• Solar Aviation Obstruction Light System 1
Solar Aviation Obstruction Light

Solar Aviation Obstruction Light

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
3000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Solar aviation obstruction light 

Solar obstruction light

low intensity light

 

Specifications of Solar Aviation Obstruction Light

Description

Parameter

International standard

ICAO(Aerodromes Annex 14)low intensity light TYPE-A

Light source

LED

Intensity

>10cd (flashing) 

Flash settings

60time/min(other type can be customized)

Horizontal divergence

360°

Vertical divergence

≥10°

LED lifetime

100,000 hrs 

On/off level

70/100 Lux 

Battery capacity

3.6V/8AH (maintenance-free) NIMH 

Solar Battery power consumption

1.8W   

Ambient temperature

-30°C~+70°C

IP Protection

IP65  

Continuous operation in rainy time

20 days

Mounting

177mm (Dr) * 238mm(H) 

Visible distance 

>3.6Km (atmospheric transparency=0.85) 

Weight

2.3Kg 

 

Functions & Features

Based on LED technology

Aviation red type

Base material-- Die casting aluminum LM6

Lamp housing -- Polycarbonate with UV resistance

Bird spike

Built-in photocell

Steel wire is used to connect base to housing against falling in operation

Built in NIMH battery, ease for replacement

No RF-radiations, EMC compliant

Shockproof and corrosion resistance

Extremely Reliable -- Major maintenance cost saving

Very low power consumption -- Low energy cost  Mount the solar light in the most suitable place such as under direct sunlight, to ensure its continuous operation.

Screw the lamp on the G3/4'' threaded pipe, which should be fixed on a smooth surface with enough mechanical strength (see mounting drawing).

When first operation, if the light does not light up in dark places, please put the light under direct sunlight for approx. 12 hrs.

Please keep the light in a very dry place, such as places with low humidity if do not use the light for a long time. Put the light under direct sunlight for three days every 40 days, to ensure the battery capacity.

Built in NIMH battery, after being used 450 times (15 months), the battery capacity is approx. 80% of previous capacities, at this moment, please replace the battery in time.

Q: What's wrong with the emergency lights?
it means that you have a problem with the battery.
Q: Is the wall wiring for fire emergency lights and safety exit signs piping or iron pipes?
the fire separation zone must install fire doors must be equipped with double automatic system, with the fire regulations.
Q: What's the role of the fire emergency light?
When a fire occurs, the power supply system of the fire scene is being cut off, at the scene of the fire will be dark, the scene of the fire personnel cannot quickly find the exit, which threatened the lives and safety.
Q: Does the kindergarten classroom install fire emergency lights?
still need to work two, the fire control room, fire pump room, generator room
Q: How to install emergency light?
() alternate lighting is the illumination that is set in order to continue (or continue to work) when normal lighting fails.
Q: How do you turn off the emergency light?
In addition, a test button is provided on the emergency lamp housing to control the lighting or extinguishing of the emergency lamp when the emergency lamp is not connected with the lighting power supply
Q: Where should fire emergency lights be installed?
Three, auditorium, building area of more than 400m2 of the exhibition hall, business hall, multi-function hall and restaurant, building area of more than 200m2 studio;
Q: How much is the distance between fire emergency lights?
10 meters or so, the maximum can not exceed 20 meters
Q: How should the fire emergency light switch be connected?
Emergency lighting has two kinds: 1, general lighting +UPS or EPS power supply, the light run line is connected with a power supply of ok2,
Q: How can the emergency light be changed into common light?.
The process is like this, switch to the A terminal, plug in the listed 220V, charge the battery, if the electricity is stopped, the LED light is on.
Every year, many accidents occur all over the world because of safety troubles. Injury and wrongful death expectancy in industry working environment is far higher than after-working environmen。Our engineers go to all of above work sites to develop more reliable industry warning & communication products. we believe imaginative work can change the world. We wish that our company could be an internationally competitive firm. Through lasting, hard working, we expect a prosperous future!

1. Manufacturer Overview

Location Shanghai,China (Mainland)
Year Established 2009
Annual Output Value US$50 Million - US$100 Million
Main Markets South America 3%
Southeast Asia 6%
Africa 8%
Mid East 2%
Western Europe 80%
Company Certifications ICAO Certification; CE Certificate; CE Certificate; CE Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage 31% - 40%
No.of Employees in Trade Department
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 5,000-10,000 square meters
No. of Production Lines Above 10
Contract Manufacturing Design Service Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches