• WSM-315 400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine System 1
  • WSM-315 400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine System 2
WSM-315 400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine

WSM-315 400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

WSM-315/400 IGBT Series Inverter DC Pulse Argon Arc Welding Machine

Quick Details

· Condition: New

· Place of Origin: China (Mainland)

· Brand Name: OEM

· Model Number: WSM-315I WSM-400I

· Pilot Arc Current: 10-315 10-400

· Rated Duty Cycle: 60%

· Dimensions: 566*290*500

· Usage: Welding

· Voltage: 380V

· Certification: ISO9001

· certificate: ISO9001:2008

· Authentication: CCC

Characteristic

1. Starting arc by high frequency oscillation when argon arc welding, reliability, steady function.

2. Independent control pulse frequency and duty cycle.

3. Faster response after short circuit in welding rod and workpiece during melt drip procedure.

4. Automatic control starting arc and end arc makes arc steady.

5. One machine with several purposes.

Technical Parameter

Model

WSM-315IGBT

WSM-400IGBT

Rated Input Voltage(V)

3~380

3~380

No-Load Voltage(V)

54

54

Rated Input Power(kV/A)

12.8

18.6

Output Current Range(A)

5-315

5-400

Rated Welding Voltage (V)

32.6/22.6

36/26

Rated Duty Cycle (%)

60

60

No-Load Loss(W)

100

100

Efficiency (%)

85

85

Pulse Frequency(Low) Hz

0.25-2.5

0.25-25

Pulse Frequency(Middle) Hz

25-250

25-250

Current Up-Slope Time(S)

0-10

0-10

Current Down-Slope Time(S)

0-10

0-10

Background Current(A)

5-315

5-400

Starting Arc Current(A)

5-315

5-400

Ending Arc Current(A) Time (S)

5-315

5-400

Post Flow

0-10

0-10

Duty Cycle%

0-10

0-10

External Size L*W*H(mm)

566*290*500

566*290*500

Weight (kg)

33

37


Q:Excuse me: reallink argon arc welding field effect transistor K2698 can use IRFP460 substitution?
Can completely replace IRFP460, voltage and K2698 equal 500 volts, the current is slightly larger, 20 g under normal temperature, other technical parameters are the same
Q:Reallink Christie and argon arc welding machine which is good, what are the advantages
Christie and Ruiling is not the 'brothers alone' as far as I know: reallink is the founder of Mr. Qiu Guang, then (now Christie's boss) A and Qiu Guang cooperation, A money, Qiu light technology. After separation, was also playing a lawsuit, finally to Qiu Guang reallink. Behind the A made a new brand of Christie
Q:What's the difference between WSM argon arc welding machine and TIG argon arc welding machine?
WSM is DC pulse argon arc welding, which has more pulse function than TIG.
Q:Christie argon arc welding machine is good
Can I use the beacon, ulite, personal feeling can
Q:The length of wire on the two side of arc welding machine shall not be more than several meters
The length of the wire is 100 meters. But the welder must use BX1 or BX3, ZX5 and so on. That is to say, the output voltage should be higher. General 75-80V is easy to use.
Q:What accessories does argon arc welding machine need?
An argon arc welding machine, with parts of the manual, wire, welding wire, welding torch mouth (copper mouth and porcelain mouth), tungsten pole, and the need to buy an argon gas pipe, a length of its own, argon meter, argon cylinder one.Argon arc welding is a kind of welding technology using argon gas as protective gas. Also called argon gas shielded welding. That is, argon shielded gas is applied around the arc welding, and the air is separated from the welding zone to prevent the oxidation of the welding zone.
Q:ZX7 inverter type DC arc welding machine, when the welding current is 150A, how much power can it have?
1 when the welding current is 150A.2. If the maximum power of ZX7 500 inverter type DC arc welding machine should be 25 thousand volt ampere, we can check exactly how much.3, in fact, kilovolt ampere and kilowatt should be about the same meaning, you should understand.4, according to the current you use, you can calculate the power consumption of the welding machine.5, you can do a rough calculation, (25 / 500) * current you are using now.6, if you use the 150 current, now (25 / 500) * 150=7.5 (kW / h).
Q:How many volts are there in welding line when argon arc welding machine is welding?
No load voltage: when the welding machine is energized, but no welding operation (no arc), the voltage on the output terminal of the welder is usually between 60~80V;Load voltage: of course, the output voltage of the welder when there is arc (with current or pressure drop), or the voltage between the weldment and the weldment is usually half or less than that of the no-load (with respect to the current);Working voltage: more general, can refer to the power supply voltage, load, output voltage and welding arc voltage of welding machine.
Q:What's the difference between pulsed direct current welding machine and inverter argon arc welding machine?
Pulsed DC electric welder also called pulse TIG welding machine, mainly used for welding of high quality, high requirements, generally used for thin plate welding, the workpiece deformation is relatively small, while at work, there are two kinds of current state, namely the peak current and the low value of current, can be adjusted respectively two current alternating frequency and duty cycle, now generally is the inverter pulse argon arc welding machineInverter argon arc direct current welder is the basic state of pulsed argon arc welding machine. When working, there is only a constant welding current,The above two kinds of welding machine generally has a slow rise and slow drop time time, slow rise time is the arc when welding current from the minimum current is increased to the set welding current time, and then enter the set constant welding current welding, arc current, welding current from the set gradually reduced to the current time is slow down time, then stop welding
Q:When argon arc welding, the old arc is what causes the current to be smaller, so the arc begins when the gear is turned up!
Broken arc welding voltage is too low to maintain arc.The current is small, the voltage is high, and the arc can be maintained. When the current is high, the voltage drops, and the arc is broken when it is too low.Generally speaking, the power shortage of the welder.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords