• China TH-440 Full-digital Ultrasound Diagnostic System  FOR Medical Apparatus System 1
  • China TH-440 Full-digital Ultrasound Diagnostic System  FOR Medical Apparatus System 2
China TH-440 Full-digital Ultrasound Diagnostic System  FOR Medical Apparatus

China TH-440 Full-digital Ultrasound Diagnostic System FOR Medical Apparatus

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Features:
* Multi-application: abdomen, OB/GYN, vagina, small parts, urology, peripheral vessels,
cardiac, rectum, pediatric, biopsy
* High-precision DBF
* PC platform
* 15 inch LED display
* Multi-frequency transducer series
* Max frequency up to 10MHz
* English, French, Spanish, Germany, Italian, Russian, Portuguese interface
* Supportive of all PC printers and video printers
* 3D Function
* Built-in battery(around 2 - 3 hours)
Standard configuration:
TH-400 main unit
15 inch LED montor
Two transducer connectors
THI
Permanent storage of 5000 images
Max 512-frames of Cine Loop
Two USB ports
DICOM 3.0
Measurement & calculation software packages
Electronic convex array transducer: CA3.5MHz/R50 (2.0/3.0/3.5/4.0/4.5MHZ)

Options:
Electronic linear array transducer: LA7.5MHz/L40 (6.5/7.0/7.5/8.0/10.0MHz)
Electronic endocavity transducer: EV6.5MHz/R10 (5.5/6.0/6.5/7.0/7.5MHz)
Electronic micro-convex array transducer: CA3.2MHz/R20 (2.5/3.0/3.2/4.0/4.5MHz)
Built-in 160/320/500G HDD(option)
Needle-guided brackets
Footswitch
Mobile trolley
Technical Specifications:
General Descriptions
Imaging mode: B, B+B, B+M, M, 4B, 9B
Gray scale: 256
Display: 15″LED
Transducer frequency: 2.0 ~ 10MHz
Transducer connector: 2
Beam-forming: DBF (Digital Beam-forming)
DRF (Dynamic Receiving Focusing)
DFS (Dynamic Frequency Scan)
RDA (Real-time Dynamic Aperture)
DRA (Dynamic Receiving Apodization)
Scanning angle (°) : from 24 to 156.6 (depending on transducers)
Scanning depth (mm) : from 20 to 250 (depending on transducers)
Image Processing
Pre-processing: 8-segment TGC
gross gain
dynamic range (≥120db)
Pre Gray
smooth
acoustic power adjustment
scanning angle selection
Post-processing: edge enhancement

frame correlation
line correlation
γ-correction
contrast
brightness
black-white reverse
left-right reverse
up-down reverse


Functions
Cine loop: 512-frame cine loop memory, depend on the resolution
Storage media: permanent storage of 5000 images, USB, built-in 160/320/500GB HDD
(option)
Zoom: real-time partial zoom, up to 10 times
Measurement & Calculation
B-mode: distance, circumference, area, volume, angle, residual urine volume,
histogram, profile
M-mode: distance, time, velocity, heart rate
Software packages: abdomen, gynecology, obstetrics, cardiology, small parts, peripheral
vessels, orthopedics, urology
Others
Peripheral port: Video output 1(option)
USB port 2
DICOM3.0 1
Power supply: 100~240V±10% 50/60HZ
Net weight: 4Kg
Dimension: 362mm x 340mm x 60mm
NOTE: specifications subject to change without prior notice.
SCM Version


Features:
* Multi-application: abdomen, OB/GYN, vagina, small parts, urology, peripheral vessels,
cardiac, rectum, pediatric, biopsy
* High-precision DBF
* Multi-frequency transducer series
* Max frequency up to 10MHz
* English, Chinese interface
* 15 inch LCD screen
* Built-in battery(around 3 - 5 hours)
Standard configuration:
TH-400 main unit
15″ LCD monitor
Two transducer connectors
2 USB port
Measurement & calculation software packages
Electronic convex array transducer: CA3.5MHz/R50 (2.0/3.0/3.5/4.0/4.5MHZ)
Options:
Electronic linear array transducer: LA7.5MHz/L40 (6.5/7.0/7.5/8.0/10.0MHz)
Electronic endocavity transducer: EV6.5MHz/R10 (5.5/6.0/6.5/7.0/7.5MHz)
Electronic micro-convex array transducer: CA3.2MHz/R20 (2.5/3.0/3.2/4.0/4.5MHz)
Needle-guided brackets
Footswitch
Mobile trolley

Technical Specifications:
General Descriptions
Imaging mode: B, B+B, B+M, M,4B
Gray scale: 256
Display: 10″non-interlaced
Transducer frequency: 2.0 ~ 10MHz
Transducer connector: 2
Scanning depth (mm) : from 20 to 250 (depending on transducers)
Measurement & Calculation
B-mode: distance, circumference, area, volume, angle, residual urine volume,
histogram, profile
M-mode: distance, time, velocity, heart rate
Software packages: abdomen, gynecology, obstetrics, cardiology, small parts, peripheral
vessels, orthopedics, urology
Others
Peripheral port: video output 1
USB port 2
Power supply: 100~240V±10% 50/60HZ
Gross weight: 4Kg
NOTE: specifications subject to change without prior notice

 

Q: Watching TV, the TV has radiation on the human body; sleep, we usually put the phone on the pillow, the body also radiation, then ask the phone on the human body radiation or TV radiation?
The radiation of the phone is bigger than the TV really ah mobile phone radiation is very obvious ah people will be difficult to improve the pathogen rate ah Mobile phone radiation in the end is harmful or harmless, experts have been arguing over the years. Generally believed that the phone's electromagnetic waves are weak, minimal impact on the human body. However, according to the German "Bild" reported on the 8th, the EU scientists recently confirmed the results of mobile phone radiation can destroy cells and human genetic information with DNA. Twelve research teams from seven EU countries conducted a three-year study on the impact of electromagnetic fields on human cells. Experts have determined that if the cell phone for each kilogram of human tissue radiation value greater than 1.3 watts, it will cause damage to human genetic information, and now the radiation limit is 2 watts per kilogram. In addition, the electromagnetic field will make the body produce a harmful protein. "The radiation from mobile phones would destroy human inheritance, but whether it would hurt our organs," said Fitznell, a journalist from the Franklin University Hospital in Berlin. "We have not yet found evidence in this area." Professor Rudygel from Vienna suggested: "Please do not take risks for your own health, if possible, call your phone as little as possible; if you have to use it, please use your phone next to the house or window, or use a headset So that radiation does not come into direct contact with the brain.
Q: Will the digitalizer, such as reading the input device, electromagnetic radiation is not big? Is there any harm to the body?
In addition, can raise some cactus or cactus and other radiation-resistant flowers, it is said to drink green tea, can also reduce the number of radiation hazards.
Q: Does the computer not turn on the power supply only?
There is radiation in the current flow in the wire, but the radiation is relatively small. So do not boot will have radiation, but the radiation is relatively small.
Q: Telecom fiber cat has wireless Internet access, but my family has a baby, afraid of radiation, and I only use the Internet cable, wireless Internet access is not on. I would like to ask, is not I do not have wireless Internet access, although the home has a wireless Internet access signal, but the basic no human radiation?
Wireless open, there is radiation, he off just fine, into the management of broadband cat interface, the wireless function off just fine, so there is no signal, and now, everywhere is the radiation, in fact, prevent you The point of the cat's radiation is also meaningless Do not say anything else, that your home must have a cell phone signal it, there is a certain signal of mobile phone radiation, this can not be avoided, say more common, there are electricity. The There must be radiation, the electrical end will have a certain degree of radiation, and the socket interface at the radiation is not small
Q: Can pregnant women sleep on the computer?
Computer host, monitor, mouse, keyboard and the surrounding equipment will produce radiation, eyes can not see, hands touch. According to scientific research shows that: computer-generated low-frequency electromagnetic radiation on the human body caused by the damage is hidden, the accumulation of people often (long-term) in the ultra-strong computer low-frequency electromagnetic radiation environment using the computer, leading to dizziness, headache, Tinnitus, brain cancer, breast cancer, blood pressure, abnormal blood pressure, chest tightness, bradycardia, bradycardia, heart failure, loss of vision, loss of appetite, fatigue, memory loss, some people hair loss, leukopenia, immunity, cataract, leukemia, , Heart rate reduction, sinus heart rate, male sperm quality, some women menstrual disorders, maternal abortion, stillbirth, fetal malformations, reproductive lesions, genetic lesions, cancer and other terrible diseases. People in the operation of the computer, the face will absorb a lot of electromagnetic radiation particles, often radiation will appear facial rash. A person working on a computer for five hours, the computer produces low-frequency radiation damage to the human body, the equivalent of a day of life loss.
Q: What are the rumors about radiation?
To give an exaggerated example, even if people put into the subway, the train station used X-ray security device, to scan about 100 times to reach a chest radiation received by the dose. However, pregnant women and children still try to avoid the above situation, although the small dose of security, may also cause some radiation on the body. Rumors of four home appliances radiation induced gene mutation? Some people worry that home appliances radiation will have an impact on human health, and even claims that home appliances radiation not only induced gene mutation, to promote the production of mutant cells, but also disrupt the secretion of hormones, affecting the central nervous system, leading to neurasthenia. But in general, each home appliance has a fixed operating frequency of the national standard (marked in the product specification). In the same work intensity, the higher the frequency, the greater the radiation effect on the human body. Microwave oven At the start of the door at the maximum electromagnetic radiation, but the microwave can absorb the electromagnetic waves, cut off the electromagnetic waves, even if the cooking is not too close.
Q: Will the electromagnetic induction heating equipment will have electromagnetic radiation on the human body do you have physical damage to the operator?
3, the frequency and principle of industrial electromagnetic heating and household appliances are basically the same, and now, household induction cooker has entered thousands of households, security is no doubt, in fact, the effective distance of induction cooker magnetic field is very short, only 3cm within the iron There is a role, we may wish to be a simple and effective test, your home cooker pot bottom slightly improved even 1cm, the bottom of the electromagnetic induction on the rapid decay, and our industrial use of electromagnetic heating, the coil from the operating workers are more than 1500mm, The danger is completely negligible.
Q: Radiation of electrical radiation
Speaking of household appliances radiation, people will be on the computer, television and other large appliances have been vigilant, but can not think of hair dryer such a small appliance radiation greater. According to the measurement, the general household 1000W hair dryer, radiation value of up to 350mG or so (mG: millis is the magnetic field strength unit), far higher than the TV (about 45mG) and computer monitors (100mG) radiation value. Hair dryer in the open and closed when the radiation is the largest, so the switch as far as possible away from the head; use as far as possible with the head to keep vertical; but also to avoid prolonged use.
Q: Laser light is generated by electromagnetic radiation or ionizing radiation
Just some marble or tiles may have a trace of ionizing radiation.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords