• GDPULS62-9 radar level meter with measurement range of 0-20M System 1
  • GDPULS62-9 radar level meter with measurement range of 0-20M System 2
  • GDPULS62-9 radar level meter with measurement range of 0-20M System 3
  • GDPULS62-9 radar level meter with measurement range of 0-20M System 4
  • GDPULS62-9 radar level meter with measurement range of 0-20M System 5
  • GDPULS62-9 radar level meter with measurement range of 0-20M System 6
GDPULS62-9 radar level meter with measurement range of 0-20M

GDPULS62-9 radar level meter with measurement range of 0-20M

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
5000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.

Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.

Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.

 

Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel. 
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.

 

Input:

 

the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.

 

When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)

Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.

 

4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire) 

 

CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.

 

Q: Which is good between pneumatic tools and power tools?
The use of pneumatic tools:1., the air is easy to obtain, and the work pressure is low, the used air can be discharged locally, without the need to recover the pipeline2. gas viscosity is small, flow resistance loss is small, easy to central gas supply and long-distance transportation3. pneumatic actuator, high movement speed4. the pneumatic system has a strong adaptability to the environment. It can work reliably in a wide temperature range, humid and dusty environment, with a slight leakage, no pollution to the environment, no fire and explosion hazards, and safe use5., simple structure, convenient maintenance and low cost6. long life of pneumatic components7. pneumatic actuators of the hydraulic output than small, fast, strong adaptability, can exercise in the flammable, explosive, heavy, damp, the impact of the harsh environment, no environmental pollution, long service life, simple structure, easy maintenance, low price.
Q: What are the common rotors of power tools?
Hammer and drill: used for concrete, brick and building components on drilling, slotting, dehairing. With expansion bolts, installation can improve the speed and quality of pipeline, machine equipment; impact hammer principle is to rely on the internal movement of the piston impact force, impact principle of impact drill is running in gear impact force, so the impact hammer is greater.Concrete vibrator: used for pouring concrete foundation and reinforced concrete members, tamping concrete to eliminate air holes and increase strength. The high-frequency disturbing power of the electric direct acting vibrator is driven by an electric motor to rotate the eccentric block, and the motor is powered by an 150Hz or 200Hz intermediate frequency power supply.The planer: used for planing wood or wood structure, mounted on the bench can be used as a small bench plane. The planer cutter shaft by the motor shaft through the belt drive.Electric tools commonly used bearing type: 606, 607, 608, 626, 627, 628, 629, 6000, 6001, 6003, 6004, 6200, 6201, 6202, 6203, 6303, 61907, 688 commonly used carbon brush models: 50#, 408#, 43#, 44#, 303#, 21#, 6M etc.
Q: Is Li Xiang power tool good?
About the same price, choose a good reputation, East into good
Q: What's the role of carbon brushes in electric tools?
In addition to induction type AC asynchronous motors, there is no outside. Other motors are provided, as long as the rotor has a reversing ring.The principle of electric power generation is that a magnetic field cuts a wire to produce an electric current in the wire. The generator cuts the wires by rotating the magnetic field. A rotating magnetic field is a rotor, and the wire to be cut is a stator.
Q: What's the name of an electric tool for riveting screws into wood? Not understand!
If the factory is assembled, use an electric screwdriver! Only suitable for twisting small screws! Because the torque itself is not large! Like you twist it on a wood, use a Zigong drill, or a rechargeable drill! Because of these two belts with adjustable torque! Unlike an electric drill, it always turns that way! This torque is automatically separated by reaching a certain torque! If you screw a big screw, it's an electric wrench!
Q: What other tools are there for the furniture except the pistol hole?
It is mainly used in construction, decoration, furniture industry, opening for objects or objects in the past, also known as hammer in some industries.Well, there are more drilling tools on the market now.
Q: Why hand grinding sand turbine, electric drill, impact drill and other power tools plug is two, plug is not three plug
In recent years, leakage protection performance and the reliability greatly, has become a standard power supply, reliability of human protection over ground protection to a certain extent, but the impact of grounding protection and leakage protection to human body protection, so many hand-held electric tools to cancel the earthing protection, relying instead on leakage protector. And use the two eye plug.Look at the instructions for the hand-held power tools with two plugs. All require that the power supply be equipped with an electric leakage protector.
Q: Is the motor of an electric tool the alternating current motor or the direct current motor?
The series motor is usually used. The series motor is connected in series because the stator and rotor windings are connected together, so when the current is reversed, the magnetic field is reversed, so the torque direction remains the same. However, according to this principle, the motor works at 180 degrees after the torque is gone, so even the AC motor, but also need to reverse, in order to work like a DC motor.The rectifier also needs to be rectified if it is operated under the direct current. The rectifier bridge is very small. On the circuit board, there are four diodes close together, mostly rectifier bridge
Q: What kind of material does the power tool case have?
In 1895, the German overtone produced the world's first direct current drill. The outer shell is made of cast iron and can drill holes in the steel plate 4mm. Then there was a three-phase power frequency (50Hz) electric drill, but the motor speed failed to break through the 3000r/min. In 1914, there was a single-phase electric motor driven by a series of exciting motors, and the motor speed was over 10000r/min. In 1927, the power supply frequency of intermediate frequency electric tool 150~200Hz, it not only has the advantages of high speed single-phase series motor, and has the advantages of simple structure, reliable three-phase motor, but because the need if current supply is limited.
Q: How to detect the rotor of power tools?
The rotor has no force. Most of them are burned out of the rotor, and many rotors can be removed if they are removed. One can distinguish, such as commutator commutator shedding, excessive wear. Have the commutator between electrodes and arc erosion serious. Rotor winding, inhaled by the fan, damage caused by damage to the rotor.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches