Online UPS 60KVA
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Online UPS 20-80KVA
The HF33 20-80K series UPS is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. HF33 20-80K series UPS provide customers safe and sound power supply.
Excellent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter
larger than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can
help to increase the protection level in industrial environment and safeguard the ups security when operation in bad environment.
N+X parallel redundancy (battery share in the parallel mode
The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the
system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of redundant UPS
in the system. The bigger the number of X is, the higher the reliability of the system.The advanced controlling strategy decrease customer's investment by sharing battery group in the parallel redundancy mode.
Intelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter, and provide
the optimum charging modes in different environment, types and amounts of cells, and the using condition of the battery. The
scientific charging mode extends the battery's lifetime. The optional addition to charging units shortens battery charging time.
Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.
Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization of remote
management and monitoring.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability.
Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the power loss of UPS.Th factor that the technology of IGBT FM intelligent rectifier and inverter is used , the input power factor is as high as 0.99, and
the input current harmonic wave is as low as 3%,which makes the output voltage electric property more extraordinary.Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1 minute in load of 125-150%. It also has the output short circuit protection capability.
MODEL | HF 3320L | HF 3330L | HF 3340L | HF 3360L | HF 3380L |
Rated Power | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW |
INPUT | |||||
Voltage | 380/400/415VAC(-45%~+25%) | ||||
Frequency | 50/60Hz | ||||
Phase | 3Ph+N+G | ||||
Power Factor | >0.99 | ||||
BYPASS | |||||
Voltage | 380/400/415VAC(-15%~+15%) | ||||
Phase | 3Ph+N | ||||
Frequency | 50/60Hz | ||||
Overload Capability | <150%, normally running | ||||
BATTERY | |||||
Battery Voltage | 336/360/384VDC | ||||
Charging Current | 1-10A(setting by battery capacity) | ||||
OUTPUT | |||||
Phase | 3Ph+N | ||||
Voltage | 380/400/415VAC±1% | ||||
Frequency | 50/60Hz | ||||
Power Factor | 0.8 | ||||
THD | <2%(linear load); <4%(non-linear load) | ||||
Overload Capability | <105% normally running;105%-125% 10min; 125%-150% 1min; 150% 1ms | ||||
Waveform | Pure Sine Wave | ||||
Transfer Time | <10ms | ||||
SYSTEM | |||||
Efficiency | >93% | ||||
Cooling | Fan Cooling | ||||
Communication Interface | RS232,RS485,SNMP card, Dry Contact | ||||
Display | LCD+LED | ||||
Operating Temperature | 0-40℃ | ||||
Humidity | 0-95% non-condensing | ||||
Altitude | <4000m(derated 1% per 100m above 2000m) | ||||
Noise Level | <50dB | <60dB | <65dB | ||
Protection Level | IP20 | ||||
Storage Temperature | -25℃~55℃ | ||||
Dimension(W×D×H mm) | 420×646×956 | 470×714×1160 | 600×800×1850 | ||
Weight(Kg) | 80 | 120 | 120 | 282 | 306 |
Specification is subject to change without prior notice. |
- Q:What is the UPS power supply and why does the front of the switch total trip?
- General settings for current leakage protection device 60MA, larger 300MA, is very easy to cause the error protection of leakage protection. Therefore, the general UPS front is not install leakage protection so that UPS itself is not with leakage protection.
- Q:UPS's detailed knowledge?
- 500VAUPS how long is the backup time? (1) and 500VA adopt 12V7AH battery section. When an ordinary PC computer, when the backup time is about 7 minutes, enough users according to the normal procedure exit shutdown, and protect the data will not be lost; (2), UPS continuous supply of length of time depends on the size of the load. Refer to the "discharge curve" of the product manual".
- Q:The server is the highest rated power power power 500W power 270W 400W actual computer hardware over time with 12 hard disk so 300W with an optical transceiver to 320W display to unplug the server after power failure in the company of our own and run the web site to prevent power which can maintain 8 hours of running the best server is the 12 hour UPS brand does not need to be too good not to use enough often cut occasionally can be added:
- You still have to use the power of about 320 1KVA UPS, but also with the best use of the battery online, how much more than the backup, you can match Burke HS-1K is this: http://www.gdbaykee /flash/sort082/sort0103/UPS_EPS15.html UPS. But in general a long time, 8 hours to many batteries, a lot of money, are used with the generator UPS to the long time the general people power.
- Q:How to fit a battery pack for a UPS power supply
- Nominal capacity of battery pack = I maximum /CWork out the nominal capacity of the battery.Because the lowest critical voltage E - critical value of the battery, it will lead to the requirements of the battery capacity is too large for the situation ah. According to the experience of using the current, can be calculated as the actual battery capacity ah:Actual battery capacity (AH) = nominal capacity of battery pack *0.8Time and discharge rate C
- Q:I know that UPS is the uninterruptible power supply devices, but EPS seems to be uninterrupted power supply, the difference between the two please master. In addition, other uninterruptible power supply equipment and emergency security system? The most important application in what aspects in the city?
- UPS is online, failure can timely alarm, and power backup protection, the user can grasp the fault and troubleshooting, will not cause a greater loss of the accident. While EPS is offline use, is the last line of power supply, so the reliability design is more demanding, not simply as the backup UPS, otherwise put off. If the importance of EPS EPS in power failure, not through the emergency power supply battery, EPS as decoration, the consequences will be unbearable to contemplate.
- Q:What is UPS/EPS?
- The UPS is used as a power supply to optimize the power supply of the load equipment and provide protection after power failure, so that the equipment will not cause data loss or other power failures due to power failure.
- Q:UPS power sounds, what's the matter?
- The reasons are as follows:The machine itself has a certain noise, clean environment, maintenance of good noise points. If there is alarm, there are many cases, after the power failure, the battery power supply, voltage instability, resulting in battery power, as well as machine failure, there will be an alarm.
- Q:UPS power how to distinguish between the marking machine and the long machine, what are the criteria, or industry rules?
- UPS power is generally divided into long machine and machine parts, machine must be external battery (with a battery cabinet), standard machine is inside the machine with the battery, the easiest way is: you don't have to take electricity directly with UPS power on, if you can boot is marking machine is not a machine, long open.
- Q:How do you calculate the power supply time of UPS?
- There are usually two ways to calculate a UPS battery:First, constant current mode calculation:According to the principle of conservation of energy, the following formula is used:C = (PL * T) / (Vbat * n * K)The C battery capacity, (Ah) PL uninterruptible power output power (W); T (H) - battery backup time;Vbat battery voltage (Vdc) is UPS battery inverter efficiency (0.90-0.95, according to the selected models).K - battery discharge efficiency (coefficient).
- Q:What server UPS power line?
- If you use the server, it is recommended to buy online, the power conversion time is 0 seconds.The home is generally reserved UPS, in the instant of the power failure, the conversion time is slightly longer than the online type, sometimes it will lead to restart, the brand well, APC, Sendon, Santak.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS 60KVA
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords