• LED Panel Light  600X600MM 54W System 1
  • LED Panel Light  600X600MM 54W System 2
LED Panel Light  600X600MM 54W

LED Panel Light 600X600MM 54W

Ref Price:
$28.00 / set get latest price
Loading Port:
SHENZHEN
Payment Terms:
TT or LC
Min Order Qty:
1000 set
Supply Capability:
1000000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


 

RECESSED LED PANEL LIGHT 600X600mm/Mounting size 595X595mm 54W


New generaton of Lighting



Main Features of LED PANEL Light 


 

1. Light efficiency: 80-90lm/w.
2. ColorTemperature :3000~6000K
3. CRI : Ra>75,RA80
4. Working Temp: -25~ 50 c 

5. Power factor:≥0.9

6. Shell protection:IP44

7. Size:600x600mm,300x 300mm,1200x300mm,1200x600mm

8. Material:PC+AL


Advantages of LED PANEL LIGHT

 

2.High luminous efficiency , High color rendition ,Good heat dissipatio .Instant start,no frequent flash ,Lighting softly,protect eyesight

Low power consumption , Low light degradation

 

Model:FR-PF-02
Power:

30W,36W,40W,48W,54W,60W

Light  Efficiency:80lm/W
Power factor:>0.9
Luminous flux:1280LM--5760lm
CCT:

WW:2700-3200k

NW:3800-4500K

CW:5300-7000K

Ip Rating:

44

Body Material:

Aluminum

Optional Power:
Dimension   (mm) :

300x300 600x600 300x600 300x1200mm

Certificate:

CE,RoHS


LED Panel Light  36W


LED Panel Light  36W


LED Panel Light  36W

LED Panel Light  36W


 

FAQ:


Q: What is your Led Panel Light use ?

A: The lighting source


Q: What is the size CNBM can offer ?

A: 30x30cm,60x60cm,120x30cm,62x62cm,120x60cm


Q: What is the Power Factor of your LED Light ?

A :0.5 or 0.9 


Q: What is the Color Rendex Index ?

A: RA 70,RA80.RA90


Q: What is the light efficiency of CNBM Led Panel Light ?

A: 70LM/W,80LM/W,90LM/W upto 110LM/W


Q: Which kind of mounting solutions of your LED PANEL LIGHT ?

A: Recessed Type, Suspension Grid,Surfaced Mounted etc 


Q: What is your LED Warranty Terms ?

A: 2 YEARS - 5 Years 



Q: How long is 50,000 hours
A:Based on how long a fixture is illuminated per day, here's what 50,00 works out to be

Lifespan Hours of Operation: 50,000 hours is

24 hours per day: 5.7 Years

18 hours per day: 7.4 years

12 hours per day: 11.4 years

 8 hours per day: 17.1 years


Q: How are the LED Lights evaluated?

A: Lumens produced is just one factor of the performance of a light, and sometimes it is misleading.

To understand how to fully evaluate the LED product, we need to look the overall system efficiency, optical control, thermal management of the LEDs.


Another factor that can also be very misleading is the life of an LED lights, the life time is defined by how long will the light last before the fixture reaches 30 percent lumen depreciation. For example, most time the LED Light has life time of 50,000 hours, it doesn't mean that after 50,000 hours, the LED Bulb won't work at all, it will still be working and it's just the Lumens it emitts is 30% less than when it's first used.


Optical control is very simple to understand, it's the technique used to emit as much the light the light sourced produced as it can.


Thermal managment is another important factor for evaluation of the LED product, as we all know, if the one electric appliance is very hot when it's used, it actually wastes a lot of energy as this energy is used to produce heat, not used for the goal of the appliance.


To maintain the extended life of the fixture, LEDs need to be shed heat that builds inside the fixture. A low junction temperature is key to effective thermal management. The heat pipe assembly contains heat pipes that move heat away from the LEDs and the circuit board quickly and effectively. Through this effective thermal management design, the fixture is guaranteed to operate at the proper temperatures.


As the Department of Energy concluded in its Solid-State Lighting Commercial Product Testing Program: "Until the field of SSL technologies and supporting knowledge matures, any claims regarding performance of SSL luminaires should be based on overall luminaire efficacy (i.e., from testing of the entire luminaire, including LEDs, drivers heat sinks, optical lenses and housing), to avoid misleading buyers and causing long-term damage to the SSL market"




Q: How is the indoor installation of the LED panel lamp convenient?!
1, hanging: first in the LED panel lights back mounted on the suspension member, then connect the lanyard on it. Consumers must pay attention to ask, understand clearly hanging components is the manufacturer's standard parts or buy parts?.2, suction top type: first in the ceiling to play a few holes, and then LED panel light slide into the suction ceiling frame installed on the ceiling, fixed three sides. Then slide the panel light into it, and then screw the frame around the fourth edge. Convenient, simple and time-saving.3, embedded type: the first sheet metal groove is arranged on the ceiling, and then the bracket is fixed at the back of LED panel light pieces protruding outward, and then into the panel light, the sheet metal bracket and the ceiling of the anastomotic groove can be fixed on the ceiling. But because of the different thickness of the ceiling, it is necessary to adjust the height between the lamp face and the bracket, otherwise it will cause the LED panel lamp to be higher or lower than the ceiling surface. In general, suspension mounted LED panel lights are best for aquarium lighting, while ceiling mounted is the most common and easiest way to do so.
Q: How do you remove the LED panel light?
Look at the installation book, in turn, on the lineReminder: remove the lamp when power off, careful shock??To adopt Oh (V are your)
Q: What are the accessories for the LED panel light?
Corner screw buckle light board cover film adhesive foam coaxial line rectangular stickers public lamp board, power supply, aluminum frame, light guide plate,
Q: Can LED panel lCan LED panel lamp be used in table tennis hall?amp be used in table tennis hall?
According to the provisions of the design standard of national building lighting illumination standard table tennis table: the project value for the training of 750lx; the game to reach 1000lx, LED because of its advantages of no delay, no noise, no stroboscopic, very suitable for table tennis hall of lighting, but if the venue space is too high, it is difficult to achieve LED panel lights standard illuminance value.
Q: What is the light source of the LED panel light?
The LED panel light source is the LED chip. It is placed on the 2 side of the panel light, and the light is uniformly distributed to the whole light surface through the light guide plate on the back
Q: What's the difference between the LED panel light and the LED ultra-thin panel light?
Personally, I think LED panel light or side light-emitting products, cost-effective to be higher!
Q: Differences between office buildings, office lighting, LED panel lights and traditional lamps
Uniformity of color temperature uniformityOffice lighting LED panel light use a plurality of luminous body. The luminous body and the luminous body between the color is different, also have certain differences in different angles to observe the color will be slightly different, but the traditional lamp adopts a luminous body composed of a single, there is no color difference the problem;
Q: What material does the LED panel light need, such as the light guide plate or something?
The light guide plate (light guide plate) is the use of optical grade /PC acrylic sheet, and then use high-tech materials with high reflectivity and absorption of light, the optical grade acrylic bottom with UV screen printed guide dot printing technology. The use of optical grade acrylic sheet drawing out the lights stay in optical grade acrylic sheet surface, when the light guide to each spot, the reflected light will spread to all angles, and then destroy the reflection condition by the light guide plate is injection.
Q: How can I change the lamp of integrated ceiling lamp in the kitchen? I want to change to LED panel lamp
Can you take a picture and show me your integrated ceiling?
Q: How many watts is the LED panel light?
600*600 (instead of the traditional 3*20W grille lamp) input power of about 30W, luminous flux can reach 3000LM, 1200*600 (instead of the traditional 3*40W grille lamp) input power of about 60W, luminous flux of up to 6000LM

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords