Place of Origin:Anhui China (Mainland)Brand Name:Mascotop/OEMModel Number:CBB66
Type:
Polypropylene Film Capacitor,Anhui Mascotop Motor Capacitors (Oil Type)
Application:AC / MotorPackage Type:Through Hole
Capacitance:30~38uFRated Voltage:540VAC~600VACOperating Temperature:105℃
Material of Capacitors:MPP/Al-PP/Resin/OilCan of Capacitors:AluminumCapacitance of Capacitors:30~38uf
Voltage of Capacitors:540VAC,600VACMax. Temp70℃,85℃,105℃Class of Safety protection of Capacitors:P1/P2
Capacitance deviation:-+3%,-+5%Operating Life of Capacitors:
3000h(Class C), 10000h(Class B)
Application of Capacitors:metal halide lamp

Packaging & Delivery

Packaging Detail:Export Standard Carton For Electronic Motor Capacitors
Delivery Detail:10-25days

CBB66 Special Capacitorfor Lighting Metal Halide Lamp

Technical features:

Product type

Electronic Motor Capacitor

Capacitance range

30~38uF

Capacitance deviation

±5% or according to customers’ requests.

Rated Voltage

540VAC,600VAC

Rated frequency

50/60Hz

Operating Temperature

-40°C~+105°C

Class of safety protection

P1, P2

Testing voltage

T-T:2.0Un/60S

Insulation resistance

>=3000s

Tangent of loss angle of a capacitor

tanσ≤0.002 (100Hz)

Life Span

Class B(10000h), Class C(3000h)

SizeAccording to chart or users requirement

Executing standards:GB18489,GB/T18504,IEC61048,IEC61049,EN61048,EN61049,UL810

Capacitance tolerance : ±3% ,±5%  or fulfilled upon request .


Q: Low voltage capacitor voltage 0.45 and 0.4 What is the difference between usage
Can be used in the low-voltage three-phase power lines on the line, but the level of different pressure, connected to the 400V line, 450V capacitor capacity is 79% of rated capacity, 400V capacitor capacity is rated capacity. In the use of life on the 450V longer than 400V
Q: How to use the capacitor
High temperature no load test test, high temperature and high humidity load test, temperature jerk test and so may lead to increased leakage current. Therefore, do not apply solid-state aluminum capacitors to leak-current-sensitive circuits
Q: What is the phase-shifting capacitor, what is the difference between it and the general capacitor
And the phase-shifting capacitor has the function of changing the phase of the alternating current signal in addition to the characteristics of the general capacitor. The answer can be compensated by the power factor compensation in parallel with the phase-shifting capacitor, and the phase-shifting capacitor can be used to produce the phase-shifting capacitor fault diagnosis device.
Q: Does the size of the capacitor affect the power consumption?
The capacitance is the physical quantity that characterizes the capacity of the capacitor to charge the charge.We charge the capacitance of the capacitor by increasing the potential difference between the two plates of the capacitor by one volt.
Q: What is the principle of capacitance isolation?
The structure of the capacitor is two plates, separated by a layer of insulator, so under normal circumstances the capacitor is no current through (unless the middle of the insulation was breakdown).
Q: What is the difference between the power capacitor and the complement?
In fact, in the case of three-phase imbalance, but also a total complement and sub-all have, the three-phase power factor, respectively, 0.53,0.67,0.71, then, in the 0.71 above this part, The reactive power required by the other parts of the two phases is compensated by tipping.
Q: Why some Y capacitor is very small, and some Y capacitor is very large?
They all belong to the safety capacitor, which requires the capacitance value can not be too large, and the pressure must be higher. Under normal circumstances, work in the subtropical machine, the required leakage current can not exceed 0.7mA; work in the temperate machine, the required leakage current can not exceed 0.35mA. Therefore, the total capacity of the Y capacitor is generally not more than 4700PF (472).
Q: How does the capacitor work? What does it do?
The bypass capacitor is an energy storage device that provides energy to the local device, which can equalize the output of the regulator and reduce the load demand. Like a small rechargeable battery, the bypass capacitor can be charged and discharged to the device. To minimize the impedance, the bypass capacitor should be as close as possible to the load device's power supply pin and ground pin.
Q: Capacitance for AC and DC effects?
Potential has a concept of space, referring to the electric field to a Coulomb charge from A to B work 1 joules, A on the B potential is 1 volt. The concept of potential for the circuit, specify a point of the circuit for the 0 potential, the other points are based on the point of the voltage is the potential of the other points. Electromotive force used in batteries, generators, is the power to generate voltage.
Q: What is the difference between polyester film capacitors and ceramic capacitors?
Different components of the ceramic, its dielectric constant and temperature coefficient is different, the temperature coefficient range is wide, easy to make different temperature coefficient of the capacitor, used as a temperature compensation capacitor.