 degrees, still placed in the original position of the plate, to be stable after the bubble, still in the original one (left) readings A, the level of zero error is two points A grid. If the zero error exceeds the permissible range, then adjust the level zero adjusting mechanism (adjustment screw or nut, the error is reduced to zero within the allowable value. The nut shall not be turned freely for the screws which are not specified.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches