Specifications

1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate

    220V Single  Phase Variable Frequency Drive 2.2KW

 

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Q:What is the difference between frequency converter and servo driver?
The difference between servomotor and frequency conversion motor:Servo system is a closed-loop control system, the inverter usually works in open-loop control, so in terms of speed and accuracy, and can not be compared to the servo drive.The frequency conversion is only one part of the servo, and the servo controls the closed loop precisely on the basis of frequency conversion so as to achieve better results.
Q:I am in control of the equipment: the same mechanical movement, this needs a motor drive, a frequency converter drive. Now it's due to the mechanical location: buy two units of the same motor. Can you use a converter in parallel to drive it? Please point out! Thank you (frequency converter: the power of Schneider is equal to the sum of two motors)
I suggest you use SIEMENS's 6SE70 model converter (I used this to do a lot of track debugging, it's really easy to use and not easy to go wrong)Communication with the PLC, as long as the Profeibus link on the good, communication and control characters are very good setRemark: a multi motor controlled by a transducer must start and stop at the same time, and the control speed is the same
Q:What role does input and output reactor play?
The input reactor is mainly used to restrain the interference of the higher harmonic produced by the converter to the power supply and other equipments. The output reactor is mainly used to restrain the damage of the higher harmonic caused by the converter.
Q:How much is the motor 90KW and the frequency converter selected?Colleagues suggest 110W?The cost will be higherIs it okay to choose 90KW?
Should be able to, in the design of the inverter in consideration of the corresponding motor power matching. Choose a large capacity, a little waste Oh! Our company choose frequency converter is one-to-one correspondence, did not choose the large capacity.
Q:What are the key points of frequency converter maintenance?
Frequency converter daily patrolDo the inverter daily inspection and inspection work, inspection contents mainly include: ambient temperature, humidity is required, ventilation windows is good; the inverter air inlet and outlet is blocked by dust or too much dust; inverter operation parameter is normal, there is no alarm; cabinet fan the operation is normal; if there is abnormal sound or vibration transducer; capacitor whether overheat.
Q:What are the benefits of installing economizer in industrial enterprises?
Frequency converter is a device that regulates the speed of an electric motor by adjusting the output frequency:1. The frequency converter can only reduce the motor speed by reducing the power supply frequency. The application environment is limited and the automatic control function is not available. It can not be used in many load changing occasions;Have a lot of 2 odd harmonics, frequency converter operation, it will seriously affect other equipment life and efficiency, at the same time use but also affect other precision control of the equipment in the factory, such as computer, automatic control system, monitoring system and so on;3 、 frequency converter serial access to the customer's low-voltage power system, the power supply of the customer security risks.
Q:Which country invented the inverter?
The frequency converter is not developed by a certain individual, it is the research result of a large number of scientific research workers.The background of inverter technology is the wide demand of AC motor stepless speed regulation. The traditional DC speed regulation technology is limited because of its large size and high failure rate.
Q:Heating inverter commissioning steps
And carry on the test run 1. manual operation of the frequency converter panel running stop, observe the motor running process and the frequency converter display window, to see if there is abnormal phenomenon. 2. if the P is started and the over-current protection is stopped in the motor, the acceleration P deceleration time should be reset. The acceleration of the motor during acceleration and deceleration depends on the acceleration torque, while the frequency change rate of the inverter during the start and braking is set by the user. If the inertia of motor or motor load change, speed or deceleration rate according to frequency change preset when possible acceleration torque is not enough, resulting in motor stall, motor speed and the inverter output frequency coordination, thus causing overcurrent or overvoltage. Therefore, it is necessary to set acceleration and deceleration time according to the inertia and load of the motor, so that the frequency change rate of the converter can be coordinated with the speed change rate of the motor.
Q:Schneider 303 4KW frequency converter F 013 trouble shooting method
You see when the alarm is started, or stable operation alarm amount, different times, different analysis
Q:Where is the frequency converter used?
From the industry application: 1, chemical, petroleum, electric power, municipal, mining, cement, water treatment and other industries, the main use of 380V/690V/6-10kv inverter, these industries have a large fan pump power, the original AC operation, high energy consumption, the use of inverter speed regulation can be obtained after large energy saving, so it is the the main users of the main high power converter

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords