Specifications
*high voltage copper cable up 35KV
*high voltage copper cable bear 90 degree
*high voltage copper cable do OEM&ODM service
high voltage copper cable is with following features:
high voltage copper cable use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards / Testing Specications: IEC 60502-1.
xlpe swa pvc cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
The products are mainly complying with iec 60502 standard, also can be produced according to OEM requirements and other standards, such as bs standard, din standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees
high voltage copper cable with following code and specification:
Code Word | AWG or Kcmil | Bare Neutral Messenger | Phase Conductor | Weight | ||
AL.-ALLOY Stranding and wires Dia(mm) | Rated strength(lbs) | Al. Stranding and wires Dia(mm) | XLPE Insulated thickness(mm) | (kg/km) | ||
Minex | 2*6AWG+1*30.58 | 7/1.68 | 1110 | 1/4.11 | 1.14 | 152 |
prawn | 2*4AWG+1*48.69 | 7/2.12 | 1760 | 1/5.19 | 1.14 | 229 |
Shrimp | 2*2AWG+1*77.47 | 7/2.67 | 2800 | 7/2.47 | 1.14 | 354 |
Cammarus | 2*1/0AWG+1*123.3 | 7/3.37 | 4460 | 7/3.12 | 1.52 | 569 |
Dungeness | 2*2/0AWG+1*155.4 | 7/3.78 | 5390 | 7/3.50 | 1.52 | 702 |
Cyclops | 2*3/0awg+1*155.4 | 7/3.78 | 5390 | 19/2.13 | 1.52 | 703 |
Flustra | 2*3/0AWG+1*195.7 | 7/4.25 | 6790 | 19/2.39 | 1.52 | 869 |
LEPAS | 2*4/0AWG+1*246.9 | 7/4.77 | 8560 | 19/2.68 | 1.52 | 1077 |
CRAB | 2*4AWG+1*30.58 | 7/1.68 | 1110 | 7/1.96 | 1.14 | 208 |
SDCRAB | 2*1/0AWG+1*77.47 | 7/2.67 | 2800 | 7/3.12 | 1.52 | 504 |
- Q:The difference between the instrument cable and the low voltage power cable
- Two wire, to ensure that the surrounding quiet, with the ears to determine the clogging range, and then picked up the electric pick
- Q:Is the RVV power cable also called a cable?
- Are you referring to the design of the length of the control cable reserved? Also refers to the number of cable cores reserved? Design the length of the reservation, the number of cores is also reserved.
- Q:In the laying of the time when there is no specific requirements if not and some cable to go the same bridge more
- Shower room installation Note 1: handling, the shower room level easy to make the glass broken, must be vertical and more than two people at the same time handling, and pay attention to avoid collision with the hard objects. Shower room installation Note 2: shower room after the opening of the glass should be placed directly against the wall, placed horizontally or uneven placement may lead to glass damage, resulting in property damage or personal injury. Shower room installation precautions 3: cleaning is strictly prohibited the use of acid, alkali, organic solvents such as chemicals and acid cleaning agents, otherwise it will damage the surface of the product; use of water or neutral detergent on the product surface clean, can not remove the pollution Trace, can be soaked with a small amount of alcohol cleaning cloth to remove stains; shower room installation Note 4: acrylic plate is easy to attach static dust, clean acrylic basin only with cotton cloth dipped in a little soapy water can easily remove the dust Cleaning effect. Shower room installation precautions 5: the use of sealed silicone, silicone rubber should not be coated on the surface of acrylic. If you accidentally painted a little remember not to rush to wipe, so more difficult to remove, should wait until after curing gently peeled out, is strictly prohibited with a hard object scratches, otherwise it will lead to surface damage. After the bottom basin is installed, it should be used after the silica gel is fully cured (silica gel curing time is 24 hours). The above is the relevant shower room installation precautions, hoping to give you in the decoration when the bathroom can play a certain role in helping.
- Q:Instrument cable linked to the card EJB, sjb on behalf of what it means
- Can not, air compressor trachea will be heat, will damage the cable, too many pipelines buried together, after the maintenance will be a lot of trouble.
- Q:We are now the construction site will all BV line to AF? What is the purpose, AF line in the end where the better
- Classification and use of waterproof casing and use of commonly used waterproof casing is divided into two kinds of rigid and flexible
- Q:What is the meaning of kxv in wire and cable?
- Ask you a question, the basement has a power distribution room, high pressure into the wall in the shear wall to stay a few walls through the wall, asked, after the cable through the casing, the cable and how to do between the waterproof treatment? Because now rain, rain water along the casing to the basement irrigation. In the underground garage outside the wall to do a well, the casing around, but still not, because the rain, the wells will be water, the same to the basement irrigation, this place generally how to deal with, it is best to give What is the explanation of what more
- Q:Who provided the more to the sub-gave to whom, thank you for helping
- In the low-voltage circuit below 36V, the cross-sectional area of the conductor is not simply considering the safe current-carrying section, taking into account the line drop caused by the length of the transmission line. The cross-sectional area of the wire must also meet the rated voltage supplied to the load side after the voltage drop
- Q:What is the difference between a KVVR cable and an RVV cable?
- 3 EPDM recycled rubber; EPDM recycled rubber with high and low temperature resistance, anti-aging, high insulation, ozone resistance, anti-erosion and other physical properties, is widely used in wire and cable sheath, hose and other industries to go
- Q:Single-wire and stranded general use, instrument control cable can use a single line?
- The wire is made of one or several soft wires, with a soft jacket; the cable is made of one or several insulated packets, and the outer layer is covered with a tough outer layer of metal or rubber. Cables and wires are generally made up of three parts: the core wire, the insulating sheath, and the protective sheath. Commonly used cable features are as follows: CEF - EPR insulated neoprene jacket, marine flame retardant power cable. CVV - PVC insulated, PVC sheathed marine flame retardant power cable. OVC cable commonly used BV, BX, RV, RVV series of wires, including: BV - copper core PVC insulated wire, long-term allowable temperature 65 ℃, the minimum temperature -15 ℃, working voltage AC 500V, DC 1000V, fixed laying In the room, the outside can be deposited can also be deposited. BX - copper core rubber insulated wire, the maximum temperature of 65 ℃, apply to the room. RV - PVC insulated single-core cord, the maximum temperature of 65 ℃, the lowest temperature -15 ℃, 250V AC voltage, DC 500V, for the internal wiring equipment and equipment. RVV - Copper core PVC insulated and sheathed flexible wire, allowing long-term working temperature of 105 ℃, working voltage AC 500V, DC 1000V, for wet, mechanical protection requirements, often moving and bending occasions.
- Q:For example: WDZB-YJY-3 * 2.5RVSPWEL, etc. Thank you, I am a novice, just enter more
- Change the original or carefully through the Apple accessories, can be
1. Manufacturer Overview |
|
---|---|
Location | Yunnan,China |
Year Established | 2005 |
Annual Output Value | Above US$100 Million |
Main Markets | Southeast Asia 0.3% Africa 0.5 % Domestic Market 99.2% |
Company Certifications | ISO 9001:2000;ISO 9001:2008 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Shenzhen,Guangzhou,Shanghai |
Export Percentage | 21% - 30% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
High Voltage Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Meters m
- Supply Capability:
- 100000 Meters per Month m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords