Who knows how big transformers and lines the 36V transformer uses in lighting?
No matter how many volts the output / input voltage of the transformer is, the size and the amount of the core of the transformer, the wire diameter of the winding lead and the lead thickness must be determined by the transformer capacity. Example: input 220V, output 36V load is 36v/40w light bulb 6, so the primary needs 0.72, secondary use 1.81 diameter enameled wire winding system. The transformer capacity is about 250VA.
How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
The transformer zero line has broken, has the result to the household illumination circuit?
The power supply system in three-phase four line zero line is broken, the breakpoint of the single-phase circuit (220V) electrical burn by voltage to 380V. I met, the incandescent lamp suddenly particularly bright then the blow up of internal fuse TV has burned out. So in the three-phase four wire power supply system zero line asked to do repeat grounding in households is the reason.
Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
What's the function of the lighting transformer?
Illumination transformer: usually refers to the secondary output voltage for the safety voltage 24V - 36V, only for special lighting power supply using voltage converter.
Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
Does the lighting work properly? Doesn't that power equipment start voltage unstable?
Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.