What is the difference between AC and DC frequency converters?
L inverter air conditioner refrigeration system components: inverter air conditioner by the compressor, evaporator, condenser, electromagnetic four-way valve, electronic expansion valve, defrost valve, double capillary and other components (see Figure II), work, air conditioner Room needs, automatic control of the inverter output frequency higher AC, the motor speed to speed up, the compressor cooling capacity increased to achieve the purpose of rapid cooling or heating, on the contrary, when the room cooling or heating less, Compressor to normal speed or lower speed operation, therefore, inverter air conditioner has a continuous cooling capacity adjustment, making the room temperature fluctuations smaller. In the process of compressor operation, the microcomputer system controls the inverter compressor at the same time, controls the opening degree of the electronic expansion valve, maintains the proper refrigerant flow, and directly changes the flow of the refrigerant in the evaporator to change its state, the compressor The speed corresponds to the opening degree of the expansion valve, and the displacement of the compressor corresponds to the supply amount of the expansion valve, so that the degree of superheat is not so large that the capacity of the evaporator is maximized, so that the refrigeration system The most efficient control.
Is the inverter output current proportional to the output torque?
When 50HZ or more, the voltage is not increased, the magnetic flux decreases. P = T * n / 9550, if the motor output torque does not change, the current will increase, the motor heat overload
Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
n the motor pole, an Antarctic (S pole), an Arctic (N pole), calculate a pair of poles, the number of pole pairs is how many such "pairs" (S pole + N pole). 2 pole motor --- pole pairs 1 = P = 1,4 pole motor --- pole pairs 2 = P = 2, and so on.
A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
The upper limit frequency transferred to 25HZ, the number of poles changed to 2, try to run when the motor speed test
Is the laptop power adapter hot?
Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.
Inverter 0.2KW, the motor speed requirements down to 4 turn, the motor pole 4 pole. Can the drive drive the motor?
Can, but this is a test product, the application does not try!
How does the variable frequency motor output torque at very low frequencies?
50hz the following frequency, u constant, current and frequency is proportional to the frequency down the output current is also down, and torque and current is proportional to the natural torque is small
Does the inverter set the number of poles to match the number of poles of the motor?
The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.