Case: Round aluminum oil-filled and sealed case.

AC film capacitors for general purpose applications (e.g. AC filters with harmonic frequencies exceeding 60 Hz), as well as for lighting and motor run applications. For the latter, AC capacitors are used in conjunction with asynchronous motors on single-phase mains supplies. They are designed for 50 or 60 Hz systems.


Applications:Asynchronous motors、Air conditioning、Domestic appliances、Compressors/pumps/garage、door openers、 Awning drives、 Heat pumps ets.



****Specifications****
Standard temperature
-25℃ ~ +85℃
Voltages Ratings
250V - 500V AC
Capacitance Range
1-120 uF
Applicable Standard
IEC60252-1:2011,GB/T3667.1-2005.UL810、EN60252-1:2011
Size


φD±1mm
40
45
50
55
65
H±2mm
55-75
75-100
85-100
100-125
100-125



Q:How does the capacitor work? What does it do?
The other is the signal filter, that is, the case of alternating current, but also in the AC electrode polarity changes in the process of continuous charge and discharge, in order to AC, if not the capacitance of the two sheds with the amount of change, no matter how the AC can not pass.
Q:Does anyone know the difference between the stray inductance of the capacitor and the parasitic inductance?
With the increase in stray inductance, IGBT turn-on loss will be reduced, the diode loss will increase. Stray inductance may also cause oscillations, such as oscillations caused by current mutations, which may result in limited device use due to EMI or overvoltage limits.
Q:How to judge the capacitor is good or bad?
10pF below the fixed capacitor capacity is too small, with a multimeter to measure, only qualitative check whether there is leakage, internal short circuit or breakdown phenomenon.
Q:What is the relationship between capacitance and voltage?
The larger the capacity of the capacitor, the larger the voltage, the smaller the capacity (uF). Since q = Cu, q is the current charge number of the capacitor, which is substantially proportional to the volume of the capacitor
Q:On the ground resistance, what role the capacitor
Decoupling: The capacitor used in the decoupling circuit is called the decoupling capacitor. This capacitor circuit is used in the DC voltage supply circuit of the multi-stage amplifier. The decoupling capacitor eliminates the harmful low frequency cross-connection between the amplifiers.
Q:Use capacitance to do transformer how to calculate
Similarly, we can also 5W / 65V bulb and 1uF capacitor series connected to the 220V / 50Hz AC, the bulb will be lit, and will not be burned. Because the 5W / 65V bulb operating current is also about 70mA. Therefore, the capacitor buck is actually using capacitive current limiting. While the capacitor actually functions as a limiting current and dynamically distributes the voltage across the capacitor and the load.
Q:Why some Y capacitor is very small, and some Y capacitor is very large?
In line between the line of fire and zero line suppression capacitor, commonly known as X capacitance. As the location of the capacitor connection is also more critical, the same need to meet the relevant safety standards. X capacitance is also one of the safety capacitors. According to the actual needs, the capacitance value of the X capacitor is larger than the capacitance of the Y capacitor. However, it is necessary to connect a safety resistor in parallel with the X capacitor to prevent the charging and discharging of the power supply line.
Q:Capacitance can pass high frequency resistance low frequency principle
The capacitor has a charge and discharge time problem. When the positive half of the AC, to the capacitor charging moment, the circuit is a current flow, the equivalent of the channel, once the capacitor is charged, the circuit will not flow through, the equivalent of open circuit.
Q:Low voltage capacitor voltage 0.45 and 0.4 What is the difference between usage
0.45 and 0.4 capacitors are capacitors that rated the line voltage of 0.45kV and 0.4kV; they are suitable for 380V voltage systems, the difference lies in their pressure rating;
Q:What is the difference between the power capacitor and the complement?
Wiring, three-phase complementary capacitor has three terminals, respectively (A, B, C) sub-capacitor has four terminals, respectively, then

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords