50kva - 1500kva Electric Cummins Diesel Generator 6BT5.9G1
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
50kva to 1500kva Electric Generator For Sale
1. Dry type air filter, fuel filter, oil filter
2. 10-hour operation base tank
3. 24V DC start motor and storage battery
50kva - 1500kva Electric Cummins Diesel Generator 6BT5.9G1
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRC30 | 20 | 25 | 24 | 30 | 4B3.9-G | ≤229 | 4 | 3.9 | 102*120 |
GNRC35 | 24 | 30 | 28 | 35 | 4BT3.9-G | ≤214 | 4 | 3.9 | 102*120 |
GNRC56 | 40 | 50 | 45 | 56 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
GNRC63 | 45 | 56 | 50 | 63 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
GNRC70 | 50 | 63 | 56 | 70 | 6BT5.9G1 | ≤215 | 6 | 5.88 | 102*120 |
GNRC106 | 78 | 98 | 85 | 106 | 6BT5.9G | ≤215 | 6 | 5.88 | 102*120 |
GNRC125 | 90 | 113 | 100 | 125 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC150 | 104 | 130 | 120 | 150 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC165 | 120 | 150 | 132 | 165 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC200 | 140 | 175 | 160 | 200 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC225 | 160 | 200 | 180 | 225 | 6CTAA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC275 | 200 | 250 | 220 | 275 | 6LTAA8.9-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC313 | 220 | 275 | 250 | 313 | NTA855-G1A | ≤206 | 6 | 14 | 140*152 |
GNRC350 | 250 | 313 | 275 | 350 | NTA855-G2 | ≤207 | 6 | 14 | 140*152 |
GNRC400 | 280 | 350 | 310 | 400 | NTA855-G4 | ≤208 | 6 | 14 | 140*152 |
GNRC413 | 300 | 375 | 330 | 413 | NTAA855-G7 | ≤206 | 6 | 14 | 140*152 |
GNRC450 | 320 | 400 | 360 | 450 | NTAA855-G7A | ≤206 | 6 | 14 | 140*152 |
GNRC500 | 360 | 450 | 400 | 500 | KTA19-G3 | ≤203 | 6 | 18.9 | 159*159 |
GNRC550 | 400 | 500 | 440 | 550 | KTA19-G4 | ≤203 | 6 | 18.9 | 159*159 |
GNRC605 | 440 | 550 | 484 | 605 | KTAA19-G6 | ≤204 | 6 | 18.9 | 159*159 |
GNRC625 | 450 | 563 | 500 | 625 | KTAA19-G7 | ≤204 | 6 | 18.9 | 159*159 |
GNRC700 | 500 | 625 | 560 | 700 | KTA38-G | ≤206 | 12 | 37.8 | 159*159 |
GNRC712 | 520 | 650 | 570 | 712 | QSK19-G3 | ≤206 | 6 | 19 | 159*159 |
GNRC800 | 580 | 720 | 640 | 800 | KTA38-GA | ≤209 | 12 | 37.8 | 159*159 |
GNRC825 | 600 | 750 | 660 | 825 | KTA38-G2 | ≤210 | 12 | 37.8 | 159*159 |
GNRC888 | 640 | 800 | 710 | 888 | KTA38-G2B | ≤210 | 12 | 37.8 | 159*159 |
GNRC975 | 720 | 900 | 780 | 975 | KTA38-G2A | ≤210 | 12 | 37.8 | 159*159 |
GNRC1075 | 800 | 1000 | 860 | 1075 | KTA38-G5 | ≤202 | 12 | 37.8 | 159*159 |
GNRC1375 | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1375 | 1100 | 1375 | 1310 | 1650 | KTA50-G8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1650 | 1200 | 1500 | 1340 | 1675 | KTA50-GS8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1675 | 1350 | 1688 | 1500 | 1875 | QSK60-G3 | ≤215 | 16 | 60 | 159*159 |
GNRC1875 | 1500 | 1875 | 1650 | 2063 | QSK60-G3 | ≤215 | 16 | 60 | 159*190 |
GNRC2063 | 1600 | 2000 | 1800 | 2250 | QSK60-G4 | ≤215 | 16 | 60 | 159*190 |
Genset Features:
1. Genuine Commins industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9. Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine Cummins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Super Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
- Q:Why is electric motors not rotating? Everything else is good.
- Electric common failures and troubleshooting methods instrument display is normal, motor does not turn the cause of the problem: (1) brake the damage judgment (2) speed control to turn the damage judgment damage judgment, (4) (3) motor controller damaged troubleshooting: (1) remove the brake handle socket (normally open type brake handle). If the motor operates, the brake should be replaced. Turn the source 5V voltage to normal, check the signal voltage, turn the transfer, the signal voltage should be in 0.8 ~ 4.2 V from low to high. If the voltage is not changed and is less than 1V, then the fault or turn will be short-circuited. If the voltage is greater than 1V and the change is normal, the signal (yellow, green and blue) is detected. If the voltage of the three-phase hall signal line is 5V and is in good contact, the motor hall is damaged and the motor or motor hall elements should be replaced.
- Q:Direct drive motor control mode
- So there is no such thing as "the frame type is the control mode of the permanent magnet synchronous motor, the no-frame type is the control mode of dc brushless motor". Perhaps your motor coincided with a particular type of "frame with permanent magnet synchronous motor control mode" or the different type of brushless dc motor control way ". In fact, permanent magnet synchronous motor control method and two kinds of brushless dc motor control method in most cases is one thing, there is not much difference.
- Q:Who is more powerful than the average motor and servo?
- Servo motor is controlled by the signals, whose output big and ordinary motor it makes no difference, but the difference on the startup mode, in the power phase at the same time, only a size to distinguish the size of the output torque of the motor.
- Q:What is the structural difference between a two-speed motor and a regular motor
- There are two sets of coils in the two-speed motor slot, and the ordinary motor has a set of coils through the special switch control speed. This is the main difference.
- Q:Does the motor swing around?
- The motor bearing is out of question, causing the left and right oscillation.I hope my answer will help you.
- Q:The difference between pulse motor and servo motor
- But if you ask the difference between the stepping motor and the ac servo or dc servo, I can tell you: Stepper motor start-up needs a slow speed, and can control through pulse, and is inversely proportional to the speed and torque of the motor, the higher the speed, torque is smaller, and the highest speed is not more than 1500 r and his itself has no feedback device, speed up the easy step, and the low speed easy to shake. And other kinds of motor position control (pulse) and speed (analog control) with a feedback device, constant torque under the rated speed, the speed of tens of thousands of turn, and because there are feedback device step will not be lost
- Q:What is the difference between a three-phase asynchronous motor and a regular motor?
- Three-phase asynchronous motor has high efficiency, energy saving, low noise, small vibration, and the advantages of reliable performance, can make using of the drive for different mechanical: such as fan, compressor, water pump, crusher, cutting machine and other equipment, and is available for coal mining, mechanical industry, power plants and various industrial and mining enterprises as a prime mover. Thank you for your reference. I hope I can help you.
- Q:The governor has changed a new one, with the governor to zero, but the motor is still turning! The motor has a different sound, such as the sound of iron and iron friction!
- Check the speed line. There may be a circuit breakers. There's no problem with the excitation coils. The motor is abnormal and the bearing is damaged.
- Q:In what situations does the step motor lose?
- Stepper motor lose step and positioning, usually caused by the following reasons: 1, change direction when pulse, were characterized by any one direction, but a change of direction is the cumulative deviation, the more and more wide; 2, the initial velocity is too high, the acceleration is too big, cause sometimes to lose step; Too much or too little to be compensated for in the synchronous belt. Not enough motor power; 5, the controller is disturbed to cause the wrong action. The drive is caused by interference; Software bugs. Want to be specific analysis?
- Q:Does the motor have a good brush or no brush?
- The carbon brush looks a bit like a pencil eraser, with a wire on top. There is a lot of small size. As a sliding contact, carbon brushes are widely used in many electrical devices. The products are made of graphite, lipographene, metal (copper, silver) graphite.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
50kva - 1500kva Electric Cummins Diesel Generator 6BT5.9G1
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords