• VRLA Battery MP Series Battery  6-GFM-150FB System 1
  • VRLA Battery MP Series Battery  6-GFM-150FB System 2
  • VRLA Battery MP Series Battery  6-GFM-150FB System 3
  • VRLA Battery MP Series Battery  6-GFM-150FB System 4
  • VRLA Battery MP Series Battery  6-GFM-150FB System 5
VRLA Battery MP Series Battery  6-GFM-150FB

VRLA Battery MP Series Battery 6-GFM-150FB

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
500000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


 VRLA Battery MP Series Introduction

The MP range VRLA batteries is designed with front terminal structure. The perfect design ensures MP series battery the high reliability and makes the installation quite simple and safe when placed on a standard relay rack tray or in a closed cabinet.

MP range VRLA battery is designed with high energy density and suitable for 19", 23" rack or cabinet, and also offers options of top connection and side of monoblocs connection.Mp range battery can be equipped with central gas collection system according to the requirement of customer.

The MP batteries are ensured the quality with NARADA's QA system according to the ISO9001 standard.

VRLA Battery MP Series Battery  6-GFM-150FB


VRLA Battery MP Series Battery  6-GFM-150FB

VRLA Battery MP Series Battery  6-GFM-150FB

VRLA Battery MP Series Technical Feature:

  • AGM technology applied in MP range batteries.

  • Front-access terminal connections for fast and easy installation and maintenance

  • Suitable for 19", 23" rack or cabinet

  • Excellent special lead-tin-calcium formula alloy for Grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full float  service at 25oC(77oF)

 

Type:

  6-GFM-150FB

Voltage:

  12V

Nominal Capacity:

  150Ah(C10)  150Ah(10 hours rate:)

Length:

  550mm

Width:

  110mm

Height:

  285mm

Height  with termial:

  285mm

Weight:

  44Kg

VRLA Battery MP Series Compliant Standards :

  • IEC60896-21/22

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobatt guide

  • UL

  • Manufactured under system ISO9001(TUV)

VRLA Battery MP Series Installation Compliant with:

  • EN 50272-2 or local equivalents

VRLA Battery MP Series Main Application:

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Switchgear / utility

  • Other applications to provide integrated stored energy system

VRLA Battery MP Series Products Characteristics:

  • Recommended float charge voltage for 12V battery:

  • 2.25Vpc at 25oC(77oF)

  • Self discharge rate:< 2% per month at 25oC(77oF)

  • Shelf life: 6 six months at 25oC(77oF)

  • Valve regulated system, no water addition needed.

FAQ


What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

How can I evaluate the health and charge state of a battery?

Routine battery examinations divulge irregularities in the charging system as well as in the batteries. The principle method is to examine the electrochemistry of the battery through hydrometric electrolyte inspection. As previously discussed, this important examination cannot be accomplished with sealed absorption or gel batteries. Voltage readings alone require experience to interpret. Hydrometric readings will uncover early warnings of overcharging or overdischarging before batteries are damaged. The state-of-charge and reliability of a lead acid battery can best be determined by the specific gravity of the electrolyte measured directly with a common bulb-type hydrometer with a glass float. We do not recommend the ball float type hydrometer. Specific gravity is a unit of measurement for determining the sulfuric acid content of the electrolyte. The recommended fully charged specific gravity of marine batteries is 1.255 to 1.265 taken at 80ĄăC More than .025 spread in readings between fully charged cells indicates that the battery may need an equalization charge. If this condition persists, the cell is failing and the battery should be replaced. Since water has a value of 1.000, electrolyte with a specific gravity of 1.260 means it is 1.260 times heavier than pure water while pure concentrated sulfuric acid has a specific gravity of 1.835.


 

Q: What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q: What are the technical parameters of the battery?
The main performance parameters of the battery are the following: model; voltage; battery capacity; battery type, such as lead-acid batteries, alkaline batteries, lithium batteries, solar cells, fuel cells.
Q: What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q: Maintenance-free battery how to detect it?
When using a maintenance-free battery, it is easy to think that maintenance-free is the idea that no maintenance is required. Maintenance-free Although maintenance costs and times can be reduced, but for the appearance of the clean-up is essential, so that "maintenance-free" more point to the battery inside.
Q: What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q: 80ah how much battery storage capacity?
The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
Q: The role of the battery?
Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.
Q: How does the battery increase the voltage?
You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
Q: What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q: Lead-acid battery how to maintain?
Along the battery cover on the exhaust hole, open the battery cover plate, some of the battery cover is APS adhesive, and some batteries are buckle connection, pay attention to open the cover when the cover plate The At this time you can see the six exhaust raft rubber cap.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches