• Led Strip Light 2835 30 Led Per Meters IP68 PU GLUE PLUS TUBE System 1
  • Led Strip Light 2835 30 Led Per Meters IP68 PU GLUE PLUS TUBE System 2
  • Led Strip Light 2835 30 Led Per Meters IP68 PU GLUE PLUS TUBE System 3
  • Led Strip Light 2835 30 Led Per Meters IP68 PU GLUE PLUS TUBE System 4
Led Strip Light 2835 30 Led Per Meters IP68 PU GLUE PLUS TUBE

Led Strip Light 2835 30 Led Per Meters IP68 PU GLUE PLUS TUBE

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
1000000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

        1). Product Description:                                                                              

        1).  Products Name: Led flexible strip light,DC12V Led strip light, AC220V Led strip light, etc.

        2).  Input voltage (V): 85-265V AC

        3).  Output Voltage (V): DC12V or DC24V or AC220V, AC110V

        4).  SMD Type: SMD3528, SMD5050, SMD2835, SMD3014, SMD5630, SMD5730,SMD335,

        5).  Power Consumption Per Piece: 0.08w forSMD3528,  0.24w for SMD5050, etc. 0.10wfor SMD2835, or 0.20w for SMD2835,  0.5Wfor SMD5730, etc

        6).  LED Qty per meter: 30 LEDs/m, 60 LEDs/m, 96 LEDs/m,120 LEDs/m, 240 LEDs/m, others available.

        7).  Width: 4mm, 5mm, 6mm, 8mm, 10mm, 12mm widthPCB board,  White PCB Board or Yellow PCBBoard, Black PCB Board, etc.

        8).  Color Temperature (CCT): Warmwhite:2800-3500K, Natural white:4000-5000K, White:6000-7000K, Cool White:8000-15000K, other customized color available.

        9).  Emitting Color: Warm white, Natural white,White, Red, Green, Blue, Yellow, Pink, Purple, RGB.

        10).  Power per meter: 4.8W/M, 7.68W/M, 9.6W/M,3.6W/M, 7.2W/M, 14.4W/M, and others

        11).  Luminous Flux ( Lumens ): 4-5LM/pcs, 5-6LM/pc, 6-7LM/pcs,7-8LM/pcs, for SMD3528, and 11-13LM/pcs, 13-15LM/pcs, 16-18LM/pcs, 18-20LM/pcs,  for SMD5050, etc.

        12).  Waterproof Type: IP20, IP22, IP44, IP54,IP65, IP67, IP68,  Non-waterproof,  PU glue waterproof or Epoxy glue waterproof,  Better silicon waterproof,  Hollow tube waterproof,  PVC tube with silicon inside waterproof,  Phosphor Colourful Waterproof.

        13).  LED Chip Brand: Epistar, Brightlux, we do notuse Chinese Chips

        14).  Chip Pcs: 1 chip, 3 chips.

        15).  Certification: CE-EMC,CE-LVD, RoHS, CCC ,UL, FCC, RoHS, UL, ERP.

        16).  Drive Current Per Piece: 16mA, 18mA, 20mA,58mA, 60mA, 62mA, etc,

        17).  Power Factor: >90%

        18).  CRI (Ra>):80 Ra, others available.

        19).  Operating Temperature (): 40 to +50 degree Celsius

        20).  Life-span (Hour): 30000 ~  50000

        21).  Lamp Body Material: Copper

        22).  Place of Origin: Shenzhen, China (Mainland)

        23).  Brand Name: CMAX

        24).  Model Number: KU-3528-5050-60D,  many differenttype of models, please refer to our pricelist

        25).  Warranty: 1,2 and 3 years and 5 years

        26).  Beam Angle: 120 degree

        27).  Packaging Details: 1 meter/roll, 3meters/roll, 5meters/roll, 10 meters/roll, 40 meters/roll, etc,

        28).  Standard export package.

        29).  Light Decay: less than 3% after 1000 hoursconstant work

        30).  PCB Board Color: White or Yellow (Brown)

        31).  Layer thickness: single pcb board, double pcb board.



Q: LED lamp installation drawing, which 5050 and 5730 are good?
More say one for reference, Shenzhen manufacturers generally do more exports, quality will be better, Zhongshan do domestic market, cheap, of course, a penny of the goods
Q: LED how to distinguish between good and bad?
Light production because the threshold is low, so many people on this project. But people have experience still have a way to identify, regular LED lamp manufacturer and copycat version of the LED lamp (i.e. in the rental by manual operation of the products produced) is a can come out from the appearance of the eye.
Q: The problem of residual light in LED lamp after power failure
In fact, it is not the induction voltage, but the voltage of the alternating current fire line to the ground. In fact, this phenomenon occurs in fluorescent lamps. In general, as long as the switch off the fire line, this phenomenon will be eliminated.
Q: How does the LED light belt power supply?
Assign a dedicated plug (plug to the transformer) to the LED light belt to power the battery.
Q: One meter band of LED lights. Let me cut it in the middle. Then I found a thread and put it together. Why didn't it turn on?.
Then the outside two main lines also need welding.Be sure to wrap it with insulating tape. Don't short-circuit it with the outside. The outside is 220V high voltage.
Q: Can anyone tell me what's the difference between LED lights and indoor and outdoor installations?
Zhongshan bright lighting LED lamp production as an example, behind each LED lamp belt are affixed with self-adhesive 3M double-sided adhesive, the installation can be directly off the surface of the 3M double-sided adhesive stickers, and then the lamp strip is fixed on the installation place, hand press flat is good. As for some places need to turn or grow, what should I do? Very simple, LED light belt is a series of 3 LED as a series of parallel circuit structure, each 3 LED that can be cut alone.
Q: 10 meters long, 24 volts, LED lights with 1 hours, how much power consumption?
Power is the measure of the transmission rate of energy. In a DC circuit, it is the product of the voltage V and the current A; it is much more complicated in the AC system. Whether they are high voltage or low voltage LED light belts, they convert AC to DC to work.
Q: Is the LED belt with a constant voltage transformer or a constant current transformer?
Constant current transformers are generally current transformers. The principle of current transformer is based on the principle of electromagnetic induction. The current transformer consists of a closed core and windings. The number of the primary winding turns its little string in the current need to measure the line, so it is often all two line current flows through the primary winding turns are more connected in series of measuring and protection circuit, current transformer in operation, the two side loop it from the beginning to the end is closed, so the measurement instruments and protection circuit impedance in series with the coil current transformer is very small, close to the working state of short circuit. The current transformer is to change the primary side large current into two side small current to measure, the two side can not open circuit.
Q: 5730led hard lamp, with one meter long and 72 beads, what is the power?
This is actually very difficult to calculate, because the current and voltage using the actual do not know, if the maximum value is 5730, each 0.5W, current to 150MA, when using high pressure constant current drive, the 72 is 36W
Q: LED how to connect the lamp band, 12 volt battery is not damaged
LED lights power supply for 3V, four series as a group, just for 12V, pay attention to positive and negative pole, do not take the wrong.