• motor running capacitor round with metal case System 1
  • motor running capacitor round with metal case System 2
  • motor running capacitor round with metal case System 3
motor running capacitor round with metal case

motor running capacitor round with metal case

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
400000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Type: Polypropylene Film CapacitorModel Number: CBB65

  • Application: AC / Motor

  • Package Type: Other

  • Capacitance: 5uf~100uf

  • Rated Voltage: 450V

  • Packaging & Delivery

  • Operating Temperature: -40~85


Packaging Details:Normal packing:slide card with double blister We can also packing according to customer's requests. Accurate packing list will be sent on request.
Delivery Detail:15days

Specifications

low dissipation,good self-healing ,steady electric performance,etc.it is applied in air-condition,refrigerator,motor,etc.

Technical parameter

Ambient

Temp

Rated

Voltage

(VAC)

Capacitance

Range

(μF)

Test Voltage

(VAC)

Dissipation

Factor

Operating

Frequency

-40~85°C

150~450

5~100

T-T:2Un/2S

T-C:2200VAC/2S

Tanδ≤0.002(100HZ)

50/60HZ

Executing standards:IEC60252,UL810,EN60252,VDE0560-8,GB/T3667.1-2005

Capacitance tolerance : ±5% or fulfilled upon request .



Q:What is the difference between the reactor and the capacitor?
Reactor is the inductive load, there are series and parallel in series, the series is mainly used to limit the short-circuit current, parallel mainly used for ultra-high voltage long-distance transmission, the compensation line capacitance. Capacitors are capacitive loads that are used primarily to compensate for reactive and energy storage. Inductance and capacitance combinations for filtering and so on.
Q:Cd capacitance to express what
Mainly speaking, the winding process of the capacitor is a non-inductive winding structure (relative, there is a sense of winding structure), in fact, no sense of capacitance is not no inductance, but the inductance is very small, for high-frequency operation of the capacitor, We emphasize no sense. In fact, the inductance is small. From this point of view, almost all of the metal film capacitors are no sense
Q:What kind of capacitance can be divided into?
Commonly used capacitor structure and characteristics Commonly used capacitors can be divided into their dielectric materials electrolytic capacitors, mica capacitors, ceramic capacitors, glass glaze capacitors and so on.
Q:What is the relationship between capacitance and voltage?
In your case, you can think of two capacitors as two containers, 5v capacity than 10v half (because they are 0.01uF),
Q:How to identify high voltage capacitors is good or bad
Test the resistance at both ends with a multimeter. If the use of a pointer multimeter, and most of the same capacitor, you can see the pointer from small to large a swing process. The difference is not the last return to infinity, but 10m. Inexperienced friends may think that the capacitor breakdown or leakage, in fact, not.
Q:What is the phase-shifting capacitor, what is the difference between it and the general capacitor
And the phase-shifting capacitor has the function of changing the phase of the alternating current signal in addition to the characteristics of the general capacitor. The answer can be compensated by the power factor compensation in parallel with the phase-shifting capacitor, and the phase-shifting capacitor can be used to produce the phase-shifting capacitor fault diagnosis device.
Q:How to use the capacitor
Solid-state aluminum capacitors have positive and negative points, do not reverse the solid-state aluminum capacitors, reverse solid capacitors can lead to a sharp increase in leakage current or reduced service life.
Q:Why some Y capacitor is very small, and some Y capacitor is very large?
To charge the power cord for long periods of time. The safety standard stipulates that the voltage (or ground potential) charged at both ends of the power cord plug must be less than 30% of the original rated operating voltage within two seconds when the machine power cord is in operation.
Q:What is the difference between the power capacitor and the complement?
Input compensation: three-phase co-fill capacitor input, the three groups of capacitors at the same time. The sub-capacitor can be put into operation separately.
Q:On the ground resistance, what role the capacitor
The capacitor used in the bypass circuit is called the bypass capacitor. If the signal is removed from the signal in the circuit, the bypass capacitor circuit can be used. According to the frequency of the removed signal, there is a full frequency domain (all AC signals ) Bypass capacitor circuit and high frequency bypass capacitor circuit.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords