AC film capacitors for general purpose applications (e.g. AC filters with harmonic frequencies exceeding 60 Hz), as well as for lighting and motor run applications.For the latter, AC capacitors are used in conjunction with asynchronous motors on single-phase mains supplies. They are designed for 50 or 60 Hz systems.


Applications:Asynchronous motors、Air conditioning、Domestic appliances、Compressors/pumps/garage、door openers、 Awning drives、 Heat pumps ets.


****Specifications****
Standard temperature
-40℃ ~ +70℃
Voltages Ratings
250V ~ 500V AC
Capacitance Range
0.6~25 uF
Applicable Standard
IEC60252-1:2011,GB/T3667.1-2005、UL810、EN60252-1:2011


Q: What are the differences between capacitors and capacitors?
Capacitance, resistance, inductance is physical quantity. Capacitors, resistors, inductors are components that have a specific physical quantity (capacitance, resistance, inductance).
Q: How to use the capacitor
High temperature no load test test, high temperature and high humidity load test, temperature jerk test and so may lead to increased leakage current. Therefore, do not apply solid-state aluminum capacitors to leak-current-sensitive circuits
Q: What kind of capacitance can be divided into?
Aluminum electrolytic capacitor It is made of aluminum cylinder negative, which is equipped with liquid electrolyte, insert a curved aluminum belt made of positive electrode. Also need to go through the DC voltage treatment, so that the formation of an oxide film on the positive film to do the media. It is characterized by large capacity, but large leakage, large error, poor stability, often used for AC bypass and filter, when the request is not high when used for signal coupling. Electrolytic capacitors are positive and negative points, the use can not be reversed. There are positive and negative polarity, the use of time, positive and negative do not reverse.
Q: Cd capacitance to express what
Mainly used in high voltage, high current and high pulse circuit, such as buffer, energy converter, switching power supply, inverter and inverter protection circuit, especially for IGBT, SCR, Darlington line For absorption capacitors.
Q: Does the size of the capacitor affect the power consumption?
The capacitance of the symbol is C. In the international unit system, the capacitance of the unit is Farah, referred to as the law, the symbol is F. a capacitor, if the battery with a library when the potential difference between the two is 1 volt, the capacitor capacitor is 1
Q: What is the principle of capacitance isolation?
When the capacitor is connected to the AC circuit, there is also a charging process in which the charge is stopped when the capacitor voltage is equal to the supply voltage, and then the power supply voltage drops and the capacitor begins to discharge.
Q: What is the difference between the power capacitor and the complement?
Input compensation: three-phase co-fill capacitor input, the three groups of capacitors at the same time. The sub-capacitor can be put into operation separately.
Q: What is the difference between the reactor and the capacitor?
Reactor is the inductive load, there are series and parallel in series, the series is mainly used to limit the short-circuit current, parallel mainly used for ultra-high voltage long-distance transmission, the compensation line capacitance. Capacitors are capacitive loads that are used primarily to compensate for reactive and energy storage. Inductance and capacitance combinations for filtering and so on.
Q: Does anyone know the difference between the stray inductance of the capacitor and the parasitic inductance?
This impedance can not be ignored in the presence of high frequency current, with particular note that the bypass capacitor needs to pass through the two vias when connecting the power plane and the formation so that the parasitic inductance of the vias is multiplied.
Q: Why some Y capacitor is very small, and some Y capacitor is very large?
At the AC power input, it is generally necessary to add three safety capacitors to suppress EMI conduction interference. AC power input is divided into three terminals: FireWire (L) / Neutral (N) / Ground (G). Between the line of fire and the ground and between the zero line and ground in parallel with the capacitor, generally referred to as Y capacitor. The two Y-capacitor connection position is more critical, must meet the relevant safety standards, to prevent electronic equipment leakage or chassis charged, easy to endanger personal safety and life.