Yasukawa inverter reported bb code that is the reason why the base blockade?
Not a drive failure! Is an external signal problem.
Can the inverter stop intermittently during operation? If so, how to connect and set up
and the corresponding function of these terminals, you have to in the inverter Set up.
Is the motor having a variable frequency motor and a variable voltage motor?
According to the way to start talking about a variable frequency motor and variable voltage motor
Inverter signal line analog 4-20mA connection positive and negative can be reversed?
Analog input signal is particularly vulnerable to external interference, so the general use of twisted shield as a signal line; and wiring as short as possible, generally not more than 20 meters; if some use conditions are vulnerable to external serious interference, the analog signal Side need to add a filter capacitor or ferrite core.
Taian inverter 3.7KW 380V with 4.0KW 2 pole motor 18000 to 300HZ can it?
The existing Taian inverter 380V3.7KW can bring 4.0KW 2 pole motor, 18000 to 300HZ can also see how you load, It is best to check your wiring tightness and whether the load is stuck. It is recommended to use the N310-4005-S3 this model, such as with the E510-405-H3 better.
Speed regulation method of three - phase asynchronous motor
This is the two-speed motor 1 will be the UI VI WI connected to the third phase of the remaining joint empty at this time for the four 2 U2 V2 W2 connected to the other three junctions at this time for the two levels This is the angle - there are many binary speed In addition there are three-speed motor in this no longer introduced The number of variable pole pairs can be varied, but the more variable the number of logarithmic materials Like a two-speed motor with a set of windings Three-speed motor has two sets of windings So the current single-board frequency conversion speed up
What is the motor series parameter setting of the inverter? If it is with the spindle,
The number of motor poles can be estimated by the parameters: 1000Hz corresponds to 60000rpm, According to "Speed in rpm = 60 * Frequency in Hz / (Number of Poles / 2)", Number of poles = 60 * Frequency indicated by Hz * 2 / Speed in rpm = 60 * 1000 * 2/60000 = 2 poles. The same is true with 333Hz and 20000rpm projections. The number of motor poles for the frequency converter should be entered with the number of poles of the motor that are directly connected to the frequency converter.
Pump frequency converter instantaneous restart and restart the problem
Speed tracking start, with them better. Speed search time is less than the free downtime, not too small too much, will be over-voltage protection. I do not understand and contact me. Your inverter voltage level, manufacturers.