• Plug with Battery Backup for Home Used 400va CPU Control Offline UPS System 1
Plug with Battery Backup for Home Used 400va CPU Control Offline UPS

Plug with Battery Backup for Home Used 400va CPU Control Offline UPS

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
500 Pieces pc
Supply Capability:
6000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
  • Phase: Single Phase

  • Protection: Full protection

  • Weight: 3-5kgs

  • Output Voltage: 120 VAC or 220/230/240VAC

  • Type: Standby

  • Application: computer printer fax TV

  • Model: Plug with battery backup 400va cpu control offline ups

  • Voltage Range: 90~145 VAC or 170/270 VAC

  • Frequency: 50Hz or 60Hz

  • P.F.: 0.5

 

 

Specificatons 

1.400va / 200w, 12vdc

2.288X125X89 mm

3.Multifunction ups plug

4.ISO9001

 



 

Features

Ease-of-use:The plug-and-play functionality of the product allows you to start backing up your equipment the moment you take the unit out of the box. Gain automatic integration with Windows, Mac and Linux with a simple connection to a USB port.

 

Modern design:The sleek design of the product allows you to display it alongside your high-tech equipment for a sophisticated look. This unit can also be wall or desk mounted for additional space savings.

 

Premium protection:The high-efficiency design of the product provides premium power protection for up to 10 devices, including those using data lines.

Q:Emerson UPS power supply is mainly frequency machine or high frequency machine
Ibid. The The Haha. The The South China Emerson agency reported,
Q:Power supply Merlin Geran country
French brand, the rest of the world has a number of factories, is now a French Schneider Electric's a brand, UPS leader APC has also been acquired by France Schneider, APC and Merlin Gerin are Schneider Electric's product brand, we used to APC, Now go to Schneider tube!
Q:Petrochemical industry, two UPS dual-machine hot backup power supply for the instrument, this part of the load how to calculate the need to account for the total capacity of the load?
UPS for the instrument power supply need to join the load!
Q:Brother for the first time to play ups would like to ask about this connection is wrong. I am connected to the uninterrupted power supply on the spark, what is the problem ah?
This can not be seen, you use a multimeter to determine whether the battery voltage is consistent with the design.
Q:Such as the title, the best recommended a few more choice, thank you!
A total of 3KVA need to host a, battery cabinet 8 cabinet two, 100AH battery 16. The total price of 14000-20000 between it, look at your choice of host and battery brand.
Q:There is no installation of lightning protection device UPS, can be said that there is no lightning protection function, only the city power grid over-voltage or very small stray current play a role in power purification and protection. When the lightning coming, it is first badly damaged; built-in lightning protection device UPS, can not improve its own, and to protect other equipment from lightning damage; from the overhead power line and signal line intrusion Leak over voltage and induced lightning over voltage, is the main cause of damage to the intelligent UPS. Therefore, to strengthen the UPS power supply lightning protection measures is necessary, but also has important practical significance.
Before saying that UPS power lightning, we have to look at the UPS work environment: 1, whether the electricity terminal has lightning protection measures; 2, whether the UPS itself or near the ground; If the mains households have installed T1-level surge protector, UPS front-end installation of T2-class surge protector, it is recommended that In not less than 20KA, Up is not greater than 1.8kV, UPS output T2 level, 10KA, Up not more than 1.25kV; If the electricity is not installed T1-level surge protector, UPS front-end installation of T1-level surge protector, Iimp recommended not less than 12.5KA, Up is not greater than 2.0kV, UPS output installed T2 level, Less than 10KA, Up is not more than 1.25kV; There should be a grounding point near the UPS and ground repeatedly with the incoming power ground. The grounding resistance should not be greater than 1 ohm.
Q:UPS power supply alarm, may be normal power supply, how should deal with?
Fault alarm, please contact the dealer to deal with, the warranty period can be free maintenance
Q:I would like to do waste heat power generation project, DC screen installed in the first floor of the high-pressure room, UPS installed in the third floor of the control room, if the normal power failure, UPS will supply the computer system, DC battery is not inside the battery power supply ah? Is the UPS and DC screen a common battery?
2, the principle is different; DC screen is the rectifier rectifier for the external load power supply; UPS principle is the first AC rectifier for the DC, and then through the inverter unit, the DC inverter AC power supply for the external load. Both in the mains failure, are by the battery pack external power supply. DC screen debugging, connected to the AC power supply test AC dual power switching device is working properly, dual power switch device under the port voltage is normal. After the AC part of the test is normal, close the AC module of the charging module in turn to observe whether the module starts normally and measure the module output voltage and polarity. After the charging module starts normally and the output voltage and polarity are correct, turn on the battery switch and the bus switch to measure whether the voltage, polarity and polarity of the battery switch are correct, and observe whether the voltage meter is in the direction. turn. UPS (Uninterruptible Power System), that is, uninterruptible power supply, is the battery (mostly lead-acid maintenance-free battery) connected with the host, through the host inverter and other modules to convert DC power into the main system equipment The Mainly used for a single computer, computer network systems or other power electronic equipment such as solenoid valves, pressure transmitters, etc. to provide a stable, uninterrupted power supply. When the mains input is normal, the UPS will be powered by the mains supply to the load, this time the UPS is an AC mains regulator, and it also charge the battery to the machine; when the electricity interruption (accident power failure) , The UPS immediately to the battery DC power, through the inverter zero switching method to continue to supply 220V AC load, so that the load to maintain normal work and protect the load soft, the hardware is not damaged. UPS equipment is usually too high voltage or voltage can provide protection.
Q:Technical indicators
What is it? UPS is an uninterruptible power supply (Uninterruptible Power Supply) in English abbreviation, is able to provide a sustained, stable, uninterrupted power supply of important external equipment. In principle, UPS is a set of digital and analog circuits, automatic control inverter and maintenance-free storage devices in one of the power electronic equipment; Functionally speaking, UPS can be abnormal in the mains, the effective purification of electricity; can also be a sudden interruption in the city power for a certain period of time to the computer and other equipment power supply, so you can have plenty of time to cope with; From the use of information society, UPS is widely used in information collection, transmission, processing, storage to the application of all aspects, the importance of information applications with the increasing importance of increasing.
Q:Will UPS burn in those cases? Is the mains voltage exceeding the input voltage range? Or because the load percentage is too large?
Large brand of UPS beyond the input voltage range will not burn, with a large percentage of load will not burn. Because UPS has a self-protection function. Voltage, load out of range UPS does not work. 90-270 access 380UPS does not work. Will not burn. Unless you sell fake. General burn is the aging of components, or internal dust, static and other UPS internal reasons. Cottage UPS I do not know. 380 input with 220 electricity will not burn, the voltage is too low when the battery-powered UPS work properly.
Our products are accredited with CE (EMC and LVD directives) and RoHS standards. We are of experienced engineers with Master Degree, who are committed to provide technical support and after-sales service to our customers around the world.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2004
Annual Output Value US$10 Million - US$50 Million
Main Markets Oceania 1.00%
Mid East 10.00%
Eastern Asia 5.00%
Western Europe 10.00%
Northern Europe 1.00%
Southern Europe 1.00%
South Asia 5.00%
North America 1.00%
South America 1.00%
Eastern Europe 20.00%
Southeast Asia 30.00%
Africa 15.00%
Company Certifications copyright Certificate; RoHS certificate; LVD certificate; EMC certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shekou Port,Yantian Port,Huangang Port
Export Percentage 91% - 100%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese, Russian, Italian
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range High and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords