• Round Type Wiring Duct System 1
Round Type Wiring Duct

Round Type Wiring Duct

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
2000 Meters m
Supply Capability:
20.000 Meters per Day m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Comply with CE,SGS

 

2.Made fof  PVC,2500V insulation and heat-resistingup tp 85 degrees

 

3.All colors can be made

 

4.Any size you want

 

5.Round type wiring duct

 

6.Combustion proof and  Durable

 

7.tape for permanent stick

 

 

Cable Ducts :

 

Material : PVC

 

Instruction :made up of duct bottom and lid , with two out-holes designed at the bottom

 

Usage :Home telephone wires ,DGT Wiring,Disaster Prevention ,burglarproof,Monitoring System the wire

 

Feature :Sermicircle design of the norch cover makes the product not to stumble the passer when used on floor,also easier to be carried and let the trolley pass

 

Certificate :CE , ISO9001,SGS

 

Size:

ITEM NO.

outer width

inner width

outer height

inner height

K-RTD-2

20

8

6

4

mm

mm

mm

mm

K-RTD-3

30

11

8

6

mm

mm

mm

mm

K-RTD-4

40

16

9.5

7

mm

mm

mm

mm

K-RTD-5

50

20

11

8

mm

mm

mm

mm

K-RTD-6

60

30

13

9

mm

mm

mm

mm

K-RTD-7

70

40

15

10

mm

mm

mm

mm

K-RTD-9

90

45

19

15

mm

mm

mm

mm

K-RTD-120

120

70

25

21

mm

mm

mm

mm

 

Q:Wires and natural gas pipes buried in the same trunking have no effect
Generally do not seem to, his section is very small, do not need to break the head
Q:I ask: I open the slot, take a good line, leaving the tank and the wall mud flat, and asked the need for the proportion of cement and sand is how much? What is the degree of water What type of cement? Do not appear after the mud can not scratch the wall, drop the problem. Thank you more
Your own power is to support the back line, the wire is extended
Q:Is it possible to lay the weak floor trunks with floor heating? The specific approach is? Such as title
According to the current number of estimates, know the power, it is not difficult to know the current bar commonly used in the square of the square per square millimeter is 5A, more than ten square you reference the circuit breaker instructions, there is a table (circuit breaker selection and nominal wire cut Area, I think you should understand it, such as 2.5 square is 20A of the circuit breaker, it will be able to withstand 20A current) three-phase power general security per kilowatt 2A estimate
Q:Just finished finishing, the wall trough cracking, very fine cracks
In the final analysis, or intelligent switch design problems, the real design of a good smart switch is not required at both ends of the lamp and then any resistance or capacitor accessories
Q:Customer requirements in the distribution cabinet door must be installed wiring groove, how to fix on the above? Solid point of the double-sided adhesive is not the total out there is no more strong glue more fixed three anti-paint and PVC plastic or other way more
. not the medium voltage power cable marked "8.7 / 10kV and 8.7 / 15kV", but depends on the manufacturer is 10kV insulation requirements for production, or by 15kV insulation production; this is not a thing of the two . the power cable nominal 6 / 10kV, refers to the cable can be used in the phase voltage of 6kV, line voltage of 10kV system, which is the so-called 10kV system in the normal cable; but in many cases , Phase, line voltage may be increased, such as 10kV system is a neutral point is not grounded system, when the single phase ground will cause phase voltage increases, then 6 / 10kV cable can not be used to increase the phase insulation; If the capacitor increases the reactor, the line voltage will rise more than 10kV rating, so then the 6 / 10kV cable is not enough, so only to increase the insulation layer, to increase the line insulation; this has 8.7 / 10kV and 8.7 / 15kV power cable; . in this talk, many people in the procurement of cables, only that their procurement of 10kV cable, and no specific technical requirements, to some manufacturers caused by the opportunity, many manufacturers to reduce insulation, Reduce the diameter, reduce In addition, to select enough to produce qualified, good reputation of large enterprises, although the price may be more expensive, but the quality of protection, I have been to some small manufacturers, you have to pay attention to the safety of the user, And he said two kinds of cable, he only know that 10kV cable, simply can not tell the difference between the two, but dare to give you the manufacture of cables, make products that you play what signs, this product you choose to rest assured? If not other considerations, or do not use some of the poor quality of the product as well.
Q:Strong electric weak tube to take a trunking problem big why
Strong electric weak casing to take a trunking, bad, will cause interference. And does not meet the specifications. Because the weak trough and strong wire trough spacing should be ≥ 300mm. Reason: strong power at work, especially in high-power appliances in use, the interference of the signal line is obvious, especially for closed-circuit television lines. Signal lines (telephone lines, closed-circuit television lines, network cable) and other weak wires and strong electric wire is strictly prohibited "common slot co-management", weak wire trough and strong wire spacing should be ≥ 300mm.
Q:What is the difference between a trough wiring and a pipe
Specification for Steel Cable Tray Engineering (CECS31: 2006) Section 3.6.2 specifies the minimum allowable thickness of the bridge plate in all cases
Q:When the interior decoration, the roof on the alignment do not casing ah? At that time the slot is very small, the electrical preparation of bare wire, okay? I have no ceiling
The center of the circle is located on the extension of the linear current, and the linear current does not generate a magnetic field at that point
Q:Will the two 16 square copper wire with what specifications of the trunking
YJV: XLPE insulated PVC sheathed power cable vv is a copper cable 4 * 240 + 1 * 120 is a five-core cable with PE
Q:The contents of the VAT invoice for the other party: Ming bit alignment system materials, a group. And my unit is the entry slot, switches, etc., how should the invoice should be opened "
. the wire is the conduction current of the wire. . the cable is used to transmit (magnetic) energy, information and the realization of electromagnetic energy conversion wire products. . the wire is made of one or several soft wires, the outer package to soft and soft layer; cable is composed of one or several insulated package wire, outside the package to the metal or rubber made of tough outer layer. Cables and wires are generally made up of three parts: the core wire, the insulating sheath, and the protective sheath.
Our company is professional in producing and selling plastic wiring ducts and other kinds of plastic fittings for electric appliances. Through testing by Shanghai Electric Quality Central, all products meet CE standards. We will offer high quality, honesty, speed delivery and good services.

1. Manufacturer Overview

Location Zhejiang,China
Year Established 1999
Annual Output Value
Main Markets North America
South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Company Certifications ISO 9001:2008 ;SGS

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage 41% - 50%
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size: Below 1,000 square meters
No. of Production Lines
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords