Quick Details of 4V Series Solenoid Valve for Water, Gas, Oil, Air
Standard or Nonstandard: | Standard, | Structure: | Pilot | Pressure: | Medium Pressure |
Power: | Solenoid | Material: | Brass | Temperature of Media: | Medium Temperature |
Media: | Water, Gas, Oil, Air | Port Size: | M5 M6 1/8" 3/16" 1/4" 5/16" 3/8" 1/2" 3/4" 1" 2" | Place of Origin: | China |
Model Number: | 2V 3V 4V SY UW US SLP ZS 2S 2L | Brand Name: | LQ | pneumatic: | valves |
Packaging & Delivery of 4V Series Solenoid Valve for Water, Gas, Oil, Air
Packaging Detail: | inner box carton pallet |
Delivery Detail: | 7-10 days |
Specifications of 4V Series Solenoid Valve for Water, Gas, Oil, Air
1.Acting Type: direct acting
2.Coil Type: DIN type/ Flyling lead
3.Protective Class:IP65(DIN40050)
4.100% test
Usage of 4V Series Solenoid Valve for Water, Gas, Oil, Air
4V series directional solenoid valves have 5/2 and 5/3 types, size from M5 to 1/2", while 5/2 types have single solenoid type and double solenoid type, Single solenlid valves is repositioned by the spring, and the double solenoid vavle is repositioned by the coil. 5/3 type solenoid valve can make the cylinder piston stop at any position.
Specification of 4v Series Solenoid Valve (2 Position 5 port single control)
Model | 4V110-M5 | 4V110-06 | 4V210-06 | 4V210-08 | 4V310-08 | 4V310-10 | 4V410-15 |
Working Medium | Clean Air (40 Micrometer Filtration) | ||||||
Ways | 2 Position 5 Port | ||||||
Acting Type | Direct Acting | ||||||
Joint Size | Import=M5
Export=M5 Exhaust=M5
| Import=1/8
Export=1/8 Exhaust=1/8
| Import=1/4
Export=1/4 Exhaust=1/8
| Import=1/4
Export=1/4 Exhaust=1/4
| Import=3/8
Export=3/8 Exhaust=1/4
| Import=1/2
Export=1/2 Exhaust=1/2
| |
Sectional Area | 5.5mm2 (CV=0.31) | 12mm2 (CV=0.67) | 14mm2 (CV=0.78) | 16mm2 (CV=0.89) | 25mm2 (CV=1.39) | 30mm2 (CV=1.67) | 50mm2 (CV=2.79) |
Working Pressure | 0.15-0.9Mpa | ||||||
Guarantee Pressure | 1.2Mpa | ||||||
Working Temperature | -5-60°C | ||||||
Voltage Range | -15%-10% | ||||||
Heat Resistant Grade | B | ||||||
Protective Class | IP65(DIN40050) | ||||||
Coil Type | DIN Type, Flying Leads | ||||||
Max Acting Frequency | 5 Times/s | 4 Times/s | 3 Times/s |
- Q: How does solenoid valve power supply?
- One is the 220 volt power line of the solenoid valve, and the other is the signal line of the valve position switch.
- Q: How is the electromagnetic valve linked with the pump?
- Friends, if you want to pump and solenoid valve linkage, then the electromagnetic valve must be installed in the water outlet pipeline of the pump
- Q: What are the several points of the electromagnetic valve?
- Therefore, the two bit three pass refers to the spool has two positions, 3 ports of the solenoid valve
- Q: Gas water heater solenoid valve when the good and bad?
- if you can't pull it, it might be an old battery or a problem with the ignition.
- Q: How to maintain the electromagnetic valve?
- Should clean the large valve inside and outside the armature and suction surface dirt.
- Q: Which part of the washing machine is in the washing machine?
- Solenoid valve is used to control the automation of the fluid basic components, belonging to the actuator; not limited to hydraulic, pneumatic
- Q: Duty cycle type solenoid valve operating principle
- When the internal ground when the current through the solenoid valve, control valve to start Z.
- Q: What's the difference between the pressure free solenoid valve and the pressure solenoid valve?
- electromagnetic valve (Electromagnetic valve) is an electromagnetic control of industrial equipment, is used to control the automation of the basic components of the fluid, is an actuator, not limited to hydraulic, pneumatic
- Q: Solenoid valve does not use relays, can automatically work
- Automatic work needs to meet the following conditions:
- Q: The reason to the solenoid valve coil burned out the
- The rated voltage is not consistent with the supply voltage. When the supply voltage is higher than the rated voltage of the coil, the main magnetic flux increases, resulting in the increase of the current in the coil, the core loss will increase, so that the iron core heating, and thus easily burn the coil.
1. Manufacturer Overview
Location | Shanghai, China |
Year Established | 1997 |
Annual Output Value | Above US$ 0.5 Million |
Main Markets | Europe, North and South America, Africa and the Middle East and Southeast Asia . |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai |
Export Percentage | 40% |
No.of Employees in Trade Department | 100People |
Language Spoken: | English; Chinese; Spain; Alabic |
b) Factory Information | |
Factory Size: | Above 6,000 square meters |
No. of Production Lines | 4 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | Average |
Send your message to us
4V Series Solenoid Valve for Water, Gas, Oil, Air
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches