Round Aluminium Air Diffuer with Steel Damper
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 500000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification of Air Diffuser
Aluminium Round Diffuser
Supplying Air Diffusers
-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed
-Powder Coated RAL 9010/9016
Usage of Air Diffuser
The grille is suitable for ceilling sidewall, soffit or cill mounting and may be used for supply or extract applications.
Typical installations include offices, shops, hotels and most commercial or industrial buildings.
Available as standard in white polyester powder coat finish.
Other polyester powder coat finishes are also available as an option.
Specification of Air Diffuser
round air diffusers | ||
circular ceiling diffuser | ||
round diffuser | ||
NECK SIZE(mm) | DESCRIPTION OF GOODS | |
Diameter | 100 | 1. Product name: round air diffuser |
Diameter | 125 | 2. Material: aluminum |
Diameter | 150 | 3. Powder coated: standard color, RAL 9010/9016聽 |
Diameter | 160 | 4. Damper with |
Diameter | 200 | 5. reduce the flow resistance and noise. |
Diameter | 250 | 6. The products are easy to install and clean. |
Diameter | 300 | 7.聽 adapt to centrel air-conditioning systems. |
Diameter | 350 | 8. other size/colors available. |
Dimensions,colors,thickness, finished, disigns and other specification can be customized according to customers' request |
Products Show
Packing & Shipment
Packing:
PO shrink film bag for each pcs, ourter by export carton
PVC film + 4 plastic protection corners + carton box + closed wooden box optionally.
Shipping:
within 21 days after deposit
Packing:
PO shrink film bag for each pcs, ourter by export carton
PVC film + 4 plastic protection corners + carton box + closed wooden box optionally.
Shipping:
within 21 days after deposit
FAQ:
1, What's size do u have for round type diffuser?
A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm聽
2, Do u still have other types ?
A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc
3, What's the most early delivery time?
A: Within 25 days for each 40'fcl
- Q: The air-conditioning compressor is stuck. Is there any way to repair it?
- When necessary the appropriate starting capacitor capacity compressor for the specifications of a compressor can be normal to try to start up, and can be used with a screwdriver on the reverse way of trying to solve the compressor body.
- Q: What are the parts of the outdoor unit?
- Start capacitor compressor refrigerant cycle for capillary tube respectively high pressure pipe and low pressure pipe
- Q: How to deal with the liquid hammer phenomenon of compressor
- If the compressor has occurred abnormal impact (knock or impact) sound, and will strongly shake vibration, indicating that the liquid is in the attack. Slight short term abnormal shocks may be of little concern, but often prolonged and heavy fluid shocks cause compressor deformation, rupture, and even breakage, which directly damages the compressor
- Q: What is the purpose of a two-stage compression refrigeration cycle?
- The traditional air conditioning system can only achieve the lowest heat at minus 7 degrees Celsius environment itself, and adopting the two-stage inverter air conditioner double stage compressor can be achieved in the limit condition minus 30 DEG C under strong heating
- Q: What are the air compressors for?
- The air force: the traditional pneumatic tools, drilling machine, pneumatic, pneumatic wrench, pneumatic sandblasting
- Q: What are the risk factors of condensers?
- Combustible components are mainly acetylene and other hydrocarbons, acetylene is the most dangerous, the solubility in liquid oxygen is very low (5.6 * 10-6mg/L), it is easy to precipitate in solid state and cause explosion.
- Q: What is the cause of the overload of the air conditioning compressor?
- The outdoor condenser is out of air and has obstructions
- Q: What are the types of compressors?
- Displacement compressor is the ability to limit a certain amount of continuous air flow to a closed space, increasing the pressure
- Q: How to repair air conditioning compressor?
- Check the compressor does not start trouble, such as the bottom of the capacitor drum, remove the capacitor, the bottom placed in the plane, such as standing instability, about rocking, then the compressor capacitor must be damaged, can be replaced directly
- Q: What are the system components of condensers?
- After the liquid refrigerant absorbs heat by cooling objects in the evaporator, vaporized into high temperature low pressure steam, steam compressor suction, compressed into high temperature and high pressure discharged into the condenser, the condenser to a cooling medium (water or air) heat, condensing high-pressure liquid, through the throttle valve throttle for low temperature and low pressure refrigerant enter again the evaporator absorbs heat of vaporization, achieve the purpose of refrigeration cycle
Send your message to us
Round Aluminium Air Diffuer with Steel Damper
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 500000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords